Saudi Arabia · power transmission
SF₆ moisture and dew point analyzers for switchgear in Saudi Arabia
YORK Instrument supplies the DM9600P portable chilled mirror hygrometer for measuring moisture in SF₆ and SF₆-free gas-insulated switchgear (GIS) and circuit breakers in Saudi Arabia. Enquiries from the Kingdom are handled by our regional team in Dubai.
At a glance
| Instrument | DM9600P portable chilled mirror hygrometer, battery powered, SD card logging |
|---|---|
| Range | −60 °C frost point to +20 °C dew point (about 11 ppmV at atmospheric pressure at the low end) |
| Reference limits | IEC 60480:2019 re-use: below 200 ppmV (about −36 °C frost point at 1 atm) · IEC 60376 new gas: 25 mg/kg |
| Gases | SF₆ and non-flammable SF₆-free insulating gases, in switch rooms that are not hazardous areas |
| Sample pressure | Up to 4 barg at the instrument; built-in pressure sensor |
| Delivery | 6 to 8 weeks from order confirmation, shipped from the factory with export documents |
| Warranty | 12 months from shipment |
| Contact | Dubai regional team · dubai@yorkinstrument.com · +971 55 137 4866 (WhatsApp) |
Which YORK instrument for switchgear work?
| Task | Instrument | Note |
|---|---|---|
| Commissioning and maintenance checks of GIS compartments and breakers | DM9600P | Portable, −60 °C frost point, logs to SD card |
| Lower frost points, portable | DM9600PL | To −70 °C frost point |
| Laboratory reference for gas samples and transmitter checks | DM9900 | To −90 °C frost point |
| Converting a reading to ppmV, mg/kg or dew point at filling pressure | SF₆ moisture calculator | Free tool with IEC 60480 and IEC 60376 checks |
Measuring SF₆ moisture on site
- Most portable checks are made after the gas has expanded to atmospheric pressure. The dew point inside the compartment at filling pressure is higher; convert with the SF₆ moisture calculator before comparing with a condensation limit.
- Use short stainless steel lines and fittings designed for SF₆, and keep the sample at 4 barg or less at the instrument.
- Let the mirror reach a stable frost layer before recording. Below 0 °C a chilled mirror can briefly hold supercooled dew.
- Recover the sample gas rather than venting it. Ask our team about the connection and recovery arrangement for your equipment.
- For SF₆-free gases such as C4-FN mixtures and technical air, see the SF₆-free switchgear guide.
How to buy in Saudi Arabia
Send the equipment type (GIS, breaker, RMU), the gas, the filling pressure, the limit you work to and the quantity to our Dubai team. We reply with a quotation for the DM9600P or another YORK instrument.
Instruments are shipped from the factory with export documents. Import clearance in Saudi Arabia, including SABER registration, is arranged with the importer. We are appointing a distribution partner in Saudi Arabia; until then, quotations are made directly by our regional team.
Also see: all dew point meters and oxygen analyzers in Saudi Arabia · power generation and grid measurement points.
Frequently asked questions
Who supplies SF₆ moisture analyzers in Saudi Arabia?
YORK Instrument supplies the DM9600P portable chilled mirror hygrometer for SF₆ and SF₆-free switchgear in Saudi Arabia. Quotations come from YORK's regional team in Dubai (dubai@yorkinstrument.com, WhatsApp +971 55 137 4866). Delivery is 6 to 8 weeks from order confirmation.
What is the moisture limit for SF₆ under IEC 60480?
IEC 60480:2019 sets a water limit below 200 µL/L (ppmV) for SF₆ that is to be re-used. At atmospheric pressure this is about −36 °C frost point. New technical-grade SF₆ under IEC 60376 is limited to 25 mg/kg. In-service limits are set by the switchgear manufacturer.
Why use a chilled mirror for SF₆?
A chilled mirror measures the dew or frost point directly as a temperature, so the reading does not depend on a sensor calibration curve for SF₆. The DM9600P reads down to −60 °C frost point, below the IEC 60480 and IEC 60376 limits.
Can the DM9600P be used on SF₆-free switchgear gases?
It is used on non-flammable insulating gases, including SF₆-free mixtures, in substation switch rooms that are not hazardous areas. Send the gas composition with your enquiry so we can confirm the application.
What happens to the sample gas?
SF₆ is a potent greenhouse gas. Use fittings designed for SF₆ and recover the sample gas rather than venting it. Ask our team about the connection and recovery arrangement for your equipment.
Ask for a quotation
Tell us the equipment, gas, filling pressure and limit, and our Dubai team will propose the instrument.