العربية
  1. Home
  2. Products
  3. Dew point analyzers and transmitters
  4. DPT810

H₂O · Dew point

YORK DPT810 dew point transmitter

The DPT810 is a fixed dew point transmitter with a nano-porous metal-oxide sensor, covering −110 °C to +20 °C dew point. It is the compact choice for continuous dew point at dryer outlets and on nitrogen and dry air lines in safe areas, where the measurement goes straight to a PLC or building management system.

YORK DPT810 – Dew point transmitter
ModelDPT810
TypeDew point transmitter
Range−110 °C to +20 °C dew point
SensorNano-porous metal-oxide film
Sample pressureUp to 4 barg; measure at reduced pressure and convert to line-pressure dew point
GasesGas phase only
Hazardous areasUse the DPT990-EX
Lead time6 to 8 weeks
Warranty12 months from shipment
Regional contactDubai, UAE — covers the GCC

Product catalog (PDF) · certificate copies are sent with quotations.

Where it is installed

LocationWhy
Compressed air dryer outletsContinuous pressure dew point against the ISO 8573-1 class; see the ISO 8573-1 air class tool
Nitrogen and dry air linesConfirm the gas reaching the point of use is dry
Plastic resin dryersDew point of the drying air; see resin drying

Installation notes

  • Mount the sensor in a sampling cell with a small continuous flow, or directly in the line where the pressure is 4 barg or less.
  • Use stainless steel fittings and lines; plastic tubing lets moisture in.
  • Allow dry-down time after installation before relying on low readings.
  • Recalibrate typically every 12 months; see how to calibrate a dew point sensor.

DPT810 or another YORK instrument?

If you need…Choose
A compact fixed transmitterDPT810
An analyzer with analog, digital and alarm relay outputsDPT830
Continuous measurement in a hazardous areaDPT990-EX
Portable spot checksDPT-600 Plus

Ordering in the UAE and GCC

Send your enquiry to our Dubai team with:

  • the gas and where it is measured;
  • the expected dew point and line pressure;
  • whether the measurement point is in a hazardous area;
  • quantity.

We reply with a quotation for the DPT810. Instruments are shipped from the factory with export documents, 6 to 8 weeks from order confirmation. Output and connection options are confirmed with the quotation.

See all dew point meters and analyzers available in the UAE.

Questions about the DPT810

What is the range of the DPT810?

−110 °C to +20 °C dew point.

What is the difference between the DPT810 and the DPT830?

The DPT830 is an analyzer with analog, digital and alarm relay outputs; the DPT810 is a compact transmitter for direct connection to a control system.

Can the DPT810 be used in a hazardous area?

No. Use the DPT990-EX explosion-proof dew point analyzer.

How do I get a quotation in the UAE?

Email dubai@yorkinstrument.com or WhatsApp +971 55 137 4866 with the gas, dew point, pressure and quantity.