YORK PGA530 in-line percent oxygen analyzer

The PGA530 is an in-line oxygen analyzer for continuous monitoring from 0 to 100% O₂. It is installed on PSA nitrogen and oxygen generators, on inert gas supplies and on blanketing systems in safe areas, with outputs to the control system and alarm relays.

YORK PGA530 – In-line percent oxygen analyzer
ModelPGA530
TypeIn-line percent oxygen analyzer
Range0 to 100% O₂
PrincipleElectrochemical
OutputsAnalog output, digital output, alarm relay
PowerAC or DC supply
Not suitable forCO₂ background and acid gases (H₂S, HCl, SO₂)
Hazardous areasFor up to 25% O₂ in hazardous areas, use the PGA500-EX
Lead time6 to 8 weeks
Warranty12 months from shipment
Regional contactDubai, UAE — covers the GCC

Product catalog (PDF) · certificate copies are sent with quotations.

Where it is installed

LocationWhy oxygen is monitored
PSA nitrogen generatorsAlarm when residual O₂ rises above the set point
PSA oxygen generatorsContinuous purity of the product oxygen
Blanketing and inertingOxygen in the blanket gas; see process oxygen and inerting
Glove boxes and dry rooms at percent levelOxygen during purge-down; see dry rooms and glove boxes

Installation notes

  • Install in a safe area and keep a continuous sample flow.
  • Set the alarm relay at the process limit and wire the analog output to the control system.
  • Do not install in CO₂ or acid gas service; use a paramagnetic analyzer for gas containing CO₂.
  • For ppm levels use the PGA500.

PGA530 or another YORK oxygen analyzer?

If you need…Choose
Continuous percent O₂ in a safe areaPGA530
Continuous trace O₂PGA500
Continuous O₂ up to 25% in a hazardous areaPGA500-EX
Portable percent O₂ checksPOA300

Ordering in the UAE and GCC

Send your enquiry to our Dubai team with:

  • the gas and where it is measured;
  • the expected oxygen range;
  • whether the gas contains CO₂, acid gases (H₂S, HCl, SO₂), hydrogen or hydrocarbons;
  • whether the measurement point is in a hazardous area;
  • quantity.

We reply with a quotation for the PGA530. Instruments are shipped from the factory with export documents, 6 to 8 weeks from order confirmation. Electrochemical cells are consumables and are replaced periodically.

See all oxygen analyzers available in the UAE.

Questions about the PGA530

What is the range of the PGA530?

0 to 100% O₂, electrochemical.

What outputs does the PGA530 have?

Analog output, digital output and alarm relay, with AC or DC power supply.

Is there an explosion-proof percent oxygen analyzer?

For up to 25% O₂ in hazardous areas, use the PGA500-EX. Certificate details are sent with quotations.

Can the PGA530 measure oxygen in CO₂?

No. Use a paramagnetic analyzer for gas containing CO₂.

How do I get a quotation in the UAE?

Email dubai@yorkinstrument.com or WhatsApp +971 55 137 4866 with the gas, oxygen range, background components and quantity.