CO₂ · CO₂
YORK PGA520 in-line CO₂ analyzer
The PGA520 is an in-line NDIR CO₂ analyzer with selectable ranges from 0–5000 ppm to 0–100% CO₂. It is used for continuous CO₂ measurement at percent level in capture, recovery and gas mixing systems, and for low-range checks such as CO₂ in breathing and medical air, in safe areas.

| Model | PGA520 |
|---|---|
| Type | In-line CO₂ analyzer |
| Principle | NDIR infrared |
| Ranges | 0–5000 ppm, 0–5%, 0–20%, 0–30%, 0–50% or 0–100% CO₂ (selectable) |
| Linearity | ±2% of full scale (excluding calibration gas uncertainty) |
| Repeatability | ±1% of full scale |
| Outputs | Analog output, digital output, alarm relay |
| Power | AC or DC supply |
| Areas | Safe areas only; there is no explosion-proof version |
| Lead time | 6 to 8 weeks |
| Warranty | 12 months from shipment |
| Regional contact | Dubai, UAE — covers the GCC |
Product catalog (PDF) · certificate copies are sent with quotations.
Where it is used
| Application | Typical range |
|---|---|
| CO₂ capture and compression | Percent CO₂ in process streams; see CO₂ capture measurement points |
| Gas mixing for modified atmosphere packaging | Percent CO₂ in N₂–CO₂ mixtures |
| CO₂ recovery plants | Percent CO₂ at process points |
| Breathing and medical air | Low CO₂, for example ≤500 ppm, with the 0–5000 ppm range |
Choosing the range
- Pick the smallest range that covers the expected value; accuracy is stated as a percentage of full scale.
- The PGA520 is not used for trace CO₂ specifications of 50 ppm or lower, such as LNG pre-treatment or hydrogen fuel quality; these need a dedicated trace CO₂ analyzer.
- It is not used to certify the purity of high-purity CO₂.
- Install it in a safe area; for hazardous areas, bring the sample to an analyzer shelter or use an integrated certified system.
PGA520 or another YORK analyzer?
| If you need… | Choose |
|---|---|
| Continuous CO₂ in a safe area | PGA520 |
| Portable CO₂ checks | PGA620 |
| Oxygen in gas containing CO₂ | POA3500 paramagnetic |
Ordering in the UAE and GCC
Send your enquiry to our Dubai team with:
- the gas and where it is measured;
- the CO₂ range you need;
- whether the point is in a hazardous area (the PGA520 and PGA620 are for safe areas);
- quantity.
We reply with a quotation for the PGA520. Instruments are shipped from the factory with export documents, 6 to 8 weeks from order confirmation. Tell us the range so we can quote the right sensor.
Questions about the PGA520
What ranges does the PGA520 offer?
0–5000 ppm, 0–5%, 0–20%, 0–30%, 0–50% or 0–100% CO₂.
What is the accuracy of the PGA520?
Linearity ±2% of full scale, excluding calibration gas uncertainty, and repeatability ±1% of full scale.
Can the PGA520 measure CO₂ below 50 ppm?
It is not recommended for specifications of 50 ppm or lower; use a dedicated trace CO₂ analyzer.
Is there an explosion-proof PGA520?
No. The PGA520 and PGA620 are for safe areas only.
How do I get a quotation in the UAE?
Email dubai@yorkinstrument.com or WhatsApp +971 55 137 4866 with the gas, CO₂ range and quantity.