Sources we rely on for our guides: national metrology institutes, ISO standards, industry associations and journal papers on dew point, natural gas quality, refining process gas, CO₂ and oxygen. Each entry has a one-line note on what it covers.

Dew point and humidity

  1. A guide to the measurement of humidity (Good Practice Guide 103)National Physical Laboratory (NPL), UK, 1996. The UK national measurement institute's good practice guide for people who use humidity instruments.
  2. The beginner's guide to humidity measurement (Good Practice Guide 124)National Physical Laboratory (NPL), UK, 2013. Introduces the concept of humidity and the basics of making a reliable humidity measurement.
  3. Chilled-mirror hygrometerAmerican Meteorological Society, Glossary of Meteorology. Defines the instrument: a mirror is cooled until condensation scatters the reflected light, and electronics hold it at the dew point; accurate, with a slower response.
  4. Hygrometers: calibration serviceNIST Thermodynamic Metrology Group. NIST calibrates chilled-mirror hygrometers in dew/frost point from −90 °C to +85 °C against its Hybrid Humidity Generator.
  5. Calibration of Hygrometers with the Hybrid Humidity Generator (NIST SP 250-83r1)C. W. Meyer, T. Herman, W. W. Miller, NIST, 2021. Describes the US national humidity standard and its uncertainty budget; chilled-mirror hygrometers serve as transfer standards in its international comparisons.
  6. Bilateral key comparison SIM.T-K6.5 on humidity standards in the dew/frost-point temperature range from −30 °C to +20 °CC. W. Meyer (NIST), A. Solano (LACOMET), Metrologia 53, Tech. Suppl. 03005, 2016. Two national laboratories compared their dew/frost-point standards using a chilled-mirror hygrometer shipped between them as the transfer standard; results agreed within uncertainty.
  7. Sensitivity Enhancement of a PPM Level Capacitive Moisture SensorL. Kumar, T. Islam, S. C. Mukhopadhyay, Electronics 6(2):41, 2017. Open-access paper on a porous aluminium-oxide capacitive sensor for 3 to 100 ppm moisture in process gases, the sensing principle behind metal-oxide dew point meters.

Natural gas: water dew point

  1. ISO 6327:1981 Gas analysis — Determination of the water dew point of natural gas — Cooled surface condensation hygrometersInternational Organization for Standardization, 1981. The standard for measuring natural-gas water dew point with chilled-mirror (cooled-surface) hygrometers; confirmed as current in 2024.
  2. ISO 18453:2004 Natural gas — Correlation between water content and water dew pointInternational Organization for Standardization, 2004. Gives a method to convert between water content and water dew point in natural gas; confirmed as current in 2024.
  3. An investigation of the comparative performance of diverse humidity sensing techniques in natural gasJ. G. Gallegos, R. Benyon et al. (European metrology project team), Journal of Natural Gas Science and Engineering 23:407–416, 2015. Eleven hygrometers of different principles tested in natural gas at 0.1 to 6 MPa and 13 to 250 ppmv water; most performed well, while most aluminium-oxide probes drifted.

Natural gas: hydrocarbon dew point

  1. Comparison of methods for the measurement of hydrocarbon dew point of natural gas (NPL Report AS 3)A. Brown, M. Milton et al., National Physical Laboratory (NPL), UK, 2007. Compares direct chilled-mirror instruments with gas-chromatography calculations on synthetic and real gases; concludes that reported hydrocarbon dew points should state the method used.
  2. ISO/TR 12148:2009 Natural gas — Calibration of chilled mirror type instruments for hydrocarbon dewpoint (liquid formation)International Organization for Standardization, 2009. Requirements for traceable calibration of automated chilled-mirror hydrocarbon dew point instruments; confirmed as current in 2024.
  3. ISO 23874:2006 Natural gas — Gas chromatographic requirements for hydrocarbon dewpoint calculationInternational Organization for Standardization, 2006. Sets the gas-chromatograph performance (C5 to C12) needed to calculate pipeline-gas hydrocarbon dew point with an equation of state.

Natural gas quality

  1. ISO 13686:2013 Natural gas — Quality designationInternational Organization for Standardization, 2013. Defines the parameters used to describe the quality of processed natural gas; confirmed as current in 2025.
  2. ISO 6976:2016 Natural gas — Calculation of calorific values, density, relative density and Wobbe indices from compositionInternational Organization for Standardization, 2016. Calculation methods for heating value, density and Wobbe index from the molar composition of the gas.
  3. ISO 10715:2022 Natural gas — Gas samplingInternational Organization for Standardization, 2022. How to take natural-gas samples that truly represent the gas being measured, for dry transmission and distribution gas.
  4. Characterisation of Energy Gases (EMRP project ENG01)EURAMET, coordinated by NPL with 17 national metrology institutes, 2010–2013. European metrology project on calorific value, gas composition, trace impurities and humidity measurement at high pressure in natural gas and non-conventional gases.

Refining: process gas measurement points

  1. Petroleum Refining Process (OSHA Technical Manual, Section IV, Chapter 2)US Occupational Safety and Health Administration. Overview of the main refinery units (distillation, cracking, alkylation, catalytic reforming, hydrotreating) where process gases are sampled and analysed.
  2. What is the importance of water content in reformer feed and recycle gas on the performance of the catalyst? (Q&A)American Fuel & Petrochemical Manufacturers (AFPM), technical Q&A, 2017. Refining practitioners explain why water in catalytic-reformer feed and recycle gas must be measured and controlled, with target levels in ppm.
  3. Operating parameters, including water or chloride additions, on a CCR reforming unit (Q&A)American Fuel & Petrochemical Manufacturers (AFPM), technical Q&A, 2011. Refiners report recycle-gas moisture of about 15 to 35 ppm and a target near 20 ppmv to keep the water–chloride balance of the reforming catalyst.
  4. Moving Forward as On-Line Analyzers Improve (paper 24e)AIChE Spring Meeting & Global Congress on Process Safety, 2014. How online analyzers for hydrogen, moisture and combustion improve control and product consistency in refining.

Compressed air

  1. ISO 8573-1:2010 Compressed air — Part 1: Contaminants and purity classesInternational Organization for Standardization, 2010. The standard that defines compressed-air purity classes, including water expressed as pressure dew point.

CO₂ (NDIR)

  1. Nondispersive infrared sensorWikipedia. General overview of NDIR: broadband infrared light, an optical filter at the gas's absorption band (4.26 µm for CO₂) and a reference path.
  2. Carbon Dioxide Sensor Module Based on NDIR TechnologyL. Zhou, Y. He, Q. Zhang, L. Zhang, Micromachines 12(7):845, 2021. Open-access paper on a dual-channel NDIR CO₂ module, with temperature and humidity compensation of the detector signals.

Oxygen measurement

  1. Electro-galvanic oxygen sensorWikipedia. Explains the galvanic cell: oxygen is reduced at the cathode, a diffusion barrier makes the current proportional to oxygen partial pressure, and the anode is slowly consumed.
  2. Optical methods for sensing and imaging oxygen: materials, spectroscopies and applicationsX. Wang, O. S. Wolfbeis, Chemical Society Reviews 43:3666–3761 (open access), 2014. Open-access review of optical oxygen sensing (absorption, luminescence quenching) as an alternative to electrochemical cells.

External sources open on the publisher's website. YORK Instrument is not affiliated with them. Links checked on 17 October 2026.

Each process measurement-point map lists its own references for the limits it shows.