CO₂ · CO₂

YORK PGA520 in-line CO₂ analyzer

The PGA520 is an in-line NDIR CO₂ analyzer with selectable ranges from 0–5000 ppm to 0–100% CO₂. It is used for continuous CO₂ measurement at percent level in capture, recovery and gas mixing systems, and for low-range checks such as CO₂ in breathing and medical air, in safe areas.

YORK PGA520 – In-line CO₂ analyzer
ModelPGA520
TypeIn-line CO₂ analyzer
PrincipleNDIR infrared
Ranges0–5000 ppm, 0–5%, 0–20%, 0–30%, 0–50% or 0–100% CO₂ (selectable)
Linearity±2% of full scale (excluding calibration gas uncertainty)
Repeatability±1% of full scale
OutputsAnalog output, digital output, alarm relay
PowerAC or DC supply
AreasSafe areas only; there is no explosion-proof version
Lead time6 to 8 weeks
Warranty12 months from shipment
Regional contactDubai, UAE — covers the GCC

Product catalog (PDF) · certificate copies are sent with quotations.

Where it is used

ApplicationTypical range
CO₂ capture and compressionPercent CO₂ in process streams; see CO₂ capture measurement points
Gas mixing for modified atmosphere packagingPercent CO₂ in N₂–CO₂ mixtures
CO₂ recovery plantsPercent CO₂ at process points
Breathing and medical airLow CO₂, for example ≤500 ppm, with the 0–5000 ppm range

Choosing the range

  • Pick the smallest range that covers the expected value; accuracy is stated as a percentage of full scale.
  • The PGA520 is not used for trace CO₂ specifications of 50 ppm or lower, such as LNG pre-treatment or hydrogen fuel quality; these need a dedicated trace CO₂ analyzer.
  • It is not used to certify the purity of high-purity CO₂.
  • Install it in a safe area; for hazardous areas, bring the sample to an analyzer shelter or use an integrated certified system.

PGA520 or another YORK analyzer?

If you need…Choose
Continuous CO₂ in a safe areaPGA520
Portable CO₂ checksPGA620
Oxygen in gas containing CO₂POA3500 paramagnetic

Ordering in the UAE and GCC

Send your enquiry to our Dubai team with:

  • the gas and where it is measured;
  • the CO₂ range you need;
  • whether the point is in a hazardous area (the PGA520 and PGA620 are for safe areas);
  • quantity.

We reply with a quotation for the PGA520. Instruments are shipped from the factory with export documents, 6 to 8 weeks from order confirmation. Tell us the range so we can quote the right sensor.

Questions about the PGA520

What ranges does the PGA520 offer?

0–5000 ppm, 0–5%, 0–20%, 0–30%, 0–50% or 0–100% CO₂.

What is the accuracy of the PGA520?

Linearity ±2% of full scale, excluding calibration gas uncertainty, and repeatability ±1% of full scale.

Can the PGA520 measure CO₂ below 50 ppm?

It is not recommended for specifications of 50 ppm or lower; use a dedicated trace CO₂ analyzer.

Is there an explosion-proof PGA520?

No. The PGA520 and PGA620 are for safe areas only.

How do I get a quotation in the UAE?

Email dubai@yorkinstrument.com or WhatsApp +971 55 137 4866 with the gas, CO₂ range and quantity.