Compressed air and industrial gases: where to measure dew point, O₂ and CO₂
Follow the air from the compressor to the dryer, the breathing-air fill panel, the nitrogen generator and the medical air plant, then the cylinder-filling and beverage CO₂ lines. Each numbered point shows the limit and the analyzer that fits.
Tap a numbered point. Swipe the diagram sideways on a phone.
⤓ Download the 2-page PDF application note
How the process works
Most plants make their own compressed air and many make their own nitrogen. Gas companies fill cylinders, and drink producers use CO₂ from bulk tanks. In each case a quality limit is written into a standard, and an analyzer proves the gas meets it.
- Compression. The compressor, aftercooler and receiver deliver air saturated with water, plus oil and particles.
- Drying. A refrigerated dryer reaches a pressure dew point of about +3 °C (ISO 8573-1 Class 4). A desiccant dryer reaches −40 °C or −70 °C (Class 2 or 1).
- Distribution. Dry air feeds plant and instrument air, and the special users downstream.
- Breathing air. A purifier removes water, oil, CO₂ and CO before high-pressure cylinders are filled.
- Nitrogen generation. Membrane or PSA units separate nitrogen from compressed air; residual oxygen measures their purity.
- Medical air. A dedicated plant purifies air to the pharmacopoeia monograph.
- Cylinder filling and beverage CO₂. Liquid gases are vaporized and filled into cylinders, or fed to a beverage filler, after a final purity check.
Measurement points at a glance
| # | Point | Measures | Typical value / limit | Recommended solution |
|---|---|---|---|---|
| 1 | Desiccant dryer outlet | Pressure dew point | ISO 8573-1 water classes: Class 1 ≤ −70 °C, Class 2 ≤ −40 °C, Class 3 ≤ −20 °C | DPT810, DPT830 |
| 2 | Refrigerated dryer outlet | Pressure dew point | ISO 8573-1: Class 4 ≤ +3 °C, Class 5 ≤ +7 °C, Class 6 ≤ +10 °C | DM9200 |
| 3 | Distribution header / point of use | Pressure dew point (audit) | The class specified for each user, checked at the point of use | DPT-600 Plus, DM9600P |
| 4 | Distribution header / point of use | Oil and particles | ISO 8573-1 oil classes: Class 1 ≤ 0.01, Class 2 ≤ 0.1, Class 3 ≤ 1, Class 4 ≤ 5 mg/m³ | Integrated system: oil-vapour monitor (PID) and laser particle counter |
| 5 | Breathing-air cylinder fill panel | Water content | ≤ 50 mg/m³ (≈ 67 ppmv) for 200 bar fills; ≤ 30 mg/m³ (≈ 40 ppmv) for 300 bar fills (Norwegian regulation) | DPT-600 Plus, DPT810 |
| 6 | Breathing-air cylinder fill panel | O₂, CO₂ and CO | O₂ 21 ± 0.5 %; CO₂ ≤ 500 ppm; CO ≤ 10 ppm; oil ≤ 1 mg/m³ (Norwegian regulation) | POA300, PGA520; Integrated system: electrochemical CO analyzer |
| 7 | Nitrogen generator outlet | Residual oxygen | Membrane units leave percent-level O₂; PSA units reach ppm level. The limit is your inerting specification | POA300, PGA530, POA3500, POA200, PGA500 |
| 8 | Medical air plant outlet | Water | ≤ 67 ppm (≈ −46 °C dew point at atmospheric pressure) in pharmacopoeia monographs | DPT810, DM9600 |
| 9 | Medical air plant outlet | O₂, CO₂ and trace contaminants | O₂ 19.5–23.5 %; CO₂ ≤ 500 ppm; CO ≤ 5 ppm; SO₂ ≤ 1 ppm; NO + NO₂ ≤ 2 ppm; oil ≤ 0.1 ppm | POA3500, POA300, PGA520; Integrated system: CO, NOx, SO₂ and oil analyzers |
| 10 | Cylinder filling manifold | Water in N₂, Ar, O₂ | GB/T 8979-2025 nitrogen: < 15 ppm (pure), < 3 ppm (high purity), < 0.5 ppm (ultrapure) | DPT830, DM9900 |
| 11 | Cylinder filling manifold | Trace O₂ in N₂ and Ar; purity of O₂ | GB/T 8979-2025 nitrogen: O₂ < 50 ppm (pure), < 3 ppm (high purity), < 0.1 ppm (ultrapure) | POA200, PGA500, POA3500 |
| 12 | Beverage CO₂ after the vaporizer | Water and oxygen in CO₂ | ISBT guideline: H₂O ≤ 20 ppm v/v (≈ −55 °C frost point at 1 atm); O₂ ≤ 30 ppm v/v | DPT830, DM9600; Integrated system: trace O₂ analyzer qualified for CO₂ service |
Values are typical figures from published specifications and technical literature. Your contract, licensor or plant specification always governs.
Getting reliable readings
- Pressure dew point or atmospheric dew point. ISO 8573-1 classes are pressure dew points. Pharmacopoeia and breathing-air limits are given as water content. Convert before comparing.
- Measure where it matters. A dry dryer outlet does not prove a dry point of use. Audit the far end of the network with a portable instrument.
- Trace levels need clean sampling. Below about 10 ppm water or oxygen, use stainless tubing, metal seals and a good purge. Plastic tubing lets moisture and oxygen in.
- Oxygen service. Analyzers on oxygen product need oxygen-clean wetted parts.
References
- ISO 8573-1:2010 Compressed air: Contaminants and purity classesISO
- Regulations concerning action and limit values, Section 5-5 (breathing air)Norwegian Labour Inspection Authority
- Farmacopeia Brasileira 7th ed., Vol. II: Medical GasesANVISA
- GB/T 8979-2025 Pure nitrogen, high-purity nitrogen and ultrapure nitrogen (table preview)chinesestandard.net
Related
- Dates: storage and packing measurement points (animated)
- Aviation MRO: oxygen and nitrogen check points (animated)
- Air separation units: measurement points (animated)
- All process maps by industry
- Compressed air dew point
- Industrial gas purity
- CO₂ in food, beverage and modified atmosphere packaging
- Dew point to ppmV conversion table
- Green hydrogen and refuelling: measurement points (animated)
- Ammonia, urea and air separation: measurement points (animated)
Frequently asked questions
What dew point does ISO 8573-1 require?
It defines classes rather than one value: Class 1 ≤ −70 °C, Class 2 ≤ −40 °C, Class 3 ≤ −20 °C, Class 4 ≤ +3 °C, Class 5 ≤ +7 °C and Class 6 ≤ +10 °C pressure dew point. The user specifies the class.
How dry must breathing air be?
The Norwegian regulation, for example, allows at most 50 mg/m³ of water for 200 bar fills and 30 mg/m³ for 300 bar fills, about 67 and 40 ppmv.
How is a nitrogen generator's purity checked?
By measuring the residual oxygen at its outlet: a percent-range analyzer for membrane units and a trace-oxygen analyzer for high-purity PSA units.
What moisture limit applies to medical air?
The pharmacopoeia monographs set at most 67 ppm water, about −46 °C dew point at atmospheric pressure.
Planning gas quality monitoring?
Tell us the gas, the standard you must meet and the points you want to measure, and we will propose the instruments.