Fabs use bulk nitrogen, argon, oxygen and hydrogen at sub-ppb impurity levels. YORK instruments screen incoming gas, watch purifiers and check CDA and house nitrogen; ppb and ppt certification uses dedicated trace analyzers.
- Bulk supply. Liquid gases from on-site tanks are vaporized; hydrogen often arrives by tube trailer.
- Incoming QC. Each delivery is screened before it reaches the purifier.
- Purification. Point-of-entry purifiers take moisture, oxygen, CO₂ and hydrocarbons down to the sub-ppb level.
- Distribution. Electropolished stainless lines and valve manifold boxes carry the gas to each tool.
- Utilities. Clean dry air and house nitrogen feed pneumatic valves, purges and inerting across the fab.
Measurement points at a glance
| # | Point | Measures | Typical value / limit | Recommended solution |
|---|---|---|---|---|
| 1 | Incoming tube trailer / bulk tank check | Moisture and oxygen (screening) | Before the purifier, moisture can exceed 10 ppm | DPT830, POA200 |
| 2 | Purifier outlet (breakthrough watch) | Moisture and oxygen (screening) | Should be below the analyzer floor; any rise signals breakthrough | DPT830, POA200 |
| 3 | Bulk distribution after the purifier | H₂O, O₂, CO₂, CH₄ | Below 1 ppb; industry roadmap target below 100 ppt | Integrated system: atmospheric-pressure ionization mass spectrometer (APIMS), cavity ring-down spectroscopy (CRDS) or a specialised trace GC |
| 4 | Point of use at the tool | H₂O, O₂, CO₂, CH₄ | Sub-ppb; consistency at the point of use matters more than the bulk number | Integrated system: APIMS, CRDS or specialised trace GC |
| 5 | Clean dry air (CDA) dryer outlet | Pressure dew point | Set by the fab specification | DPT830, DPT810 |
| 6 | House nitrogen generator outlet | Residual oxygen | Set by the fab specification | POA200, PGA500 |
Values are typical figures from published specifications and technical literature. Your contract, licensor or plant specification always governs.
Practical notes
- Know the floor. A trace oxygen analyzer reading to 0.01 ppm and a −110 °C frost point sensor are good screening tools, but they cannot certify ppt-level gas.
- Moisture lingers. Moisture adsorbs on tube walls and is released slowly, so dry-down after maintenance takes time.
- Materials matter. Polymer parts such as PTFE can release moisture for a long time; use electropolished stainless steel in the sample path.
References
- Bulk gas purity and APIMS measurementSolid State Technology / Semiconductor Digest
Frequently asked questions
Can YORK analyzers certify semiconductor-grade gas?
No. Sub-ppb and ppt certification needs APIMS, CRDS or specialised trace GC, which YORK can supply as an integrated system. YORK instruments are used for incoming screening, purifier breakthrough alarms, CDA and house nitrogen.
Why is moisture the hardest impurity in UHP gas?
Water adsorbs on the inside of tubes and components and is released slowly, so it persists long after the source is removed.
What does −110 °C frost point correspond to?
About 1.6 ppbv of water at atmospheric pressure (calculated).