Sulfur recovery, fuel gas and flare: where to measure
Most analyzers in a sulfur recovery unit are specialised sulfur and combustion analyzers that YORK supplies as integrated systems. YORK instruments cover the flare header oxygen, the purge nitrogen and the instrument air.
Tap a numbered point. Swipe the diagram sideways on a phone.
⤓ Download the 2-page PDF application note
How the process works
The sulfur recovery unit turns H₂S from the amine regenerator and sour water stripper into liquid sulfur, and the tail gas unit cleans up what is left. Here the key analyses are sulfur ratios and combustion control, which need specialised analyzers. YORK supplies them as integrated systems, alongside its own instruments for oxygen and dew point.
- Claus furnace. Part of the H₂S burns with air to SO₂; the air rate is trimmed from the tail gas H₂S:SO₂ ratio.
- Waste heat boiler and converters. The gas is cooled and passes catalytic converters, where H₂S and SO₂ react to sulfur that condenses as a liquid.
- Tail gas unit. A reducing-gas burner and hydrogenation reactor turn the remaining sulfur compounds into H₂S, which a quench column and amine absorber remove.
- Incinerator. Residual H₂S is burned before the gas leaves the stack.
- Fuel gas and flare. The fuel gas header feeds the heaters; the flare header collects relief and blowdown gas and is kept free of air by purge gas.
Measurement points at a glance
| # | Point | Measures | Typical value / limit | Recommended solution |
|---|---|---|---|---|
| 1 | Claus tail gas | H₂S to SO₂ ratio | 2:1 is the stoichiometric reference; operators often target 2:1 to 4:1 | Integrated system: UV air-demand analyzer |
| 2 | Tail gas unit, after hydrogenation | Excess hydrogen | About 2.1 % at 10 % excess air (simulated example) | Integrated system: thermal-conductivity H₂ analyzer |
| 3 | Tail gas unit, reducing-gas burner | Oxygen ingress | Firing above about 90 % of stoichiometric air risks oxygen reaching the hydrogenation catalyst | Integrated system: zirconia O₂ analyzer |
| 4 | Incinerator stack | Excess oxygen | Plant-specific: set to keep destruction efficiency and permit compliance | POA3500; Integrated system: in-situ zirconia O₂ analyzer |
| 5 | Refinery fuel gas header | H₂S | Set by the emission permit for the heaters (limit not reproduced here) | Integrated system: H₂S analyzer |
| 6 | Flare header | Oxygen (air ingress) | No single published limit; an O₂ signal can trigger purge or make-up gas injection | Integrated system: O₂ analyzer qualified for wet sour gas in Zone 1/2 |
| 7 | Flare vent gas | Heating value and composition | Set by local flare regulations (limit not reproduced here) | Integrated system: process GC or calorimeter |
| 8 | Purge and blanket nitrogen | Oxygen (%) | Keep oxygen below the limiting oxygen concentration with margin (NFPA 69), e.g. about ≤ 10 % for methane | PGA500-EX |
| 9 | Instrument air header | Pressure dew point | At least 10 °C below the lowest ambient temperature, and never above 4 °C at line pressure (ISA-7.0.01) | DPT810, DM9200, DPT-600 Plus-EX |
Values are typical figures from published specifications and technical literature. Your contract, licensor or plant specification always governs.
Getting reliable readings
- Heat the sulfur lines. Sulfur vapour condenses in cold sample lines and plugs them.
- Wet and dry basis. In-situ zirconia reads oxygen on a wet basis; an extractive analyzer after a cooler reads dry. Compare like with like.
- Hazardous areas. Flare and fuel gas points are in classified areas: use explosion-proof analyzers or a certified analyzer shelter.
- Purge before work. Confirm the oxygen level with a portable analyzer before opening equipment or starting hot work.
References
- Hatcher et al., SO₂ breakthrough under the microscopeDigital Refining
- Q&A Q27 (2017): sulfur block best practicesAFPM
- Dynamic simulation modeling to protect flare headers from air ingress (AIChE 2016)AIChE
- Inerting, purging, discharge location and containment (NFPA 69 summary)Open Exam Prep
- Understanding ISA-7.0.01-1996 Instrument Air StandardCompressed Air Best Practices
Frequently asked questions
Why is the H₂S:SO₂ ratio measured in the Claus tail gas?
The ratio controls the combustion air to the Claus furnace. About 2:1 gives the best conversion; excess air sends SO₂ to the tail gas unit.
Why monitor oxygen in a flare header?
Air drawn into the header or stack can create an explosive mixture. An oxygen analyzer warns the operator and can trigger purge or make-up gas.
Which sulfur recovery points does YORK cover?
YORK instruments cover flare header oxygen, purge nitrogen and instrument air dew point. Sulfur ratio, hydrogen, zirconia oxygen and GC points are supplied by YORK as integrated systems.
Planning analyzers for a sulfur or flare system?
Send us the points, area classification and utilities, and we will propose the analyzers and sampling systems.