O₂ · Oxygen
YORK PGA530 in-line percent oxygen analyzer
The PGA530 is an in-line oxygen analyzer for continuous monitoring from 0 to 100% O₂. It is installed on PSA nitrogen and oxygen generators, on inert gas supplies and on blanketing systems in safe areas, with outputs to the control system and alarm relays.

| Model | PGA530 |
|---|---|
| Type | In-line percent oxygen analyzer |
| Range | 0 to 100% O₂ |
| Principle | Electrochemical |
| Outputs | Analog output, digital output, alarm relay |
| Power | AC or DC supply |
| Not suitable for | CO₂ background and acid gases (H₂S, HCl, SO₂) |
| Hazardous areas | For up to 25% O₂ in hazardous areas, use the PGA500-EX |
| Lead time | 6 to 8 weeks |
| Warranty | 12 months from shipment |
| Regional contact | Dubai, UAE — covers the GCC |
Product catalog (PDF) · certificate copies are sent with quotations.
Where it is installed
| Location | Why oxygen is monitored |
|---|---|
| PSA nitrogen generators | Alarm when residual O₂ rises above the set point |
| PSA oxygen generators | Continuous purity of the product oxygen |
| Blanketing and inerting | Oxygen in the blanket gas; see process oxygen and inerting |
| Glove boxes and dry rooms at percent level | Oxygen during purge-down; see dry rooms and glove boxes |
Installation notes
- Install in a safe area and keep a continuous sample flow.
- Set the alarm relay at the process limit and wire the analog output to the control system.
- Do not install in CO₂ or acid gas service; use a paramagnetic analyzer for gas containing CO₂.
- For ppm levels use the PGA500.
PGA530 or another YORK oxygen analyzer?
| If you need… | Choose |
|---|---|
| Continuous percent O₂ in a safe area | PGA530 |
| Continuous trace O₂ | PGA500 |
| Continuous O₂ up to 25% in a hazardous area | PGA500-EX |
| Portable percent O₂ checks | POA300 |
Ordering in the UAE and GCC
Send your enquiry to our Dubai team with:
- the gas and where it is measured;
- the expected oxygen range;
- whether the gas contains CO₂, acid gases (H₂S, HCl, SO₂), hydrogen or hydrocarbons;
- whether the measurement point is in a hazardous area;
- quantity.
We reply with a quotation for the PGA530. Instruments are shipped from the factory with export documents, 6 to 8 weeks from order confirmation. Electrochemical cells are consumables and are replaced periodically.
Questions about the PGA530
What is the range of the PGA530?
0 to 100% O₂, electrochemical.
What outputs does the PGA530 have?
Analog output, digital output and alarm relay, with AC or DC power supply.
Is there an explosion-proof percent oxygen analyzer?
For up to 25% O₂ in hazardous areas, use the PGA500-EX. Certificate details are sent with quotations.
Can the PGA530 measure oxygen in CO₂?
No. Use a paramagnetic analyzer for gas containing CO₂.
How do I get a quotation in the UAE?
Email dubai@yorkinstrument.com or WhatsApp +971 55 137 4866 with the gas, oxygen range, background components and quantity.