The YKDC220 is a complete low humidity calibration system for calibrating dew point analyzers and transmitters in-house. It combines an oil-free compressor system, the DC1000 dry gas generator, the DC2000 low humidity generator and a chilled mirror reference hygrometer (DM9700, DM9800 or DM9900) in a 19-inch rack.

YORK YKDC220 – Dew point calibration system
ModelYKDC220
TypeDew point calibration system
Format19-inch rack; compressor installed separately
CompressorOil-free compressor system (YK-2×750-55)
Dry gas generatorDC1000
Low humidity generatorDC2000
Reference hygrometerDM9700, DM9800 or DM9900
ConfigurationConfigured and quoted per project
Lead time6 to 8 weeks
Regional contactDubai, UAE — covers the GCC

Product catalog (PDF) · certificate copies are sent with quotations.

Choosing the reference

ReferenceLowest frost pointChoose when
DM9700−70 °CYour instruments work above −70 °C
DM9800−80 °CYou calibrate trace moisture transmitters
DM9900−90 °CYou need the lowest range and reference accuracy, better than ±0.2 °C near −90 °C

Who uses it

UserPurpose
Calibration laboratoriesAdding low dew point to their scope; see calibration laboratories
Industrial plants and service companiesRecalibrating their own dew point transmitters every year instead of sending them abroad
Metrology institutesLow dew point capability

What you need on site

  • A room for the 19-inch rack and a separate location for the compressor.
  • Power for the rack and compressor.
  • For accredited calibration, a laboratory quality system to ISO/IEC 17025; accreditation is by EIAC in the UAE and SAAC in Saudi Arabia. See how to calibrate a dew point sensor.

Ordering in the UAE and GCC

Send your enquiry to our Dubai team with:

  • the instruments and dew point range you calibrate;
  • the reference hygrometer you prefer;
  • your site and power;
  • whether you plan ISO/IEC 17025 accreditation.

We reply with a quotation for the YKDC220. Instruments are shipped from the factory with export documents, 6 to 8 weeks from order confirmation. A calibration certificate for the DM9900 reference is available at extra cost.

Questions about the YKDC220

What does the YKDC220 include?

An oil-free compressor system, the DC1000 dry gas generator, the DC2000 low humidity generator and a DM9700, DM9800 or DM9900 chilled mirror reference, in a 19-inch rack.

Which reference should I choose?

DM9700 to −70 °C, DM9800 to −80 °C, or DM9900 to −90 °C frost point, depending on the lowest point you calibrate.

Can the YKDC220 be used for accredited calibration?

It provides the equipment; accreditation also needs a quality system to ISO/IEC 17025 and assessment by EIAC or SAAC.

How do I get a quotation in the UAE?

Email dubai@yorkinstrument.com or WhatsApp +971 55 137 4866 with the instruments, dew point range and preferred reference.