Desiccant dryer water load calculator

Enter flow, pressure and the inlet and outlet dew points. The tool gives the water removed and the minimum adsorbent mass per cycle.

YORK Instrument Middle East engineering team · Published 27 Nov 2026

LiveYORK · Dryer water load

Saturated gas: dew point = inlet temperature

Example value: use your adsorbent supplier's figure

Water removed
—kg/h
Water removed per day
—kg/day
Minimum adsorbent per tower
—kg
Inlet water
—
Outlet water
—
Water per cycle
—
Outlet atmospheric dew point
—

Method

Water mole fraction y = e(Td) / P, where e is the saturation vapour pressure at the pressure dew point (Sonntag 1990, over ice below 0 °C) and P is the absolute pressure. Water removed = (Q / 22.414) × [yin − (1 − yin)·yout/(1 − yout)] × 18.015 kg/h. Minimum adsorbent mass = water per cycle ÷ working capacity.

Limits

  • Ideal gas: suitable for air, nitrogen, hydrogen and CO₂ at moderate pressure, not for high-pressure natural gas.
  • The mass is a theoretical minimum. Add margins for the mass transfer zone and ageing as your adsorbent supplier recommends.
  • Regeneration water and purge gas are not included.

See the molecular sieve breakthrough guide and the ISO 8573-1 class checker.

Frequently asked questions

How much water does a 1000 Nm³/h air dryer at 7 bar(g) remove?

From air saturated at +35 °C down to a −40 °C pressure dew point, the dryer removes about 5.6 kg/h, or 135 kg per day. For an 8 h cycle and 10 % working capacity, each tower needs at least 451 kg of adsorbent before design margins.

How do I know a molecular sieve bed is close to breakthrough?

The outlet dew point starts to rise before the end of the cycle. Continuous dew point monitoring at each tower outlet catches breakthrough before moisture reaches the process. See the molecular sieve breakthrough guide.

Can I use this for natural gas?

Not at high pressure. Natural gas is far from ideal, so use the natural gas water content calculator (lb/MMscf) to get inlet and outlet water instead.

Monitoring air or gas dryers?

We supply in-line dew point transmitters and analyzers for dryer outlets, down to −110 °C.