H₂O · Chilled mirror

YORK DM9900 rack-mount chilled mirror hygrometer, reference grade

The DM9900 is a rack-mount, reference-grade chilled mirror hygrometer for calibration laboratories and metrology institutes, from −90 °C frost point to +20 °C dew point, with accuracy better than ±0.2 °C near −90 °C frost point. It measures dew point directly, so it is used as the reference against which dew point transmitters and portable meters are calibrated.

YORK DM9900 – Rack-mount chilled mirror hygrometer, reference grade
ModelDM9900
TypeRack-mount chilled mirror hygrometer, reference grade
Range−90 °C frost point to +20 °C dew point
AccuracyBetter than ±0.2 °C near −90 °C frost point
PrincipleChilled mirror
CoolingRefrigeration system
Gas connectionsVCR fittings
Built inPressure sensor, electronic flow meter
Outputs and dataThree analog outputs, alarm output, SD card logging, USB-C and RS485 (Modbus RTU)
WeightAbout 40 kg
UseNon-flammable gases in safe areas
Calibration certificateAvailable (chargeable)
Lead time6 to 8 weeks
Regional contactDubai, UAE — covers the GCC

Product catalog (PDF) · certificate copies are sent with quotations.

Where it is used

UserRole of the DM9900
Calibration laboratoriesReference hygrometer on a humidity calibration bench; see dew point calibration laboratories
National metrology institutesLow dew point reference for transfer standards
Industrial gas producersReference checks of trace moisture in nitrogen, argon and oxygen
Instrument service companiesChecking dew point transmitters and portable meters before they return to site

A complete calibration bench

ItemYORK option
Dry gas sourceDC1000, dry air below 1 ppmV (−75 °C dew point)
Low humidity generatorDC2000, stability better than ±0.2 °C frost point
Reference hygrometerDM9900
Complete rack systemYKDC220

The procedure is described in how to calibrate a dew point sensor.

DM9900 or another YORK chilled mirror?

If you need…Choose
The lowest range and reference accuracy in the laboratoryDM9900
A rack-mount instrument to −80 °C frost pointDM9800
A portable reference for site checks and SF₆DM9600P or DM9600PL
High dew points and climatic chambersDM9200

Ordering in the UAE and GCC

Send your enquiry to our Dubai team with:

  • the range and points you want to calibrate;
  • the gases (air, nitrogen, other);
  • whether you need a calibration certificate, and the lowest point;
  • quantity.

We reply with a quotation for the DM9900. Instruments are shipped from the factory with export documents, 6 to 8 weeks from order confirmation. A calibration certificate is available at extra cost; the price depends on the lowest calibration point. The DM9900 is a low-pressure instrument for non-flammable gases in safe areas; it is not explosion-proof and is not intended for natural gas on site.

See all dew point meters and analyzers available in the UAE.

Questions about the DM9900

What is the accuracy of the DM9900?

Better than ±0.2 °C near −90 °C frost point.

Can YORK provide a calibration certificate for the DM9900?

Yes, at extra cost. The price depends on the lowest calibration point. For accredited calibration, use an ISO/IEC 17025 laboratory; in the UAE laboratories are accredited by EIAC, in Saudi Arabia by SAAC.

What is the DM9900 used with in a calibration bench?

A dry gas source such as the DC1000 and a low humidity generator such as the DC2000, or the complete YKDC220 system.

Can the DM9900 be used for natural gas or other flammable gases?

No. YORK chilled mirror hygrometers are low-pressure instruments (up to 4 barg) and are not explosion-proof; they are for non-flammable gases in safe areas.

How do I get a quotation in the UAE?

Email dubai@yorkinstrument.com or WhatsApp +971 55 137 4866 with the range, calibration points and quantity.