YORK DC2000 low humidity generator
The DC2000 is a low humidity generator for calibrating dew point instruments. It mixes dry and wet gas with four electronic mass flow controllers to produce stable low dew point set points, with stability better than ±0.2 °C frost point, and feeds a reference hygrometer and two instruments under test.

| Model | DC2000 |
|---|---|
| Type | Low humidity generator |
| Principle | Flow-divided wet/dry gas mixing |
| Flow control | Four electronic mass flow controllers |
| Stability | Better than ±0.2 °C frost point |
| Set points | Multiple user-configurable calibration points |
| Outlets | Three: one reference, two for calibration |
| Connections | 1/4" stainless steel compression fittings |
| Dry gas source | For example the DC1000 |
| Lead time | 6 to 8 weeks |
| Warranty | 12 months from shipment |
| Regional contact | Dubai, UAE — covers the GCC |
Product catalog (PDF) · certificate copies are sent with quotations.
How a calibration run works
- Feed dry gas from the DC1000 to the DC2000.
- Connect the reference hygrometer to the reference outlet and the instruments under test to the two calibration outlets.
- Program the calibration points, working from dry to wet.
- At each point, wait until the generator, reference and instruments are stable, then record.
- Issue the results; see how to calibrate a dew point sensor for the full procedure.
Where it is used
| User | Purpose |
|---|---|
| Calibration laboratories | Multi-point dew point calibration; see calibration laboratories |
| Instrument service companies | In-house checks of transmitters and portable meters |
| Industrial plants with many dew point points | Recalibration of their own transmitters |
DC2000 or a complete system?
| If you need… | Choose |
|---|---|
| The generator only, with your own dry gas and reference | DC2000 |
| Dry gas source | DC1000 |
| A complete rack bench with compressor, generators and reference | YKDC220 |
Ordering in the UAE and GCC
Send your enquiry to our Dubai team with:
- the dew point range and calibration points;
- your dry gas source and reference hygrometer;
- quantity.
We reply with a quotation for the DC2000. Instruments are shipped from the factory with export documents, 6 to 8 weeks from order confirmation. Tell us your reference hygrometer and the points you need.
Questions about the DC2000
How stable is the DC2000?
Better than ±0.2 °C frost point.
How many instruments can be calibrated at once?
The DC2000 has three outlets: one for the reference hygrometer and two for instruments under test.
Does the DC2000 need a dry gas source?
Yes, for example the DC1000 dry gas generator.
How do I get a quotation in the UAE?
Email dubai@yorkinstrument.com or WhatsApp +971 55 137 4866 with the dew point range, calibration points and quantity.