H₂O · Dew point
YORK DPT830 in-line dew point analyzer
The DPT830 is a fixed, in-line dew point analyzer for continuous monitoring, from −110 °C frost point to +20 °C dew point. It is typically installed at the outlet of compressed air and gas dryers, on nitrogen generators, in battery dry rooms and on process gas lines in safe areas or analyzer shelters, with outputs to the plant control system and alarm relays.

| Model | DPT830 |
|---|---|
| Type | In-line dew point analyzer |
| Range | −110 °C frost point to +20 °C dew point |
| Sensor | Nano-porous metal-oxide film |
| Outputs | Analog output, digital output, alarm relay |
| Power | AC or DC supply |
| Sample pressure | Up to 4 barg; measure at reduced pressure and convert to line-pressure dew point |
| Gases | Gas phase only; fit a filter if natural gas carries glycol or methanol |
| Hazardous areas | Use the DPT990-EX explosion-proof version |
| Lead time | 6 to 8 weeks |
| Warranty | 12 months from shipment |
| Regional contact | Dubai, UAE — covers the GCC |
Product catalog (PDF) · certificate copies are sent with quotations.
Where it is installed
| Location | Why dew point is monitored |
|---|---|
| Desiccant and refrigerant dryer outlets | Alarm when the dryer stops meeting the ISO 8573-1 class; see compressed air dew point |
| Nitrogen generators | Confirm product nitrogen is dry before it goes to purging, blanketing or packaging |
| Battery dry rooms and glove boxes | Continuous room or box dew point with alarm; see dry rooms and glove boxes |
| Plastic resin dryers | Dew point of the dry air reaching hygroscopic resins; see resin drying |
| Molecular sieve and gas dryer outlets in a safe area or shelter | Detect breakthrough and confirm regenerated beds; see molecular sieve breakthrough |
Installation notes
- Take the sample through a pressure reducer to 4 barg or less and measure close to atmospheric pressure; use the conversion to report line-pressure dew point.
- Use short stainless steel sample lines and keep a continuous flow, with a bypass if needed.
- Allow dry-down time after installation before trusting trace readings.
- Where the point is in a classified area, use the DPT990-EX, or install the DPT830 in a safe area or analyzer shelter with the sample line brought to it.
DPT830 or another YORK instrument?
| If you need… | Choose |
|---|---|
| Continuous monitoring in a safe area | DPT830 |
| Continuous monitoring in a hazardous area | DPT990-EX |
| A compact transmitter | DPT810 |
| Portable spot checks | DPT-600 Plus |
Ordering in the UAE and GCC
Send your enquiry to our Dubai team with:
- the gas and where it is measured;
- the expected dew point and line pressure;
- whether the measurement point is in a hazardous area;
- quantity.
We reply with a quotation for the DPT830. Instruments are shipped from the factory with export documents, 6 to 8 weeks from order confirmation. Metal-oxide sensors are typically recalibrated every 12 months; see how to calibrate a dew point sensor.
See all dew point meters and analyzers available in the UAE.
Questions about the DPT830
What outputs does the DPT830 have?
Analog output, digital output and alarm relay, with AC or DC power supply.
Can the DPT830 be installed in a hazardous area?
No. Use the DPT990-EX explosion-proof dew point analyzer, or install the DPT830 in a safe area or analyzer shelter with the sample line brought to it.
What is the maximum sample pressure?
4 barg. Measure at reduced pressure and use the conversion to report the dew point at line pressure.
How often does the DPT830 need calibration?
Typically every 12 months, and more often in dirty or wet gas.
How do I get a quotation in the UAE?
Email dubai@yorkinstrument.com or WhatsApp +971 55 137 4866 with the gas, dew point, pressure, area classification and quantity.