Free tool · Hydrogen
Hydrogen purity checker for ISO 14687:2025 Grade D
Enter your measured water and oxygen, and any lab results you have for other impurities. The tool checks each one against ISO 14687 Grade D, the specification for hydrogen used in PEM fuel cell vehicles.
↧ Download offline version (single HTML file, works without internet)
| Component | Limit | Measured | Of limit | |
|---|---|---|---|---|
| H₂O Water | ≤ 5 | |||
| O₂ Oxygen | ≤ 5 | |||
| THC Hydrocarbons except methane, incl. formic acid (C1 basis) | ≤ 2 | |||
| CH₄ Methane | ≤ 100 | |||
| He Helium | ≤ 300 | |||
| N₂ Nitrogen | ≤ 300 | |||
| Ar Argon | ≤ 300 | |||
| CO₂ Carbon dioxide | ≤ 2 | |||
| CO Carbon monoxide | ≤ 0.2 | |||
| S Total sulfur compounds (S1 basis) | ≤ 0.004 | |||
| HCHO Formaldehyde | ≤ 0.2 | |||
| NH₃ Ammonia | ≤ 0.1 | |||
| Hal. Halogenated compounds (halide ion basis) | ≤ 0.05 |
- Frost point at 1 atm
- —
- Frost point at storage pressure
- —
- Water limit at 1 atm
- —
- Total non-hydrogen gases
- —
ISO 14687 Grade D at a glance
ISO 14687:2025 (second edition, February 2025) sets hydrogen quality by application. Grade D covers hydrogen for PEM fuel cells in road vehicles and is the grade most hydrogen refuelling stations work to. The minimum hydrogen fuel index is 99.97 %, the total of non-hydrogen gases is limited to 300 µmol/mol, and the sum of CO and HCHO must not exceed 0.2 µmol/mol. Since the 2025 edition, formic acid is counted within hydrocarbons except methane rather than listed separately.
Water and oxygen are both limited to 5 µmol/mol; water may be 7 µmol/mol at stations dispensing only at 35 MPa with precooling at −26 °C or warmer. See ISO 14687:2025 explained for all grades and what changed. 5 µmol/mol of water corresponds to a frost point of about −65.5 °C at atmospheric pressure, so the measurement needs an instrument that reads reliably in that range.
What the tool does not cover
- Particulates (limit 1 mg/kg) and the full component list need laboratory analysis; ISO 21087 describes the analytical methods.
- The hydrogen fuel index here is estimated from the components you enter. Missing components make it look better than it is.
- Frost point at storage pressure uses ideal mixing and is approximate at hundreds of bar.
Measuring water and oxygen in hydrogen
For electrolysers and refuelling stations, metal-oxide dew point sensors cover the low ppm water range and trace oxygen analyzers cover oxygen from 0.01 ppm. Hydrogen areas are usually hazardous, so explosion-proof versions are often required.
Frequently asked questions
What are the water and oxygen limits in ISO 14687 Grade D?
Both are 5 µmol/mol (ppm by volume); under ISO 14687:2025 water may be 7 µmol/mol for stations dispensing only at 35 MPa with precooling at −26 °C or warmer. Grade D also requires a hydrogen fuel index of at least 99.97 % and limits total non-hydrogen gases to 300 µmol/mol.
What dew point is 5 ppm water in hydrogen?
About −65.5 °C frost point at atmospheric pressure. At storage pressure the frost point of the same gas is much higher, so always state the pressure with a dew point.
Can I check full ISO 14687 compliance with online analyzers?
Online analyzers are well suited to continuous water and oxygen monitoring. Full Grade D compliance covers many more components at very low levels and is confirmed by laboratory analysis according to ISO 21087.
More engineering tools
- Dew point calculatorConvert pressure dew point to atmospheric dew point, ppmV, mg/m³ and lb/MMscf, with a pipe condensation check.
- ISO 8573-1 air class checkerFind the ISO 8573-1 water class of your compressed air from a dew point reading at any pressure.
- Analyzer selectorAnswer five questions and get the YORK moisture, oxygen or CO₂ analyzer that fits your application.
- Nitrogen purge calculatorHow long, and how much nitrogen, to purge a vessel or pipeline down to a target O₂ level.
- Natural gas water content calculatorConvert water dew point at line pressure to lb/MMscf, mg/Sm³ and ppmV, and check against a pipeline specification.
- SF₆ moisture calculatorConvert SF₆ dew point to ppmV and mg/kg, find the dew point at filling pressure and check IEC limits.
- Sample line response timeTransport time and T95 response for a gas sample line, from tubing size, length, flow and pressure.
- Moisture and oxygen unit converterppmV, ppmW, mg/m³, mg/Sm³, lb/MMscf and dew point for moisture; %, ppm, ppb and partial pressure for oxygen.
Building an electrolyser or a hydrogen station?
We supply dew point and trace oxygen analyzers for hydrogen, including explosion-proof versions. Send us your process conditions.