CAL · Calibration
YORK DC1000 dry gas generator
The DC1000 is a pressure swing adsorption dry gas generator that supplies up to 10 NL/min of dry air below 1 ppmV, equivalent to −75 °C dew point. It is the dry gas source for dew point calibration benches, feeding a low humidity generator and providing a dry reference for checking dew point instruments.

| Model | DC1000 |
|---|---|
| Type | Dry gas generator |
| Principle | Pressure swing adsorption |
| Output | Up to 10 NL/min of dry air below 1 ppmV (−75 °C dew point) |
| Connections | 1/4" stainless steel compression fittings |
| Lead time | 6 to 8 weeks |
| Warranty | 12 months from shipment |
| Regional contact | Dubai, UAE — covers the GCC |
Product catalog (PDF) · certificate copies are sent with quotations.
Where it is used
| Use | Role of the DC1000 |
|---|---|
| Dew point calibration bench | Dry gas feed to the DC2000 low humidity generator |
| Checking dew point instruments | A dry reference gas for verifying the low end of a sensor's response |
| Complete calibration system | Built into the YKDC220 |
Good practice
- Feed the DC1000 from an oil-free compressed air supply.
- Use stainless steel lines from the generator to the instruments, as short as possible.
- Allow time for lines to dry down before low-point calibrations.
- The procedure for a calibration bench is described in how to calibrate a dew point sensor.
Building a calibration bench
| Item | YORK option |
|---|---|
| Dry gas source | DC1000 |
| Low humidity generator | DC2000 |
| Reference hygrometer | DM9900, DM9800 or DM9700 |
| Complete rack system | YKDC220 |
Ordering in the UAE and GCC
Send your enquiry to our Dubai team with:
- the instruments and dew point range you calibrate;
- the number of instruments per run;
- your compressed air supply;
- quantity.
We reply with a quotation for the DC1000. Instruments are shipped from the factory with export documents, 6 to 8 weeks from order confirmation. Tell us the instruments you want to calibrate so we can propose the full bench.
Questions about the DC1000
How dry is the DC1000 output?
Below 1 ppmV, equivalent to −75 °C dew point, at up to 10 NL/min.
What is the DC1000 used with?
The DC2000 low humidity generator and a chilled mirror reference, or as part of the YKDC220 system.
What connections does it have?
1/4" stainless steel compression fittings.
How do I get a quotation in the UAE?
Email dubai@yorkinstrument.com or WhatsApp +971 55 137 4866 with the instruments you calibrate, the dew point range and quantity.

