Compare models
| Model | Type | Measuring range | Key features |
|---|---|---|---|
| DPSS-61XX | Gas sampling and conditioning system | On request | Sample conditioning for analyzers, built to project requirements |
| Analyzer panels | Moisture and gas analyzers integrated on a panel, to project scope | On request | Moisture, O₂ and CO₂ analyzers integrated on one panel |
Source: YORK Instrument product information, October 2026. Full specifications: product catalog (PDF).
How it works
Reliable moisture and oxygen readings depend as much on the sample system as on the analyzer. YORK supplies sample conditioning systems (DPSS-61XX) and panels that integrate its moisture, oxygen and CO₂ analyzers.
Systems are configured to the project: tell us the process gas, pressure, temperature, sample point and the measurements you need, and we will propose a configuration.
What an analyzer panel includes
An analyzer panel brings the sample from the process to the analyzer in the right condition, so the reading represents the process. A typical YORK panel for moisture or oxygen includes:
- Sample probe and isolation valve at the process connection.
- Pressure reduction. YORK dew point sensors and chilled mirrors are rated to 4 barg, so high-pressure gas is reduced and measured near atmospheric pressure; the instrument then converts the reading to dew point at line pressure.
- Filtration for particles and, in natural gas, coalescing filters against glycol and hydrocarbon liquids.
- Flow control and a fast bypass loop, so the sample is fresh and the response time stays short.
- Heat tracing of lines and regulators where the gas could cool below its dew point.
- Analyzers, outputs and alarms wired to a terminal box for the plant control system.
Panel, cabinet or analyzer shelter?
| Format | Typical use |
|---|---|
| Open analyzer panel | Indoor or sheltered locations, one or two measurement points, easy access for maintenance |
| Analyzer cabinet | Outdoor installation; protects the analyzers from sun, dust and rain |
| Analyzer shelter | Several analyzers and sample systems in one walk-in enclosure, with climate control for the instruments and space for maintenance |
YORK builds analyzer panels, cabinets and analyzer shelters at its factory in Chengdu, China, around its own moisture, oxygen and CO₂ analyzers and to the project specification.
Design points for Gulf sites
- Summer ambient above 50 °C and direct sun: specify sun shades, cabinet cooling or a climate-controlled shelter, and check the analyzers’ operating temperature range.
- Sample lines that pass through cooler air-conditioned spaces or run at night can drop below the gas dew point: heat-trace them.
- Dust and sand: use sealed enclosures and plan filter changes.
- Hazardous areas: use certified analyzers such as the DPT990-EX and PGA500-EX; the PGA520 and PGA620 CO₂ analyzers have no explosion-proof version and go in a safe area. Certificate details are sent with quotations.
What to send for a quotation
- Process gas and composition, including CO₂, H₂S and heavy hydrocarbons
- Line pressure and temperature at each sample point
- Measurements and ranges: dew point, trace or percent O₂, CO₂
- Area classification, installation (indoor, outdoor, shelter) and ambient conditions
- Outputs and communication to the control system, and the project specifications that apply
Applications
Questions
Which YORK sampling and analyzer systems are available?
The range includes DPSS-61XX, Analyzer panels. See the comparison table on this page for types and measuring ranges.
Who supplies YORK instruments in the GCC?
YORK Instrument has a Dubai-based regional contact covering the UAE, Saudi Arabia, Qatar, Oman, Kuwait and Bahrain: dubai@yorkinstrument.com, +971 55 137 4866.
Does YORK build analyzer shelters?
Yes. YORK builds analyzer panels, cabinets and analyzer shelters at its factory in Chengdu, China, integrating its moisture, oxygen and CO₂ analyzers and sample systems to the project specification.
What sample pressure do YORK moisture analyzers accept?
YORK dew point sensors and chilled mirror hygrometers are rated to 4 barg. On higher-pressure lines the sample system reduces the pressure, and the instrument converts the reading to dew point at line pressure.
Need help choosing?
Tell us the gas, pressure, measuring range and quantity, and our Dubai contact will propose a model.