CAL · Calibration

YORK DC2000 low humidity generator

The DC2000 is a low humidity generator for calibrating dew point instruments. It mixes dry and wet gas with four electronic mass flow controllers to produce stable low dew point set points, with stability better than ±0.2 °C frost point, and feeds a reference hygrometer and two instruments under test.

YORK DC2000 – Low humidity generator
ModelDC2000
TypeLow humidity generator
PrincipleFlow-divided wet/dry gas mixing
Flow controlFour electronic mass flow controllers
StabilityBetter than ±0.2 °C frost point
Set pointsMultiple user-configurable calibration points
OutletsThree: one reference, two for calibration
Connections1/4" stainless steel compression fittings
Dry gas sourceFor example the DC1000
Lead time6 to 8 weeks
Warranty12 months from shipment
Regional contactDubai, UAE — covers the GCC

Product catalog (PDF) · certificate copies are sent with quotations.

How a calibration run works

  1. Feed dry gas from the DC1000 to the DC2000.
  2. Connect the reference hygrometer to the reference outlet and the instruments under test to the two calibration outlets.
  3. Program the calibration points, working from dry to wet.
  4. At each point, wait until the generator, reference and instruments are stable, then record.
  5. Issue the results; see how to calibrate a dew point sensor for the full procedure.

Where it is used

UserPurpose
Calibration laboratoriesMulti-point dew point calibration; see calibration laboratories
Instrument service companiesIn-house checks of transmitters and portable meters
Industrial plants with many dew point pointsRecalibration of their own transmitters

DC2000 or a complete system?

If you need…Choose
The generator only, with your own dry gas and referenceDC2000
Dry gas sourceDC1000
A complete rack bench with compressor, generators and referenceYKDC220

Ordering in the UAE and GCC

Send your enquiry to our Dubai team with:

  • the dew point range and calibration points;
  • your dry gas source and reference hygrometer;
  • quantity.

We reply with a quotation for the DC2000. Instruments are shipped from the factory with export documents, 6 to 8 weeks from order confirmation. Tell us your reference hygrometer and the points you need.

Questions about the DC2000

How stable is the DC2000?

Better than ±0.2 °C frost point.

How many instruments can be calibrated at once?

The DC2000 has three outlets: one for the reference hygrometer and two for instruments under test.

Does the DC2000 need a dry gas source?

Yes, for example the DC1000 dry gas generator.

How do I get a quotation in the UAE?

Email dubai@yorkinstrument.com or WhatsApp +971 55 137 4866 with the dew point range, calibration points and quantity.