H₂O · Dew point
YORK DPT-600 Plus portable dew point meter
The DPT-600 Plus is a battery-powered dew point meter for spot checks of compressed air, nitrogen and other dry gases, from −110 °C frost point to +20 °C dew point. Field engineers in the Gulf use it to audit compressed air dryers, confirm that a pipeline is dry after hydrotesting, and check nitrogen and industrial gas purity before a gas goes into service.

| Model | DPT-600 Plus |
|---|---|
| Type | Portable dew point meter |
| Range | −110 °C frost point to +20 °C dew point |
| Accuracy | ±2 °C dew point |
| Sensor | Nano-porous metal-oxide film |
| Sample handling | Built-in metering valve, flow meter and sensor desiccant cartridge |
| Sample pressure | Up to 4 barg; measure at reduced pressure and convert to line-pressure dew point |
| Gases | Gas phase only; fit a filter if natural gas carries glycol or methanol |
| Data and power | USB-C data interface; rechargeable battery |
| Hazardous areas | DPT-600 Plus-EX version (Ex ia IIC T4 Ga); certificate details are sent with quotations |
| Lead time | 6 to 8 weeks |
| Warranty | 12 months from shipment |
| Regional contact | Dubai, UAE — covers the GCC |
Product catalog (PDF) · certificate copies are sent with quotations.
Where it is used in the Gulf
| Job | What you check | Typical target |
|---|---|---|
| Compressed air audit | Pressure dew point after refrigerant and desiccant dryers | ISO 8573-1 class, for example class 2 (≤ −40 °C PDP); see the ISO 8573-1 air class tool |
| Pipeline and vessel dry-out | Dew point of the drying air or nitrogen leaving the line after hydrotest | The value in the project's drying procedure |
| Nitrogen generators and cylinders | Moisture in nitrogen for purging, blanketing and laser cutting | Per the gas specification |
| Desiccant and molecular sieve dryers | Outlet dew point after regeneration | Per the dryer design; see molecular sieve breakthrough |
| Natural gas spot checks | Water dew point at a sample point, measured at reduced pressure | Per the gas sales agreement; use the DPT-600 Plus-EX in hazardous areas |
| Battery dry rooms and glove boxes | Room or box dew point | Often −40 °C to −60 °C dew point or drier |
How to take a reading
- Reduce the sample to 4 barg or less, ideally close to atmospheric pressure.
- Connect with stainless steel tubing, as short as possible. Avoid plastic tubing for low dew points.
- Set the flow with the built-in metering valve and flow meter.
- Wait for the reading to settle. At −60 °C and below this takes much longer than at −20 °C.
- If you measured at reduced pressure, use the built-in conversion to report the dew point at line pressure, or the dew point calculator.
- After the measurement, close the sensor with the desiccant cartridge so it stays dry between jobs.
DPT-600 Plus or another YORK instrument?
| If you need… | Choose |
|---|---|
| Portable spot checks in a safe area | DPT-600 Plus |
| Portable checks in a hazardous area | DPT-600 Plus-EX |
| Continuous monitoring with outputs and alarms | DPT830 in-line analyzer |
| A portable reference, or SF₆ checks with a direct dew point measurement | DM9600P portable chilled mirror |
Ordering in the UAE and GCC
Send your enquiry to our Dubai team with:
- the gas and where it is measured;
- the expected dew point and line pressure;
- whether the measurement point is in a hazardous area;
- quantity.
We reply with a quotation for the DPT-600 Plus or DPT-600 Plus-EX. Instruments are shipped from the factory with export documents, 6 to 8 weeks from order confirmation. Metal-oxide sensors are typically recalibrated every 12 months; see how to calibrate a dew point sensor.
See all dew point meters and analyzers available in the UAE.
DPT-600 Plus compared with the CS Instruments DP 500 and SUTO S520
The CS Instruments DP 500 and the SUTO S520 are the portable dew point meters most often offered for compressed air in the Gulf. The table compares published specifications.
| YORK DPT-600 Plus | CS Instruments DP 500 | SUTO S520 | |
|---|---|---|---|
| Lowest dew point | −110 °C frost point | −80 °C | −100 °C (sensor A); −60 °C (sensor B) |
| Published accuracy | ±2 °C | ±0.5 °C from −10 to +50 °C; typically ±2 °C over the rest of the range | ±1 °C from 0 to +20 °C; ±2 °C from −70 to 0 °C; ±3 °C from −100 to −70 °C |
| Sensor | Nano-porous metal-oxide film | CS dew point sensor | QCM + polymer (sensor A); polymer (sensor B) |
| Sample pressure | Up to 4 barg; measure at reduced pressure and convert | Up to 50 bar(g) standard | Up to 16 bar(g); bypass chamber for low pressure |
| Hazardous-area version | Yes: DPT-600 Plus-EX (Ex ia IIC T4 Ga) | Not listed in the data sheet | Not listed in the data sheet |
| Data | USB-C data interface | Data logger, 16 GB card | Internal logger, up to 30 million data sets |
| Battery | Rechargeable | Li-ion, about 12 h | About 8 h |
Which one fits the job
- Measuring directly at compressed air line pressure and logging over days: the DP 500 and S520 connect at line pressure and have large internal loggers. The DPT-600 Plus takes the sample at reduced pressure and converts the reading to line pressure.
- Below −80 °C, for example molecular sieve dryer outlets or high-purity nitrogen and argon: the DPT-600 Plus reads to −110 °C frost point and the S520 with sensor A to −100 °C.
- Hazardous areas such as gas plants and refineries: the DPT-600 Plus-EX is the Ex ia version; the other two data sheets list no hazardous-area version.
Competitor data from each manufacturer's published data sheet (CS Instruments DP 500/510 data sheet; SUTO S520 data sheet, 2024 edition), checked in November 2026. Product names are trademarks of their owners. Check the current data sheet before ordering.
Questions about the DPT-600 Plus
What is the accuracy of the DPT-600 Plus?
±2 °C dew point, over a range of −110 °C frost point to +20 °C dew point.
Can the DPT-600 Plus measure at line pressure?
It accepts sample pressure up to 4 barg. For higher pressures, reduce the sample pressure, measure, and use the built-in conversion to report the line-pressure dew point.
Can I use the DPT-600 Plus in a hazardous area?
Use the DPT-600 Plus-EX, marked Ex ia IIC T4 Ga. Certificate details are sent with quotations. The standard DPT-600 Plus is for safe areas only.
Can it check pipeline dry-out after hydrotest?
Yes. It measures the dew point of the drying air or nitrogen leaving the line, down to −110 °C frost point. The acceptance value comes from the project's drying procedure.
How do I get a quotation in the UAE?
Email dubai@yorkinstrument.com or WhatsApp +971 55 137 4866 with the gas, dew point, pressure, area classification and quantity.
How does the DPT-600 Plus compare with the CS DP 500 and SUTO S520?
The DPT-600 Plus reads lower, to −110 °C frost point, against −80 °C for the DP 500 and −100 °C for the S520 with sensor A, and it has a DPT-600 Plus-EX version for hazardous areas, which the other two data sheets do not list. The DP 500 and S520 connect directly at compressed air line pressure (up to 50 and 16 bar(g)) and have large internal data loggers; the DPT-600 Plus measures at up to 4 barg and converts to line pressure.