YORK DM9200 chilled mirror hygrometer with insertion probe
The DM9200 is a chilled mirror hygrometer for high dew points, from −30 °C frost point to +90 °C dew point, with dew point accuracy of ±0.1 °C. Its remote measuring head and PRT temperature probe, each on a 3 m cable, can be placed inside climatic and environmental test chambers, so it is used to verify chamber humidity and as a reference for calibrating relative humidity and dew point sensors.

| Model | DM9200 |
|---|---|
| Type | Chilled mirror hygrometer with remote measuring head |
| Range | −30 °C frost point to +90 °C dew point |
| Accuracy | ±0.1 °C dew point |
| Principle | Chilled mirror |
| Measuring head | Remote, on a 3 m cable |
| Temperature | PRT probe on a 3 m cable |
| Use | Non-flammable gases in safe areas; sample pressure up to 4 barg |
| Lead time | 6 to 8 weeks |
| Warranty | 12 months from shipment |
| Regional contact | Dubai, UAE — covers the GCC |
Product catalog (PDF) · certificate copies are sent with quotations.
Where it is used
| User | What it measures |
|---|---|
| Climatic and environmental test chambers | Dew point and humidity inside the chamber during qualification; see climatic chamber measurement points |
| Humidity calibration laboratories | Reference for relative humidity and dew point sensors at high dew points; see calibration laboratories |
| Meteorology | Reference checks of humidity sensors; see meteorology measurement points |
| Process humidity in safe areas | Dew point of humid air in dryers and conditioning rooms |
Good practice
- Keep the measuring head and its cable above the dew point of the gas, so water does not condense on them.
- With the PRT probe in the same space, the instrument gives both dew point and temperature, from which relative humidity follows.
- Keep the mirror clean; contamination shifts the reading.
- YORK chilled mirror hygrometers are low-pressure instruments for non-flammable gases in safe areas; they are not explosion-proof and are not intended for natural gas, hydrogen or other flammable gases.
DM9200 or another YORK chilled mirror?
| If you need… | Choose |
|---|---|
| Benchtop instrument to −60 °C frost point | DM9600 |
| Portable checks to −60 °C frost point | DM9600P |
| Portable checks to −70 °C frost point | DM9600PL |
| Rack-mount monitoring to −70 or −80 °C frost point | DM9700 or DM9800 |
| Laboratory reference to −90 °C frost point | DM9900 |
| Flammable gases or hazardous areas | A metal-oxide instrument: DPT-600 Plus-EX or DPT990-EX |
Ordering in the UAE and GCC
Send your enquiry to our Dubai team with:
- the application (chamber, calibration, process);
- the dew point and temperature range;
- quantity.
We reply with a quotation for the DM9200. Instruments are shipped from the factory with export documents, 6 to 8 weeks from order confirmation. Tell us the chamber or application so we can confirm the configuration.
See all dew point meters and analyzers available in the UAE.
Questions about the DM9200
What is the range of the DM9200?
−30 °C frost point to +90 °C dew point.
What is the accuracy of the DM9200?
±0.1 °C dew point.
Can the DM9200 measure inside a climatic chamber?
Yes. The remote measuring head and PRT probe are on 3 m cables and can be placed inside the chamber.
Can it be used for natural gas or other flammable gases?
No. YORK chilled mirror hygrometers are low-pressure instruments (up to 4 barg) and are not explosion-proof; they are for non-flammable gases in safe areas. For natural gas, see the DPT990-EX.
How do I get a quotation in the UAE?
Email dubai@yorkinstrument.com or WhatsApp +971 55 137 4866 with the application, dew point range and quantity.