Compressed air and industrial gases: where to measure dew point, O₂ and CO₂

Follow the air from the compressor to the dryer, the breathing-air fill panel, the nitrogen generator and the medical air plant, then the cylinder-filling and beverage CO₂ lines. Each numbered point shows the limit and the analyzer that fits.

COMPRESSED AIR SYSTEMTO PLANT / INSTRUMENT AIRN₂GAS SUPPLY · CYLINDER FILLING · BEVERAGE CO₂CYLINDERSAIR COMPRESSORAFTERCOOLERRECEIVERDESICCANT DRYERREFRIGERATED DRYERBREATHING-AIRPURIFIERFILL PANELN₂GENERATORBUFFERTANKMEDICAL AIRPLANTLIQUIDN₂ / Ar / O₂VAPORIZERCYLINDERFILLINGLIQUID CO₂VAPORIZERBEVERAGEFILLER1H₂O2H₂O3H₂O4OIL5H₂O6O₂·CO₂7O₂8H₂O9O₂·CO₂10H₂O11O₂12H₂O·O₂
YORK instrumentIntegrated system (supplied through YORK)

Tap a numbered point. Swipe the diagram sideways on a phone.

Request a quote for this point →
Auto tour
Project list 0 →

⤓ Download the 2-page PDF application note

How the process works

Most plants make their own compressed air and many make their own nitrogen. Gas companies fill cylinders, and drink producers use CO₂ from bulk tanks. In each case a quality limit is written into a standard, and an analyzer proves the gas meets it.

  1. Compression. The compressor, aftercooler and receiver deliver air saturated with water, plus oil and particles.
  2. Drying. A refrigerated dryer reaches a pressure dew point of about +3 °C (ISO 8573-1 Class 4). A desiccant dryer reaches −40 °C or −70 °C (Class 2 or 1).
  3. Distribution. Dry air feeds plant and instrument air, and the special users downstream.
  4. Breathing air. A purifier removes water, oil, CO₂ and CO before high-pressure cylinders are filled.
  5. Nitrogen generation. Membrane or PSA units separate nitrogen from compressed air; residual oxygen measures their purity.
  6. Medical air. A dedicated plant purifies air to the pharmacopoeia monograph.
  7. Cylinder filling and beverage CO₂. Liquid gases are vaporized and filled into cylinders, or fed to a beverage filler, after a final purity check.

Measurement points at a glance

#PointMeasuresTypical value / limitRecommended solution
1Desiccant dryer outletPressure dew pointISO 8573-1 water classes: Class 1 ≤ −70 °C, Class 2 ≤ −40 °C, Class 3 ≤ −20 °CDPT810, DPT830
2Refrigerated dryer outletPressure dew pointISO 8573-1: Class 4 ≤ +3 °C, Class 5 ≤ +7 °C, Class 6 ≤ +10 °CDM9200
3Distribution header / point of usePressure dew point (audit)The class specified for each user, checked at the point of useDPT-600 Plus, DM9600P
4Distribution header / point of useOil and particlesISO 8573-1 oil classes: Class 1 ≤ 0.01, Class 2 ≤ 0.1, Class 3 ≤ 1, Class 4 ≤ 5 mg/m³Integrated system: oil-vapour monitor (PID) and laser particle counter
5Breathing-air cylinder fill panelWater content≤ 50 mg/m³ (≈ 67 ppmv) for 200 bar fills; ≤ 30 mg/m³ (≈ 40 ppmv) for 300 bar fills (Norwegian regulation)DPT-600 Plus, DPT810
6Breathing-air cylinder fill panelO₂, CO₂ and COO₂ 21 ± 0.5 %; CO₂ ≤ 500 ppm; CO ≤ 10 ppm; oil ≤ 1 mg/m³ (Norwegian regulation)POA300, PGA520; Integrated system: electrochemical CO analyzer
7Nitrogen generator outletResidual oxygenMembrane units leave percent-level O₂; PSA units reach ppm level. The limit is your inerting specificationPOA300, PGA530, POA3500, POA200, PGA500
8Medical air plant outletWater≤ 67 ppm (≈ −46 °C dew point at atmospheric pressure) in pharmacopoeia monographsDPT810, DM9600
9Medical air plant outletO₂, CO₂ and trace contaminantsO₂ 19.5–23.5 %; CO₂ ≤ 500 ppm; CO ≤ 5 ppm; SO₂ ≤ 1 ppm; NO + NO₂ ≤ 2 ppm; oil ≤ 0.1 ppmPOA3500, POA300, PGA520; Integrated system: CO, NOx, SO₂ and oil analyzers
10Cylinder filling manifoldWater in N₂, Ar, O₂GB/T 8979-2025 nitrogen: < 15 ppm (pure), < 3 ppm (high purity), < 0.5 ppm (ultrapure)DPT830, DM9900
11Cylinder filling manifoldTrace O₂ in N₂ and Ar; purity of O₂GB/T 8979-2025 nitrogen: O₂ < 50 ppm (pure), < 3 ppm (high purity), < 0.1 ppm (ultrapure)POA200, PGA500, POA3500
12Beverage CO₂ after the vaporizerWater and oxygen in CO₂ISBT guideline: H₂O ≤ 20 ppm v/v (≈ −55 °C frost point at 1 atm); O₂ ≤ 30 ppm v/vDPT830, DM9600; Integrated system: trace O₂ analyzer qualified for CO₂ service

Values are typical figures from published specifications and technical literature. Your contract, licensor or plant specification always governs.

Getting reliable readings

  • Pressure dew point or atmospheric dew point. ISO 8573-1 classes are pressure dew points. Pharmacopoeia and breathing-air limits are given as water content. Convert before comparing.
  • Measure where it matters. A dry dryer outlet does not prove a dry point of use. Audit the far end of the network with a portable instrument.
  • Trace levels need clean sampling. Below about 10 ppm water or oxygen, use stainless tubing, metal seals and a good purge. Plastic tubing lets moisture and oxygen in.
  • Oxygen service. Analyzers on oxygen product need oxygen-clean wetted parts.

Frequently asked questions

What dew point does ISO 8573-1 require?

It defines classes rather than one value: Class 1 ≤ −70 °C, Class 2 ≤ −40 °C, Class 3 ≤ −20 °C, Class 4 ≤ +3 °C, Class 5 ≤ +7 °C and Class 6 ≤ +10 °C pressure dew point. The user specifies the class.

How dry must breathing air be?

The Norwegian regulation, for example, allows at most 50 mg/m³ of water for 200 bar fills and 30 mg/m³ for 300 bar fills, about 67 and 40 ppmv.

How is a nitrogen generator's purity checked?

By measuring the residual oxygen at its outlet: a percent-range analyzer for membrane units and a trace-oxygen analyzer for high-purity PSA units.

What moisture limit applies to medical air?

The pharmacopoeia monographs set at most 67 ppm water, about −46 °C dew point at atmospheric pressure.

Planning gas quality monitoring?

Tell us the gas, the standard you must meet and the points you want to measure, and we will propose the instruments.