Liquefaction runs at about −160 °C. Anything that can freeze, such as water and CO₂, or attack aluminium exchangers, such as mercury, must be removed first. The analyzers prove each pretreatment step before the gas enters the cold box.
- Acid gas removal. An amine unit takes CO₂ down to 50 ppmv or less and H₂S below 4 ppmv, far deeper than pipeline gas needs.
- Dehydration. Molecular-sieve beds dry the gas to about 0.1 ppmv water. One bed adsorbs while the other regenerates.
- Mercury removal. A guard bed removes mercury to about 10 ng/Nm³ to protect brazed-aluminium exchangers.
- Liquefaction. The main cryogenic heat exchanger condenses the gas to LNG, which runs down to the storage tanks.
- Nitrogen rejection. Where the gas carries nitrogen, a cryogenic NRU removes it. Its feed needs the same deep drying and low CO₂.
- Loading. LNG is sampled, vaporised and analysed by GC for custody transfer. Ship tanks are gassed up after inerting until CO₂ is low enough.
Measurement points at a glance
| # | Point | Measures | Typical value / limit | Recommended solution |
|---|---|---|---|---|
| 1 | Acid gas removal outlet | Trace CO₂ | ≤ 50 ppmv | Integrated system: trace CO₂ analyzer (low-range NDIR or GC) |
| 2 | Acid gas removal outlet | H₂S | < 4 ppmv | Integrated system: H₂S analyzer (lead-acetate tape or UV) |
| 3 | Molecular-sieve dryer outlet / cold box inlet | Trace water (ppmv) | 0.1 ppmv or lower (≈ −90 °C frost point at 1 atm) | DPT830, DPT990-EX |
| 4 | Mercury guard bed outlet | Mercury | 10 ng/Nm³ | Integrated system: mercury analyzer (cold-vapour atomic absorption or fluorescence) |
| 5 | Nitrogen rejection unit feed | Trace water | Dried by molecular sieves to trace levels; the exact limit is set by the process licensor | DPT830, DPT990-EX |
| 6 | Nitrogen rejection unit feed | Trace CO₂ | 50–100 ppmv in a conventional double-column NRU; about 0.3 mol% with a pre-separation column | Integrated system: trace CO₂ analyzer (low-range NDIR or GC) |
| 7 | NRU nitrogen vent | Oxygen | No published limit: measure when the vented nitrogen is reused as inert gas | PGA530, POA3500 |
| 8 | LNG rundown / loading line | Composition and gross calorific value | Per the sales contract; sampled, vaporised and analysed by GC | Integrated system: LNG sampling and vaporiser system with process GC |
| 9 | Ship tanks: gassing-up after inerting | CO₂ (%) | Cleared when CO₂ falls below a set value, for example 0.1 % | Integrated system: portable CO₂ analyzer certified for gas carriers |
Values are typical figures from published specifications and technical literature. Your contract, licensor or plant specification always governs.
Getting reliable readings
- Trace water needs a clean sample path. At 0.1 ppmv, moisture released by tubing walls dominates. Use short electropolished lines, keep a steady purge flow and allow dry-down time.
- Watch bed breakthrough. A rising trend at the mol-sieve outlet gives warning before the cold box is affected. Fast response matters more here than the last decimal.
- Trace CO₂. The 50 ppmv limit needs a low-range analyzer. YORK supplies it as part of an integrated analyzer system.
- Hazardous area. Pretreatment and liquefaction are classified areas, so use explosion-proof analyzers or a certified analyzer shelter.
References
- The fundamentals of feed gas pretreatmentLNG Industry
- Selecting technologies for onshore LNG productionDigital Refining
- Santa Barbara Extraction Plant: mol-sieve dehydration and mercury removalOSTI
- Molecular sieve dehydration (webinar)PetroSkills
- Carbon dioxide-tolerant nitrogen rejection reduces costsGas Processing & LNG
- LNG Custody Transfer Handbook, 5th editionGIIGNL
- PEH: Gas Treating and ProcessingSPE PetroWiki
- ISO 18453:2004 Natural gas: correlation between water content and water dew pointISO
Frequently asked questions
How dry must gas be before LNG liquefaction?
Typically about 0.1 ppmv water, which is roughly a −90 °C frost point at atmospheric pressure. Molecular-sieve dryers reach it.
What CO₂ level is allowed in LNG feed gas?
About 50 ppmv after acid gas removal. Higher CO₂ solidifies and plugs the main cryogenic heat exchanger.
Why is mercury removed before liquefaction?
Mercury attacks brazed-aluminium heat exchangers. Guard beds take it down to about 10 ng/Nm³.
Which analyzer checks ship tanks after inerting?
A portable CO₂ analyzer. Gassing-up continues until CO₂ falls below the value set in the procedure, for example 0.1 %.
Planning analyzers for an LNG train?
Send us the points, pressures and area classification, and we will propose the instruments and sampling systems.