Free tool · Selection
Which analyzer do I need?
Five questions about what you measure, how dry the gas is, where it is installed and whether the area is hazardous. You get a shortlist of YORK instruments and can send your answers to our engineers in one click.
↧ Download offline version (single HTML file, works without internet)
- DM9600PPortable chilled mirror hygrometer
- DM9600PLPortable chilled mirror hygrometer
- DPT-600 PlusPortable dew point meter
- DM9200Chilled mirror hygrometer with insertion probe
- DPT830In-line dew point analyzer
- DPT810Dew point transmitter
- DM9600Benchtop chilled mirror hygrometer
- DM9700Rack-mount chilled mirror hygrometer
- DM9800Rack-mount chilled mirror hygrometer
- DM9900Rack-mount chilled mirror hygrometer, reference grade
- DPT990-EXExplosion-proof dew point analyzer
- DPSS-61XXGas sampling and conditioning system
- POA200Portable trace oxygen analyzer
- PGA500In-line trace oxygen analyzer
- PGA500-EXExplosion-proof trace oxygen analyzer
- POA3500Portable oxygen analyzer
- POA300Portable percent oxygen analyzer
- PGA530In-line percent oxygen analyzer
- PGA620Portable CO₂ analyzer
- PGA520In-line CO₂ analyzer
- YKDC220Dew point calibration system
- DC2000Low humidity generator
- DC1000Dry gas generator
Process maps · animated
Find your measurement point on a process map
Animated flow sheets for 24 processes. Each shows the measurement points for moisture, O₂ and CO₂, the typical limits, and the analyzer that fits.
Moisture H₂OOxygen O₂CO₂Other analyses
How the selector chooses
- Range first. Each recommendation covers the driest dew point or lowest oxygen level you expect, with margin.
- Chilled mirror or metal oxide. Chilled mirror instruments measure the dew point directly and suit reference work and audits. Metal-oxide sensors reach −110 °C frost point, respond quickly and suit continuous monitoring and natural gas.
- Electrochemical or paramagnetic. Electrochemical cells reach trace levels (ppm). Paramagnetic sensors suit percent levels and have no consumable cell.
- Hazardous areas. Explosion-proof versions are listed where available. Certification documents are provided per model.
The shortlist is a starting point. Sample conditions such as pressure, temperature, contaminants and flow decide the final configuration, so send us your answers and we will confirm.
Frequently asked questions
Should I choose a chilled mirror or a metal-oxide dew point meter?
Choose a chilled mirror when you need a fundamental, traceable measurement, for example as a reference or for audits. Choose a metal-oxide sensor for continuous monitoring, very dry gases down to −110 °C frost point, or natural gas where hydrocarbons can condense on a mirror.
Which oxygen sensor is right for trace levels?
For ppm-level oxygen in nitrogen, argon or other inert gases, an electrochemical trace oxygen analyzer is the usual choice. YORK trace oxygen analyzers cover 0.01 ppm to 25 % O₂.
Do you have explosion-proof analyzers?
Yes, explosion-proof versions are available for dew point and trace oxygen. Certification documents are provided per model, so tell us the zone, gas group and temperature class.
More engineering tools
- Dew point calculatorConvert pressure dew point to atmospheric dew point, ppmV, mg/m³ and lb/MMscf, with a pipe condensation check.
- ISO 8573-1 air class checkerFind the ISO 8573-1 water class of your compressed air from a dew point reading at any pressure.
- Nitrogen purge calculatorHow long, and how much nitrogen, to purge a vessel or pipeline down to a target O₂ level.
- Natural gas water content calculatorConvert water dew point at line pressure to lb/MMscf, mg/Sm³ and ppmV, and check against a pipeline specification.
- SF₆ moisture calculatorConvert SF₆ dew point to ppmV and mg/kg, find the dew point at filling pressure and check IEC limits.
- Hydrogen purity checker (ISO 14687)Check water, oxygen and other impurities against ISO 14687 Grade D for fuel-cell hydrogen.
- Sample line response timeTransport time and T95 response for a gas sample line, from tubing size, length, flow and pressure.
- Moisture and oxygen unit converterppmV, ppmW, mg/m³, mg/Sm³, lb/MMscf and dew point for moisture; %, ppm, ppb and partial pressure for oxygen.
Not sure which one fits?
Send us the gas, pressure, range and installation details. Our Dubai-based contact will come back with a configured proposal.