Natural gas water content calculator
Convert between water dew point and water content in lb/MMscf, mg/Sm³ or ppmV at your pipeline pressure. See the dew point at a second pressure, and check the result against a specification limit.
- mg/Sm³ (15 °C)
- —
- ppmV
- —
- Ideal-gas estimate
- —
- Dew point at 1 atm
- —
Quick reference: pipeline water content and dew point
Saturated water content of lean, sweet natural gas, calculated with the same Bukacek correlation as the calculator above. Values below about 15 °C are extrapolated, so treat them as engineering estimates.
| lb/MMscf | mg/Sm³ | ppmV | Water dew point at 50 bar(a) | Water dew point at 70 bar(a) |
|---|---|---|---|---|
| 2 | 32.1 | 42 | −20 °C | −18 °C |
| 4 | 64.2 | 84 | −11 °C | −8 °C |
| 7 | 112 | 147 | −3 °C | +0.5 °C |
| 10 | 160 | 211 | +3 °C | +6 °C |
| 20 | 321 | 421 | +14 °C | +18 °C |
7 lb/MMscf is a common limit in North American pipeline tariffs, and 4 lb/MMscf is used where a drier gas is required. The European EASEE-gas recommendation of −8 °C at 70 bar(a) corresponds to about 4 lb/MMscf (64 mg/Sm³). In the Gulf, the limit is set by the gas sales or transportation agreement, often as a water dew point at a stated pressure: enter that pressure above to compare.
Method
Water content is calculated with the Bukacek correlation, the method behind the familiar McKetta–Wehe chart in the GPSA Engineering Data Book:
W = 47,484 · pv / P + B, log10B = −3,083.87 / (T + 459.6) + 6.69449
with W in lb/MMscf (60 °F, 14.696 psia), T in °F, P and the water vapour pressure pv in psia. The first term is the ideal-gas (Raoult) part. The second term, B, accounts for the extra water that real gas holds at high pressure. At 70 bar it makes up a large share of the total, so an ideal-gas conversion would understate the water content considerably.
Units: 1 lb/MMscf = 21.06 ppmV = 16.0 mg/Sm³ (15 °C, 101.325 kPa).
Limits
- For lean, sweet natural gas. CO₂ and H₂S raise the water content; heavy hydrocarbons and glycol carry-over change it too.
- The correlation was fitted above about 15 °C. Pipeline water dew points are usually lower, so results there are extrapolations.
- For custody transfer use ISO 18453 (GERG-water) with the actual gas composition, or measure the water dew point directly.
Measuring water in natural gas
On a chilled mirror, heavy hydrocarbons can condense before water and give a false reading. Metal-oxide sensors respond to water only and are the usual online choice, with a sampling system that reduces pressure, filters liquids and keeps the line above the hydrocarbon dew point.
Frequently asked questions
How do I convert lb/MMscf to water dew point?
You need the pressure. 7 lb/MMscf corresponds to a water dew point of about 0 °C at 1,000 psia (69 bar), but much lower at lower pressure. This calculator uses the Bukacek correlation to convert at any pressure from 1 to 700 bar.
How many ppmV is 1 lb/MMscf?
1 lb/MMscf of water is about 21.06 ppmV, or about 16 mg/Sm³ at 15 °C and 101.325 kPa.
Why is natural gas water content higher than the ideal-gas value?
At high pressure real natural gas holds more water vapour than Raoult’s law predicts. The Bukacek correlation adds a correction term for this. At pipeline pressures the difference can be large.
What water dew point is 7 lb/MMscf?
About 0 °C at 70 bar(a) (1,000 psia) and about −3 °C at 50 bar(a), using the Bukacek correlation. The lower the pressure, the lower the dew point for the same water content.
How many mg/Sm³ is 7 lb/MMscf?
About 112 mg/Sm³ at 15 °C and 101.325 kPa, or about 147 ppmV.
More engineering tools
- Dew point calculatorConvert pressure dew point to atmospheric dew point, ppmV, mg/m³ and lb/MMscf, with a pipe condensation check.
- ISO 8573-1 air class checkerFind the ISO 8573-1 water class of your compressed air from a dew point reading at any pressure.
- Analyzer selectorAnswer five questions and get the YORK moisture, oxygen or CO₂ analyzer that fits your application.
- Nitrogen purge calculatorHow long, and how much nitrogen, to purge a vessel or pipeline down to a target O₂ level.
- SF₆ moisture calculatorConvert SF₆ dew point to ppmV and mg/kg, find the dew point at filling pressure and check IEC limits.
- Hydrogen purity checker (ISO 14687)Check water, oxygen and other impurities against ISO 14687 Grade D for fuel-cell hydrogen.
- Sample line response timeTransport time and T95 response for a gas sample line, from tubing size, length, flow and pressure.
- Moisture and oxygen unit converterppmV, ppmW, mg/m³, mg/Sm³, lb/MMscf and dew point for moisture; %, ppm, ppb and partial pressure for oxygen.