Natural gas processing: where to measure moisture, O₂ and CO₂

Follow the gas from the inlet separator to the custody meter. Each numbered point shows what is measured, the typical limit, why it matters and the analyzer that fits.

FEEDTO PIPELINETO GAS TURBINENGLROUTE A · TEG TO PIPELINE SPECROUTE B · MOL SIEVE + NGL RECOVERYINLET SEPARATORAMINECONTACTORTEGMOL SIEVENGL COLD BOXCOMPRESSORCUSTODYMETERINGFUEL GAS SKID1O₂2CO₂3H₂S4H₂O5H₂O6Hg7H₂O8HCDP9O₂10GC11H₂O
YORK instrumentIntegrated system (supplied through YORK)

Tap a numbered point. Swipe the diagram sideways on a phone.

Request a quote for this point →
Auto tour
Project list 0 →

How the process works

Raw gas from the wells arrives water-saturated and carries CO₂, H₂S and sometimes oxygen. The plant removes each of them in turn, and an analyzer after each step proves the step worked.

  1. Inlet separation. Slug catchers and separators remove free liquids. Inlet water is calculated, not measured, because the gas is saturated.
  2. Acid gas removal. An amine contactor absorbs CO₂ and H₂S down to the pipeline limit, or to ppm levels when the gas goes on to LNG.
  3. Dehydration. For pipeline gas, triethylene glycol (TEG) absorbs water in a contactor. Where the gas goes to cryogenic NGL recovery, molecular-sieve beds dry it far deeper, to below 0.1 ppmv.
  4. NGL recovery. A turbo-expander cold box condenses ethane and heavier liquids. Mercury guard beds protect its aluminium exchangers.
  5. Compression and custody transfer. Residue gas is compressed and metered against the sales contract: water dew point, hydrocarbon dew point, O₂, CO₂, H₂S and heating value.
  6. Fuel gas. A side stream feeds gas turbines, which need the gas superheated above its dew points.

Measurement points at a glance

#PointMeasuresTypical value / limitRecommended solution
1Plant inlet / gathering headerOxygen (ppm)Case study: 90–100 ppmv at the inlet damaged the amine; the pipeline limit was < 2,000 ppmvDPSS-61XX; Integrated system: trace O₂ analyzer qualified for wet sour gas
2Amine contactor outletCO₂ (%)Pipeline: ≤ 2.0 vol% (US tariff example), ≤ 2.0 mol% (UK network entry)Integrated system: explosion-proof NDIR CO₂ analyzer with a 0–5 vol % range
3Amine contactor outletH₂S and total sulfurUS tariff example: 0.5 grain/100 scf (≈ 8 ppmv); UK network entry: ≤ 5 mg/m³Integrated system: H₂S analyzer (lead-acetate tape or UV)
4TEG contactor outletWater content / water dew point at line pressureTypically 7 lb/MMscf (≈ 147 ppmv) in US pipelines; −8 °C at 70 bar under EN 16726DPT830, DPT990-EX, DPSS-61XX, DPT-600 Plus-EX
5Molecular-sieve dryer outletTrace water (ppmv)< 0.1 ppmv (≈ −90 °C frost point at 1 atm)DPT830, DPT990-EX
6Mercury guard bed outletMercuryDown to 0.01 µg/Nm³ reportedIntegrated system: mercury analyzer (cold-vapour atomic absorption or fluorescence)
7Custody transfer / pipeline entryWater dew point at stated pressureUS: ≤ 7 lb/MMscf (some ≤ 4); EU: −8 °C at 70 bar; UK: −10 °C at 85 barg. GCC: per the gas sales agreementDPT830, DPT990-EX
8Custody transfer / pipeline entryHydrocarbon dew pointUK entry: ≤ −2 °C at any pressure up to 85 bar; other networks −10 °C at 54–60 barIntegrated system: automatic hydrocarbon dew point analyzer, or calculation from process GC (ISO 23874)
9Custody transfer / pipeline entryOxygenUS tariff example ≤ 0.2 vol%; EN 16726: 10 ppm for sensitive users; UK entry ≤ 0.2 % above 38 bargPGA500-EX, PGA500
10Custody transfer / pipeline entryComposition, heating value, Wobbe index, total sulfurCalculated from the mole-fraction composition per ISO 6976Integrated system: process gas chromatograph (C6+/C9+) with sulfur detection
11Gas turbine fuel gas skidWater dew pointFuel must be supplied at least 11 °C (20 °F) above its highest dew point (one turbine OEM specification)DPT810, DPT990-EX

Values are typical figures from published specifications and technical literature. Your contract, licensor or plant specification always governs.

Getting reliable readings

  • State the pressure. A water dew point means nothing without its pressure basis. Specifications quote it at line pressure, for example −8 °C at 70 bar.
  • Glycol and methanol. Vapour from the TEG unit or from hydrate-inhibitor injection biases metal-oxide sensors. Use a coalescing filter and sample upstream of methanol injection.
  • Heavy hydrocarbons. In rich gas, hydrocarbons can condense on a chilled mirror before water does. The reading can then be the hydrocarbon dew point, not the water dew point. Measure water dew point with a metal-oxide or TDLAS analyzer, and hydrocarbon dew point with a separate analyzer.
  • Hazardous area. Most of these points are in Zone 1 or Zone 2, so use explosion-proof analyzers or a certified analyzer shelter.
  • GCC specifications. ADNOC, Aramco, Dolphin and OQGN set their limits in gas sales agreements that are not published. Take the limit from your contract.

Frequently asked questions

Where is water dew point measured in a gas plant?

At the TEG contactor outlet, at the molecular-sieve dryer outlet before NGL recovery, at custody transfer or pipeline entry, and at the fuel gas skid for gas turbines.

What is a typical pipeline water specification?

US pipelines commonly allow 7 lb/MMscf (about 147 ppmv). European networks under EN 16726 use −8 °C at 70 bar. In the GCC the limit is set in each gas sales agreement.

Why does a molecular-sieve outlet need such a dry reading?

Cryogenic NGL recovery runs at about −84 °C, so water must be below 0.1 ppmv or it freezes in the cold box. A fast trace-moisture analyzer detects bed breakthrough.

Does YORK supply analyzers it does not manufacture?

Yes. For points such as hydrocarbon dew point, H₂S, mercury and gas chromatography, YORK supplies an integrated system through its partner integration factory, together with the YORK instruments.

Planning analyzers for a gas plant?

Send us the process points, pressures and area classification, and we will propose the instruments and sampling systems.