Conversion · frost point
−20 °C frost point in ppm
At atmospheric pressure, a frost point of −20 °C means the gas contains 1,019 ppmV of water vapour. Below are the same value in mass units and natural gas units, and what it becomes at line pressure.
At a glance
1,019 ppmV
Water content of a gas with a frost point of −20 °C, measured or expressed at atmospheric pressure (1.013 bar).
| Quantity | Value |
|---|---|
| Water content (by volume) | 1,019 ppmV |
| In air (by mass) | 634 ppmW |
| In nitrogen (by mass) | 655 ppmW |
| Mass concentration, 0 °C reference | 819 mg/Nm³ |
| Mass concentration, 15 °C reference | 776 mg/Sm³ |
| Natural gas units | 48.4 lb/MMscf |
| Water vapour pressure | 103 Pa |
Vapour pressure from the Sonntag (1990) equations over ice; no enhancement factor. Results are the same as the dew point calculator with default settings.
The same gas at line pressure
Compressing a gas raises its dew point, because the water vapour partial pressure rises with the total pressure. A gas with 1,019 ppmV of water has these pressure dew points:
| Line pressure | Pressure dew point | ISO 8573-1 water class (compressed air) |
|---|---|---|
| 4 bar(g) | −2.2 °C frost point | Class 4 |
| 7 bar(g) | +4.1 °C dew point | Class 5 |
| 10 bar(g) | +8.7 °C dew point | Class 6 |
| 20 bar(g) | +18.6 °C dew point | — |
| 50 bar(g) | +33.6 °C dew point | — |
The other way round: if −20 °C is the pressure dew point at 7 bar(g), for example from a compressed air dryer, the gas contains about 129 ppmV of water and its atmospheric frost point is about −39.9 °C.
Frost point or dew point? Below 0 °C, water condenses as frost, and −20 °C here is a frost point. If an instrument reports the dew point over supercooled water instead, the same water content reads as about −22.3 °C dew point. Check which convention your analyzer and your specification use before comparing numbers.
Moderately dry gas
Typical of instrument and plant air in many facilities, membrane dryers, and natural gas after glycol dehydration when the dew point is expressed at atmospheric pressure. Metal-oxide transmitters and portable meters cover this range easily.
Metal-oxide transmitters and portable meters (YORK DPT series) cover this value for process and field use; a chilled mirror hygrometer is the usual reference for calibration in safe areas with non-flammable gases.
See also the full dew point to ppm table and calculator, the ISO 8573-1 air class checker and the moisture unit converter.
Need to measure it?
YORK metal-oxide dew point transmitters and portable meters measure from −110 °C frost point to +20 °C dew point; chilled mirror hygrometers down to −90 °C frost point serve as references. Tell us the gas, the expected dew point and the pressure, and our Dubai team will propose a model.