Refining and petrochemicals: where to measure moisture, O₂ and CO₂

Twelve points across hydrogen, reforming, isomerization, olefins, polymers, ethylene oxide and utilities. Each shows the typical limit, why it matters and the analyzer that fits.

C₅/C₆AIR + N₂N₂C₂H₄ + O₂H₂ PLANT(PSA)HYDROTREATERREFORMERSEPARATORFEED DRIERISOMREACTORSTEAM CRACKERDRIERCOLD SECTIONC₂H₄ / C₃H₆POLYMER GRADEPE / PP REACTOREO REACTORN₂-BLANKETED TANKCATALYST REGENINSTRUMENT AIRDRYER1CO2H₂O·HCl3H₂O4H₂O5H₂O6O₂7GC8O₂9CO₂10O₂11O₂12H₂O
YORK instrumentIntegrated system (supplied through YORK)

Tap a numbered point. Swipe the diagram sideways on a phone.

Request a quote for this point →
Auto tour
Project list 0 →

How the process works

A refinery or petrochemical complex is a set of units, not one line. The map groups the units where gas analysis protects a catalyst, a product specification or plant safety.

  1. Hydrogen and hydrotreating. A PSA unit supplies make-up hydrogen. Trace CO and CO₂ in it inhibit hydrotreating catalysts.
  2. Catalytic reforming. The recycle hydrogen loop needs a tight water–chloride balance. Its HCl content rules out conventional metal-oxide moisture sensors.
  3. Isomerization. Feed driers protect a catalyst that water destroys permanently, so the drier outlet is alarmed.
  4. Steam cracking and olefins. Cracked gas is dried before the cold section. Polymer-grade ethylene and propylene are checked for water, oxygen, CO, CO₂ and acetylene before the PE/PP reactors.
  5. Ethylene oxide. The reactor cycle gas runs close to its flammable limit, so oxygen is part of the safety system and CO₂ is controlled for selectivity.
  6. Utilities and safety. Nitrogen blanketing keeps tanks below the limiting oxygen concentration, catalyst regeneration burns coke under controlled oxygen, and instrument air stays dry.

Measurement points at a glance

#PointMeasuresTypical value / limitRecommended solution
1Make-up hydrogen from the PSA unitCO + CO₂ (ppm)Typically < 10 ppmv; 10–50 ppmv slip is common; catalyst limits range from < 20 to 100 ppmIntegrated system: process GC with methanizer-FID
2Catalytic reformer recycle hydrogenWater and HClWater: semi-regen target 20 ± 5 ppmv; CCR 15–20 ppmv, max 30 ppmv. HCl: < 3 vol ppmIntegrated system: laser (TDLAS) moisture and HCl analyzer
3Isomerization feed drier outletTrace waterSub-ppm water: chlorided-alumina catalyst is irreversibly deactivated by waterDPT830, DPT990-EX
4Cracked-gas molecular-sieve drier outletTrace waterBelow 1 ppmvIntegrated system: laser (TDLAS) moisture analyzer
5Polymer-grade ethylene / propyleneWaterEthylene ≤ 7.8 ppm mol (5 ppmw), or ≤ 10 ppm v/v in another specification; propylene ≤ 5 ppmDPT830, DPT990-EX
6Polymer-grade ethylene / propyleneOxygenEthylene ≤ 0.5 ppm mol; propylene ≤ 2–5 ppmPGA500, PGA500-EX, POA200
7PE / PP reactor feedCO, CO₂, acetyleneEthylene: CO ≤ 1, CO₂ ≤ 3, C₂H₂ ≤ 3 ppm mol; propylene: CO ≤ 0.07–0.3 ppmIntegrated system: process GC with methanizer-FID
8Ethylene oxide reactor cycle gasOxygen (%)5–10 mol % (8 % in a patent example); the shutdown trip is set from the flammability limitPOA3500; Integrated system: redundant paramagnetic oxygen analyzers (SIL-rated)
9Ethylene oxide reactor cycle gasCO₂ (%)1–15 mol % (another design 0.5–10 %)Integrated system: NDIR CO₂ analyzer, explosion-proof or in a purged shelter
10Tank and reactor nitrogen blanketingOxygen (%)NFPA 69 margin, for example ≤ about 10 % O₂ for methane service and ≤ about 3 % for hydrogenPGA500-EX
11Catalyst regeneration gasOxygen (%)0.1–2.0 vol %; CCR burn zone usually 0.5–1.5 vol %POA3500; Integrated system: paramagnetic or zirconia oxygen analyzer for acid-gas service
12Instrument air headerPressure dew pointAt least 10 °C below the lowest ambient temperature, and never above 4 °C at line pressure (ISA-7.0.01)DPT810, DM9200, DPT-600 Plus-EX

Values are typical figures from published specifications and technical literature. Your contract, licensor or plant specification always governs.

Getting reliable readings

  • Check the matrix first. HCl, heavy hydrocarbons and acid gases decide which sensor survives. Where a stream is chloride- or acid-bearing, YORK supplies an integrated analyzer suited to it.
  • Vaporise liquids completely. Propylene and other liquefied streams must be vaporised without fractionation before a gas-phase measurement.
  • Trace levels need tight sample systems. Sub-ppm water and oxygen need leak-tight, electropolished stainless tubing and steady flow.
  • Hazardous area. Most process points are in Zone 1 or Zone 2: use explosion-proof analyzers or a certified analyzer shelter.

Frequently asked questions

Which moisture analyzer suits reformer recycle hydrogen?

The recycle gas carries HCl, which is corrosive to conventional metal-oxide moisture sensors. A laser (TDLAS) moisture analyzer is used, which YORK supplies as an integrated system.

What are typical limits for polymer-grade ethylene?

Published specifications set water at about 7.8 ppm mol, oxygen at 0.5 ppm mol, CO at 1 ppm mol, CO₂ at 3 ppm mol and acetylene at 3 ppm mol.

How much oxygen is allowed in a nitrogen-blanketed tank?

NFPA 69 keeps oxygen a margin below the limiting oxygen concentration, for example about 10 % for methane service and about 3 % for hydrogen.

What instrument air dew point is required?

ISA-7.0.01 asks for a pressure dew point at least 10 °C below the lowest ambient temperature, and never above 4 °C at line pressure.

Planning analyzers for a refinery or petrochemical plant?

Send us the units, streams and area classification, and we will propose the instruments and sampling systems.