1. Home
  2. Guides
  3. Dew point to ppm
  4. +10 °C

Conversion · dew point

+10 °C dew point in ppm

At atmospheric pressure, a dew point of +10 °C means the gas contains 12,121 ppmV of water vapour. Below are the same value in mass units and natural gas units, and what it becomes at line pressure.

At a glance

12,121 ppmV

Water content of a gas with a dew point of +10 °C, measured or expressed at atmospheric pressure (1.013 bar).

QuantityValue
Water content (by volume)12,121 ppmV
In air (by mass)7,540 ppmW
In nitrogen (by mass)7,795 ppmW
Mass concentration, 0 °C reference9,742 mg/Nm³
Mass concentration, 15 °C reference9,235 mg/Sm³
Natural gas units575 lb/MMscf
Water vapour pressure1,228 Pa

Vapour pressure from the Sonntag (1990) equations over water; no enhancement factor. Results are the same as the dew point calculator with default settings.

The same gas at line pressure

Compressing a gas raises its dew point, because the water vapour partial pressure rises with the total pressure. A gas with 12,121 ppmV of water has these pressure dew points:

Line pressurePressure dew pointISO 8573-1 water class (compressed air)
4 bar(g)+36.4 °C dew point—
7 bar(g)+45.2 °C dew point—
10 bar(g)+51.6 °C dew point—
20 bar(g)+65.4 °C dew point—
50 bar(g)+86.7 °C dew point—

The other way round: if +10 °C is the pressure dew point at 7 bar(g), for example from a compressed air dryer, the gas contains about 1,533 ppmV of water and its atmospheric frost point is about −15.7 °C.

Humid gas

Above the usual compressed air dryer range. Water can condense wherever the gas meets a surface colder than its dew point, for example in pipework exposed to air conditioning or at night.

Metal-oxide transmitters and portable meters (YORK DPT series) cover this value for process and field use; a chilled mirror hygrometer is the usual reference for calibration in safe areas with non-flammable gases.

See also the full dew point to ppm table and calculator, the ISO 8573-1 air class checker and the moisture unit converter.

Need to measure it?

YORK metal-oxide dew point transmitters and portable meters measure from −110 °C frost point to +20 °C dew point; chilled mirror hygrometers down to −90 °C frost point serve as references. Tell us the gas, the expected dew point and the pressure, and our Dubai team will propose a model.