O₂ · Oxygen

YORK POA300 portable percent oxygen analyzer

The POA300 is a battery-powered oxygen analyzer for spot checks from 0 to 100% O₂. It is used to check the output of PSA nitrogen and oxygen generators, confirm inerting and purging at percent levels, and verify shielding and process gases in safe areas.

YORK POA300 – Portable percent oxygen analyzer
ModelPOA300
TypePortable percent oxygen analyzer
Range0 to 100% O₂
PrincipleElectrochemical
Sample handlingBuilt-in metering valve and flow meter
Data and powerUSB-C data interface; rechargeable battery
Not suitable forCO₂ background and acid gases (H₂S, HCl, SO₂); use the POA3500 in gas containing CO₂
AreasSafe areas
Lead time6 to 8 weeks
Warranty12 months from shipment
Regional contactDubai, UAE — covers the GCC

Product catalog (PDF) · certificate copies are sent with quotations.

Where it is used

JobWhat you check
PSA nitrogen generatorsResidual oxygen at percent level in product nitrogen
PSA oxygen generatorsOxygen purity of the product gas
Inerting and purgingOxygen in vessels and lines before and during work; see process oxygen and inerting
Welding and cutting gasesOxygen in shielding and purge gases

Good practice

  • Purge the sample line and set a steady flow with the metering valve before reading.
  • Check the reading in air (20.9% O₂) before a job.
  • Do not use the POA300 in CO₂ or acid gases.
  • For trace levels below about 1% O₂, use the POA200 trace analyzer.

POA300 or another YORK oxygen analyzer?

If you need…Choose
Portable percent O₂ checksPOA300
Portable trace O₂ (ppm) checksPOA200
O₂ in gas containing CO₂POA3500 paramagnetic
Continuous percent O₂PGA530 in-line

Ordering in the UAE and GCC

Send your enquiry to our Dubai team with:

  • the gas and where it is measured;
  • the expected oxygen range;
  • whether the gas contains CO₂, acid gases (H₂S, HCl, SO₂), hydrogen or hydrocarbons;
  • whether the measurement point is in a hazardous area;
  • quantity.

We reply with a quotation for the POA300. Instruments are shipped from the factory with export documents, 6 to 8 weeks from order confirmation. Electrochemical cells are consumables and are replaced periodically.

See all oxygen analyzers available in the UAE.

Questions about the POA300

What is the range of the POA300?

0 to 100% O₂, electrochemical.

Can the POA300 measure oxygen in CO₂?

No. Use the POA3500 paramagnetic analyzer in gas containing CO₂.

Can the POA300 measure ppm oxygen?

For ppm levels use the POA200, which covers 0.01 ppm to 25% O₂.

Can the POA300 be used in a hazardous area?

Use it in safe areas.

How do I get a quotation in the UAE?

Email dubai@yorkinstrument.com or WhatsApp +971 55 137 4866 with the gas, oxygen range, background components and quantity.