Tap a numbered point. Swipe the diagram sideways on a phone.
How the process works
Raw gas from the wells arrives water-saturated and carries CO₂, H₂S and sometimes oxygen. The plant removes each of them in turn, and an analyzer after each step proves the step worked.
- Inlet separation. Slug catchers and separators remove free liquids. Inlet water is calculated, not measured, because the gas is saturated.
- Acid gas removal. An amine contactor absorbs CO₂ and H₂S down to the pipeline limit, or to ppm levels when the gas goes on to LNG.
- Dehydration. For pipeline gas, triethylene glycol (TEG) absorbs water in a contactor. Where the gas goes to cryogenic NGL recovery, molecular-sieve beds dry it far deeper, to below 0.1 ppmv.
- NGL recovery. A turbo-expander cold box condenses ethane and heavier liquids. Mercury guard beds protect its aluminium exchangers.
- Compression and custody transfer. Residue gas is compressed and metered against the sales contract: water dew point, hydrocarbon dew point, O₂, CO₂, H₂S and heating value.
- Fuel gas. A side stream feeds gas turbines, which need the gas superheated above its dew points.
Measurement points at a glance
| # | Point | Measures | Typical value / limit | Recommended solution |
|---|---|---|---|---|
| 1 | Plant inlet / gathering header | Oxygen (ppm) | Case study: 90–100 ppmv at the inlet damaged the amine; the pipeline limit was < 2,000 ppmv | DPSS-61XX; Integrated system: trace O₂ analyzer qualified for wet sour gas |
| 2 | Amine contactor outlet | CO₂ (%) | Pipeline: ≤ 2.0 vol% (US tariff example), ≤ 2.0 mol% (UK network entry) | Integrated system: explosion-proof NDIR CO₂ analyzer with a 0–5 vol % range |
| 3 | Amine contactor outlet | H₂S and total sulfur | US tariff example: 0.5 grain/100 scf (≈ 8 ppmv); UK network entry: ≤ 5 mg/m³ | Integrated system: H₂S analyzer (lead-acetate tape or UV) |
| 4 | TEG contactor outlet | Water content / water dew point at line pressure | Typically 7 lb/MMscf (≈ 147 ppmv) in US pipelines; −8 °C at 70 bar under EN 16726 | DPT830, DPT990-EX, DPSS-61XX, DPT-600 Plus-EX |
| 5 | Molecular-sieve dryer outlet | Trace water (ppmv) | < 0.1 ppmv (≈ −90 °C frost point at 1 atm) | DPT830, DPT990-EX |
| 6 | Mercury guard bed outlet | Mercury | Down to 0.01 µg/Nm³ reported | Integrated system: mercury analyzer (cold-vapour atomic absorption or fluorescence) |
| 7 | Custody transfer / pipeline entry | Water dew point at stated pressure | US: ≤ 7 lb/MMscf (some ≤ 4); EU: −8 °C at 70 bar; UK: −10 °C at 85 barg. GCC: per the gas sales agreement | DPT830, DPT990-EX |
| 8 | Custody transfer / pipeline entry | Hydrocarbon dew point | UK entry: ≤ −2 °C at any pressure up to 85 bar; other networks −10 °C at 54–60 bar | Integrated system: automatic hydrocarbon dew point analyzer, or calculation from process GC (ISO 23874) |
| 9 | Custody transfer / pipeline entry | Oxygen | US tariff example ≤ 0.2 vol%; EN 16726: 10 ppm for sensitive users; UK entry ≤ 0.2 % above 38 barg | PGA500-EX, PGA500 |
| 10 | Custody transfer / pipeline entry | Composition, heating value, Wobbe index, total sulfur | Calculated from the mole-fraction composition per ISO 6976 | Integrated system: process gas chromatograph (C6+/C9+) with sulfur detection |
| 11 | Gas turbine fuel gas skid | Water dew point | Fuel must be supplied at least 11 °C (20 °F) above its highest dew point (one turbine OEM specification) | DPT810, DPT990-EX |
Values are typical figures from published specifications and technical literature. Your contract, licensor or plant specification always governs.
Getting reliable readings
- State the pressure. A water dew point means nothing without its pressure basis. Specifications quote it at line pressure, for example −8 °C at 70 bar.
- Glycol and methanol. Vapour from the TEG unit or from hydrate-inhibitor injection biases metal-oxide sensors. Use a coalescing filter and sample upstream of methanol injection.
- Heavy hydrocarbons. In rich gas, hydrocarbons can condense on a chilled mirror before water does. The reading can then be the hydrocarbon dew point, not the water dew point. Measure water dew point with a metal-oxide or TDLAS analyzer, and hydrocarbon dew point with a separate analyzer.
- Hazardous area. Most of these points are in Zone 1 or Zone 2, so use explosion-proof analyzers or a certified analyzer shelter.
- GCC specifications. ADNOC, Aramco, Dolphin and OQGN set their limits in gas sales agreements that are not published. Take the limit from your contract.
References
- Gas Quality section of the Algonquin FERC TariffMass.gov
- Draft Comparison of Pipeline Natural Gas Quality Specifications (R03035)NAESB
- EASEE-gas CBP Hydrogen Quality Specification, additional material (EN 16726 limits)ENTSOG
- Network Entry Gas Quality SpecificationCadent Gas
- PEH: Gas Treating and ProcessingSPE PetroWiki
- Dehydration process (lecture slides)Seoul National University OCW
- Santa Barbara Extraction Plant: mol-sieve dehydration and mercury removalOSTI
- Texas gas plant faces ongoing battle with oxygen contaminationOil & Gas Journal
- Effect of oxygen on the internal corrosion of natural gas pipelinesOSTI
- ISO 18453:2004 Natural gas: correlation between water content and water dew pointISO
- ISO 23874:2006 Natural gas: GC requirements for hydrocarbon dewpoint calculationCSA Group
- ISO 6976:2016 Natural gas: calculation of calorific values, density and Wobbe indicesSIS
- Hydrocarbon dew point specifications by country, STET vol. 77 (2022)EDP Sciences
- OEM natural gas fuel specification (utility RFP appendix)Public Service Company of Oklahoma
Frequently asked questions
Where is water dew point measured in a gas plant?
At the TEG contactor outlet, at the molecular-sieve dryer outlet before NGL recovery, at custody transfer or pipeline entry, and at the fuel gas skid for gas turbines.
What is a typical pipeline water specification?
US pipelines commonly allow 7 lb/MMscf (about 147 ppmv). European networks under EN 16726 use −8 °C at 70 bar. In the GCC the limit is set in each gas sales agreement.
Why does a molecular-sieve outlet need such a dry reading?
Cryogenic NGL recovery runs at about −84 °C, so water must be below 0.1 ppmv or it freezes in the cold box. A fast trace-moisture analyzer detects bed breakthrough.
Does YORK supply analyzers it does not manufacture?
Yes. For points such as hydrocarbon dew point, H₂S, mercury and gas chromatography, YORK supplies an integrated system through its partner integration factory, together with the YORK instruments.
Planning analyzers for a gas plant?
Send us the process points, pressures and area classification, and we will propose the instruments and sampling systems.