ISO 8573-1 compressed air class checker

Enter a dew point reading, where it was measured, and your line pressure. The tool converts it to pressure dew point and tells you which ISO 8573-1 water class your air meets.

↧ Download offline version (single HTML file, works without internet)

LiveYORK · Air quality class

For example at the outlet of a portable meter after pressure reduction

Pressure dew point
—°C
ISO 8573-1 water class
—
Water content
—ppmV
—
Where your air sits on the ISO 8573-1 scale
    Atmospheric dew point
    —
    Reading at the sensor
    —
    mg/m³ (0 °C)
    —
    Water vapour pressure
    —
    Send these parameters to an engineer →Opens the enquiry form with your inputs filled in.

    ISO 8573-1:2010 water classes

    ISO 8573-1 grades compressed air for particles, water and oil, written as [A:B:C]. This tool covers the middle figure, water. Classes 1 to 6 are set by the pressure dew point, which is the dew point at the pressure of the air in the system, not at atmosphere.

    ClassPressure dew pointLiquid water content
    0As specified by the user or supplier, stricter than class 1
    1≤ −70 °C–
    2≤ −40 °C–
    3≤ −20 °C–
    4≤ +3 °C–
    5≤ +7 °C–
    6≤ +10 °C–
    7–≤ 0.5 g/m³
    8–0.5 to 5 g/m³
    9–5 to 10 g/m³
    X–> 10 g/m³

    Why the measuring pressure matters

    The same air shows a lower dew point when its pressure drops. Air at −40 °C pressure dew point in a 7 bar(g) system reads about −57 °C at atmospheric pressure. If a portable meter samples through a pressure reducer, its reading must be converted back to line pressure before you compare it with ISO 8573-1, otherwise the air looks one class better than it is.

    Method and limits

    • Water vapour pressure from Sonntag (1990), over ice below 0 °C unless you choose dew point over water; ideal gas mixing.
    • Particle and oil classes are measured with other methods (ISO 8573-4, ISO 8573-2 and -5) and are not covered here. Humidity test methods are given in ISO 8573-3.
    • Classes 7 to 9 are defined by liquid water content, which a dew point instrument does not measure.

    Frequently asked questions

    What dew point is ISO 8573-1 class 2?

    Class 2 is a pressure dew point of −40 °C or lower, measured at the pressure of the compressed air system. For a 7 bar(g) system this corresponds to about −57 °C at atmospheric pressure.

    Is the ISO 8573-1 dew point measured at line pressure?

    Yes. Classes 1 to 6 are defined by pressure dew point. A reading taken at a different pressure, for example after a pressure reducer, has to be converted to line pressure before the class is assigned.

    What dew point does instrument air need?

    ANSI/ISA-7.0.01 asks for a dew point at line pressure at least 10 °C below the lowest temperature any part of the instrument air system is exposed to. Many plants specify ISO 8573-1 class 2 (−40 °C) to cover this with margin.

    Checking a dryer or an air network?

    We can supply online dew point transmitters, portable meters and chilled mirror references for compressed air audits.