Process guide · animated
Dates: where to measure CO₂, oxygen and humidity in storage and packing
Follow the dates from receiving and CO₂ disinfestation into cold storage and out through the nitrogen packing line. Each numbered point shows what is measured, the typical condition, why it matters and the instrument that fits.
Tap a numbered point. Swipe the diagram sideways on a phone.
How a packing house handles dates
The Gulf is one of the world's largest date-producing regions. Packing houses use CO₂, cold and nitrogen to keep the fruit free of insects and fresh for export, and each of these depends on a measured gas concentration.
- Receiving. Dates arrive from the farms in crates and are sorted.
- Disinfestation. Instead of chemical fumigants, some packers treat the dates with high CO₂ in a sealed chamber; organic dates rely on it.
- Cold storage. Dates keep for months at about 0 °C; fresh khalal dates can be held longer in a controlled atmosphere with raised CO₂.
- Packing. Dates are packed in boxes or trays flushed with nitrogen from an on-site generator, then sealed.
Measurement points at a glance
| # | Point | Measures | Typical condition | Recommended solution |
|---|---|---|---|---|
| 1 | CO₂ disinfestation chamber | CO₂ concentration (%) | Organic dates may be treated with 100 % CO₂ for 1–2 days (UC Davis); pressurised CO₂ systems are under development in Saudi Arabia | PGA520, PGA620 |
| 2 | CO₂ disinfestation chamber | Residual oxygen | Falls as CO₂ displaces the air; confirms the purge is complete before the exposure time starts | PGA530, POA300 |
| 3 | Controlled-atmosphere cold room | CO₂ in the room atmosphere (%) | Khalal Barhee dates: about 20 % CO₂ in air at 0 °C and 90–95 %RH extended storage to up to 26 weeks, against 7 weeks in air (UC Davis) | PGA520 |
| 4 | Cold room temperature and humidity | Dew point and relative humidity | Dates keep 6–12 months at 0 °C; fresh khalal dates are held at 90–95 %RH. At 0 °C and 90 %RH the dew point is about −1.4 °C | DM9200 |
| 5 | Packed boxes after sealing | Residual oxygen in the pack | Tamar dates are packed under nitrogen to exclude oxygen; the residual oxygen target is set by the packer | POA200, POA300 |
| 6 | Nitrogen generator outlet | Nitrogen purity (residual oxygen) | Set to the purity the packing line needs; membrane and PSA units drift as they age | PGA530, POA300 |
Values are taken from published postharvest research. Your own process validation and food safety plan always govern.
Getting reliable readings
- Safety first. High CO₂ and nitrogen-rich rooms are asphyxiation hazards; monitor before entry.
- Measure, then time. Start the disinfestation exposure time only when the target CO₂ is reached.
- Use portable checks. A portable oxygen analyzer covers packs, chambers and the generator in turn.
- Keep cold rooms honest. Check room humidity sensors against a reference before the main season.
References
- Date: recommendations for maintaining postharvest qualityUC Davis Postharvest Research and Extension Center
- Design and efficacy evaluation of a modern automated controlled atmosphere system for pest management in stored datesJournal of Stored Products Research · King Faisal University
Frequently asked questions
How are dates disinfested without fumigants?
Organic dates may be treated with 100 % CO₂ for one to two days in a sealed chamber; pressurised CO₂ systems that work faster are being developed. CO₂ and oxygen analyzers confirm the atmosphere during the treatment.
What storage conditions suit dates?
About 0 °C keeps dates for 6 to 12 months; fresh khalal dates are held at 90–95 %RH, and a controlled atmosphere with raised CO₂ can extend their life.
Why measure oxygen in date packs?
Nitrogen packing excludes oxygen to slow browning and stop insects. A spot check after sealing confirms the flush works.
Running a date packing house?
Tell us about your chambers, cold rooms and packing lines, and we will propose CO₂, oxygen and humidity instruments.