O₂ · Oxygen
YORK POA300 portable percent oxygen analyzer
The POA300 is a battery-powered oxygen analyzer for spot checks from 0 to 100% O₂. It is used to check the output of PSA nitrogen and oxygen generators, confirm inerting and purging at percent levels, and verify shielding and process gases in safe areas.

| Model | POA300 |
|---|---|
| Type | Portable percent oxygen analyzer |
| Range | 0 to 100% O₂ |
| Principle | Electrochemical |
| Sample handling | Built-in metering valve and flow meter |
| Data and power | USB-C data interface; rechargeable battery |
| Not suitable for | CO₂ background and acid gases (H₂S, HCl, SO₂); use the POA3500 in gas containing CO₂ |
| Areas | Safe areas |
| Lead time | 6 to 8 weeks |
| Warranty | 12 months from shipment |
| Regional contact | Dubai, UAE — covers the GCC |
Product catalog (PDF) · certificate copies are sent with quotations.
Where it is used
| Job | What you check |
|---|---|
| PSA nitrogen generators | Residual oxygen at percent level in product nitrogen |
| PSA oxygen generators | Oxygen purity of the product gas |
| Inerting and purging | Oxygen in vessels and lines before and during work; see process oxygen and inerting |
| Welding and cutting gases | Oxygen in shielding and purge gases |
Good practice
- Purge the sample line and set a steady flow with the metering valve before reading.
- Check the reading in air (20.9% O₂) before a job.
- Do not use the POA300 in CO₂ or acid gases.
- For trace levels below about 1% O₂, use the POA200 trace analyzer.
POA300 or another YORK oxygen analyzer?
| If you need… | Choose |
|---|---|
| Portable percent O₂ checks | POA300 |
| Portable trace O₂ (ppm) checks | POA200 |
| O₂ in gas containing CO₂ | POA3500 paramagnetic |
| Continuous percent O₂ | PGA530 in-line |
Ordering in the UAE and GCC
Send your enquiry to our Dubai team with:
- the gas and where it is measured;
- the expected oxygen range;
- whether the gas contains CO₂, acid gases (H₂S, HCl, SO₂), hydrogen or hydrocarbons;
- whether the measurement point is in a hazardous area;
- quantity.
We reply with a quotation for the POA300. Instruments are shipped from the factory with export documents, 6 to 8 weeks from order confirmation. Electrochemical cells are consumables and are replaced periodically.
Questions about the POA300
What is the range of the POA300?
0 to 100% O₂, electrochemical.
Can the POA300 measure oxygen in CO₂?
No. Use the POA3500 paramagnetic analyzer in gas containing CO₂.
Can the POA300 measure ppm oxygen?
For ppm levels use the POA200, which covers 0.01 ppm to 25% O₂.
Can the POA300 be used in a hazardous area?
Use it in safe areas.
How do I get a quotation in the UAE?
Email dubai@yorkinstrument.com or WhatsApp +971 55 137 4866 with the gas, oxygen range, background components and quantity.