Green hydrogen and refuelling: where to measure O₂ and moisture
Follow the hydrogen from the electrolyser through the deoxo reactor and dryer to the refuelling dispenser. Each numbered point shows the limit, why it matters and the analyzer that fits.
Tap a numbered point. Swipe the diagram sideways on a phone.
⤓ Download the 2-page PDF application note
How the process works
An electrolyser splits water into hydrogen and oxygen. The raw hydrogen is wet and carries some oxygen, so it is purified before compression. Fuel-cell vehicles need hydrogen to ISO 14687 Grade D, with impurity limits in µmol/mol.
- Electrolysis. The stack produces hydrogen on one side and oxygen on the other. Gas-liquid separators return the electrolyte or water.
- Deoxo. A catalytic reactor turns the residual oxygen in the hydrogen into water.
- Drying. A temperature-swing adsorption (TSA) dryer removes the water, down to a few ppm.
- Compression and storage. Compressors raise the pressure for high-pressure storage.
- Dispensing. The dispenser fills the vehicle; the hydrogen at the nozzle must meet ISO 14687 Grade D.
Measurement points at a glance
| # | Point | Measures | Typical value / limit | Recommended solution |
|---|---|---|---|---|
| 1 | Raw hydrogen before the deoxo | Oxygen in hydrogen (%) | 0.15–0.3 mol % O₂ in raw hydrogen from an alkaline electrolyser (design study) | PGA500-EX |
| 2 | Oxygen side of the electrolyser | Hydrogen in oxygen | Alarm and trip levels are set by the electrolyser safety concept | Integrated system: thermal-conductivity H₂-in-O₂ analyzer |
| 3 | After deoxo and dryer | Trace oxygen | < 5 ppm (design target in a purification-train study) | PGA500-EX |
| 4 | After deoxo and dryer | Trace water | < 5 ppm (design target in a purification-train study) | DPT990-EX |
| 5 | Dispenser (ISO 14687 Grade D) | Water | ≤ 5 µmol/mol (≈ −65 °C frost point at 1 atm) | DPT990-EX, DPT-600 Plus-EX |
| 6 | Dispenser (ISO 14687 Grade D) | Oxygen | ≤ 5 µmol/mol | PGA500-EX |
| 7 | Dispenser (ISO 14687 Grade D) | Carbon dioxide | ≤ 2 µmol/mol | Integrated system: trace CO₂ by gas chromatography or laser spectroscopy |
| 8 | Dispenser (ISO 14687 Grade D) | Other impurities and hydrogen index | CO ≤ 0.2; total sulfur ≤ 0.004; formaldehyde ≤ 0.2; NH₃ ≤ 0.1 µmol/mol; hydrogen index ≥ 99.97 % | Integrated system: gas chromatography with several detectors, cavity ring-down or FTIR spectroscopy |
Values are typical figures from published specifications and technical literature. Your contract, licensor or plant specification always governs.
Getting reliable readings
- Hazardous area. Electrolyser and refuelling sites are classified areas; use explosion-proof analyzers or a certified analyzer shelter.
- Sample handling. Hydrogen at the dispenser is at very high pressure. Reduce the pressure in a dedicated sampling system and vent the sample safely.
- Online and laboratory. Water and oxygen can be monitored online; the full ISO 14687 impurity list is normally analysed in the laboratory.
- Units. ISO 14687 limits are in µmol/mol, which equals ppm by volume.
References
- Hydrogen Fuel Regulations (Sec. 4181)California Department of Food & Agriculture
- MetroHyVe / HYDRAITE report on ISO/TC 197 hydrogen qualitySINTEF
- Spatolisano & Pellegrini, A technical analysis of the H₂ purification trains downstream of alkaline electrolyzers, Energies (2025)Politecnico di Milano
Related
- Saudi green hydrogen and ammonia: gas analysis guide
- All process maps by industry
- Industrial gas purity
- Explosion-proof analyzers
- How to choose an oxygen analyzer
- Dew point to ppmV conversion table
- Compressed air and industrial gases: measurement points (animated)
- Ammonia, urea and air separation: measurement points (animated)
Frequently asked questions
What are the ISO 14687 Grade D limits for water and oxygen?
Both are at most 5 µmol/mol. CO₂ is limited to 2 µmol/mol, CO to 0.2 µmol/mol and total sulfur to 0.004 µmol/mol, with a hydrogen index of at least 99.97 %.
Why measure oxygen in electrolytic hydrogen?
Raw hydrogen from an alkaline electrolyser can carry about 0.15–0.3 mol % oxygen. The measurement controls the deoxo reactor and detects crossover, which is a safety issue.
What dew point is 5 ppm of water?
About −65 °C frost point at atmospheric pressure.