O₂ · Oxygen
YORK PGA500 in-line trace oxygen analyzer
The PGA500 is an in-line trace oxygen analyzer for continuous monitoring from 0.01 ppm to 25% O₂. It is installed on nitrogen and argon product lines, nitrogen generators, glove boxes and inert gas supplies in safe areas, with outputs to the control system and alarm relays. For hazardous areas, the PGA500-EX is the explosion-proof version.

| Model | PGA500 |
|---|---|
| Type | In-line trace oxygen analyzer |
| Range | 0.01 ppm to 25% O₂ |
| Principle | Electrochemical |
| Sample handling | Built-in 4-way selection valve |
| Outputs | Analog output, digital output, alarm relay |
| Power | AC or DC supply |
| Not suitable for | CO₂ background and acid gases (H₂S, HCl, SO₂) |
| Hydrogen and hydrocarbons | Usable; sensor life is shorter, about 12 months |
| Hazardous areas | Use the PGA500-EX (Ex db IIC T6 Gb); certificate details are sent with quotations |
| Lead time | 6 to 8 weeks |
| Warranty | 12 months from shipment |
| Regional contact | Dubai, UAE — covers the GCC |
Product catalog (PDF) · certificate copies are sent with quotations.
Where it is installed
| Location | Why oxygen is monitored |
|---|---|
| Air separation unit product lines | ppm O₂ in nitrogen and argon product; see air separation measurement points |
| Nitrogen generators | Product purity with alarm when O₂ rises |
| Glove boxes and inert enclosures | Continuous O₂ in the inert atmosphere; see glove box measurement points |
| Blanketing and inerting | Oxygen in the blanket gas of tanks and reactors; see process oxygen and inerting |
Installation notes
- Use stainless steel sample lines and leak-tight fittings; at ppm levels any air leak shows in the reading.
- Keep a continuous sample flow so the line does not need to purge again after each stop.
- Do not install in CO₂ or acid gas service; use a paramagnetic analyzer for gas containing CO₂.
- In classified areas, use the PGA500-EX or install the PGA500 in a safe area or analyzer shelter.
PGA500 or another YORK oxygen analyzer?
| If you need… | Choose |
|---|---|
| Continuous trace O₂ in a safe area | PGA500 |
| Continuous trace O₂ in a hazardous area | PGA500-EX |
| Continuous percent O₂ | PGA530 |
| Portable trace O₂ checks | POA200 |
Ordering in the UAE and GCC
Send your enquiry to our Dubai team with:
- the gas and where it is measured;
- the expected oxygen range;
- whether the gas contains CO₂, acid gases (H₂S, HCl, SO₂), hydrogen or hydrocarbons;
- whether the measurement point is in a hazardous area;
- quantity.
We reply with a quotation for the PGA500 or PGA500-EX. Instruments are shipped from the factory with export documents, 6 to 8 weeks from order confirmation. Electrochemical cells are consumables; in hydrogen and hydrocarbons expect to replace the cell about every 12 months.
Questions about the PGA500
What is the range of the PGA500?
0.01 ppm to 25% O₂, electrochemical.
What outputs does the PGA500 have?
Analog output, digital output and alarm relay, with AC or DC power supply.
Is there an explosion-proof version?
Yes, the PGA500-EX, marked Ex db IIC T6 Gb. Certificate details are sent with quotations.
Can the PGA500 measure oxygen in CO₂ or sour gas?
No. CO₂ and acid gases such as H₂S, HCl and SO₂ shorten the cell life and affect the reading. Use a paramagnetic analyzer for gas containing CO₂.
How do I get a quotation in the UAE?
Email dubai@yorkinstrument.com or WhatsApp +971 55 137 4866 with the gas, oxygen range, background components, area classification and quantity.