العربية
  1. Home
  2. Products
  3. Explosion-proof analyzers
  4. DPT990-EX

Ex · Hazardous area

YORK DPT990-EX explosion-proof dew point analyzer

The DPT990-EX is an explosion-proof, in-line dew point analyzer for gas plants and other classified areas, from −110 °C frost point to +20 °C dew point. It is used at glycol and molecular sieve dehydration outlets, on sales and fuel gas, and on other process gas lines where the analyzer must sit in the hazardous area.

YORK DPT990-EX – Explosion-proof dew point analyzer
ModelDPT990-EX
TypeExplosion-proof dew point analyzer
Range−110 °C frost point to +20 °C dew point
SensorNano-porous metal-oxide film
Explosion protectionEx d IIC T4 Gb; certificate details are sent with quotations
HousingExplosion-proof aluminium alloy
OutputsAnalog output, digital output, alarm relay
PowerAC or DC supply
Sample pressureUp to 4 barg; measure at reduced pressure and convert to line-pressure dew point
GasesGas phase only; fit a filter if the gas carries glycol or methanol
Lead time6 to 8 weeks
Warranty12 months from shipment
Regional contactDubai, UAE — covers the GCC

Product catalog (PDF) · certificate copies are sent with quotations.

Where it is installed

LocationWhat is measured
Glycol dehydration outletWater dew point to confirm the contactor and regeneration are working; see natural gas water dew point
Molecular sieve dryer outletTrace moisture before LNG liquefaction or NGL recovery; see molecular sieve breakthrough
Sales gas and export pointsWater dew point against the gas sales agreement
Fuel gas to turbines and fired heatersWater dew point of the fuel gas
Process gases in refineries and petrochemical plantsMoisture at dryer outlets; see process gas

Sample system

  • Reduce the sample pressure to 4 barg or less at the tapping point and measure close to atmospheric pressure; report the line-pressure dew point with the conversion.
  • Heat the pressure reducer and, where needed, the sample line, so that water or hydrocarbons do not condense as the gas expands.
  • Fit a coalescing filter where glycol, methanol or liquids may be carried over.
  • YORK builds the sample conditioning system, panel or analyzer shelter around the analyzer at its factory in Chengdu.

DPT990-EX or another YORK instrument?

If you need…Choose
Continuous monitoring in a hazardous areaDPT990-EX
Continuous monitoring in a safe area or shelterDPT830
Portable checks in a hazardous areaDPT-600 Plus-EX (see DPT-600 Plus)
Trace oxygen in a hazardous areaPGA500-EX

Ordering in the UAE and GCC

Send your enquiry to our Dubai team with:

  • the gas and where it is measured;
  • the expected dew point and line pressure;
  • whether the measurement point is in a hazardous area;
  • quantity.

We reply with a quotation for the DPT990-EX, with or without a sample system. Instruments are shipped from the factory with export documents, 6 to 8 weeks from order confirmation. Certificate details are sent with quotations. Where a project specifies IECEx or ATEX, ask us first; the analyzer can also be installed in a safe area with the sample line brought to it.

See all dew point meters and analyzers available in the UAE.

Questions about the DPT990-EX

What is the Ex marking of the DPT990-EX?

Ex d IIC T4 Gb. Certificate details are sent with quotations.

Can the DPT990-EX measure water dew point in natural gas at pipeline pressure?

Measure at reduced pressure, up to 4 barg, and use the conversion to report the dew point at line pressure. Heat the pressure reducer to avoid condensation.

What if the gas contains glycol or methanol?

Fit a filter upstream of the sensor. Where carry-over is persistent, a laser (TDLAS) analyzer supplied as an integrated system is an alternative; see chilled mirror vs TDLAS vs metal-oxide.

Does YORK supply the sample system and shelter?

Yes. The sample conditioning system, panel or analyzer shelter is built at YORK's factory in Chengdu to the project specification.

How do I get a quotation in the UAE?

Email dubai@yorkinstrument.com or WhatsApp +971 55 137 4866 with the gas, line pressure, dew point, area classification and quantity.