H₂O · Chilled mirror
YORK DM9900 rack-mount chilled mirror hygrometer, reference grade
The DM9900 is a rack-mount, reference-grade chilled mirror hygrometer for calibration laboratories and metrology institutes, from −90 °C frost point to +20 °C dew point, with accuracy better than ±0.2 °C near −90 °C frost point. It measures dew point directly, so it is used as the reference against which dew point transmitters and portable meters are calibrated.

| Model | DM9900 |
|---|---|
| Type | Rack-mount chilled mirror hygrometer, reference grade |
| Range | −90 °C frost point to +20 °C dew point |
| Accuracy | Better than ±0.2 °C near −90 °C frost point |
| Principle | Chilled mirror |
| Cooling | Refrigeration system |
| Gas connections | VCR fittings |
| Built in | Pressure sensor, electronic flow meter |
| Outputs and data | Three analog outputs, alarm output, SD card logging, USB-C and RS485 (Modbus RTU) |
| Weight | About 40 kg |
| Use | Non-flammable gases in safe areas |
| Calibration certificate | Available (chargeable) |
| Lead time | 6 to 8 weeks |
| Regional contact | Dubai, UAE — covers the GCC |
Product catalog (PDF) · certificate copies are sent with quotations.
Where it is used
| User | Role of the DM9900 |
|---|---|
| Calibration laboratories | Reference hygrometer on a humidity calibration bench; see dew point calibration laboratories |
| National metrology institutes | Low dew point reference for transfer standards |
| Industrial gas producers | Reference checks of trace moisture in nitrogen, argon and oxygen |
| Instrument service companies | Checking dew point transmitters and portable meters before they return to site |
A complete calibration bench
| Item | YORK option |
|---|---|
| Dry gas source | DC1000, dry air below 1 ppmV (−75 °C dew point) |
| Low humidity generator | DC2000, stability better than ±0.2 °C frost point |
| Reference hygrometer | DM9900 |
| Complete rack system | YKDC220 |
The procedure is described in how to calibrate a dew point sensor.
DM9900 or another YORK chilled mirror?
| If you need… | Choose |
|---|---|
| The lowest range and reference accuracy in the laboratory | DM9900 |
| A rack-mount instrument to −80 °C frost point | DM9800 |
| A portable reference for site checks and SF₆ | DM9600P or DM9600PL |
| High dew points and climatic chambers | DM9200 |
Ordering in the UAE and GCC
Send your enquiry to our Dubai team with:
- the range and points you want to calibrate;
- the gases (air, nitrogen, other);
- whether you need a calibration certificate, and the lowest point;
- quantity.
We reply with a quotation for the DM9900. Instruments are shipped from the factory with export documents, 6 to 8 weeks from order confirmation. A calibration certificate is available at extra cost; the price depends on the lowest calibration point. The DM9900 is a low-pressure instrument for non-flammable gases in safe areas; it is not explosion-proof and is not intended for natural gas on site.
See all dew point meters and analyzers available in the UAE.
Questions about the DM9900
What is the accuracy of the DM9900?
Better than ±0.2 °C near −90 °C frost point.
Can YORK provide a calibration certificate for the DM9900?
Yes, at extra cost. The price depends on the lowest calibration point. For accredited calibration, use an ISO/IEC 17025 laboratory; in the UAE laboratories are accredited by EIAC, in Saudi Arabia by SAAC.
What is the DM9900 used with in a calibration bench?
A dry gas source such as the DC1000 and a low humidity generator such as the DC2000, or the complete YKDC220 system.
Can the DM9900 be used for natural gas or other flammable gases?
No. YORK chilled mirror hygrometers are low-pressure instruments (up to 4 barg) and are not explosion-proof; they are for non-flammable gases in safe areas.
How do I get a quotation in the UAE?
Email dubai@yorkinstrument.com or WhatsApp +971 55 137 4866 with the range, calibration points and quantity.