Semiconductor and electronics: high-purity gases

Trace moisture and trace oxygen measurement in high-purity nitrogen, argon, hydrogen and other process gases for electronics and semiconductor facilities.

Why it matters

Electronics, semiconductor and solar facilities distribute high-purity nitrogen, argon, hydrogen and other process gases, where moisture and oxygen are critical impurities.

Measurements are made at the gas supply, after purifiers and at points of use to confirm specification and to catch contamination from leaks or maintenance. Very low moisture levels call for trace moisture analyzers and, for reference work, chilled mirror hygrometers with VCR fittings.

Where the demand is in the Gulf

The Gulf's semiconductor push so far centres on chip design. Saudi Arabia's National Semiconductor Hub, for example, was launched in 2024 with a SAR 1 billion fund. Gas measurement demand today sits mainly in electronics assembly, solar and LED production, data-centre and telecom hardware, and the specialty gas suppliers that serve them. The same measurements apply as these plants grow: oxygen in process nitrogen, moisture in compressed air and gases, and screening of incoming high-purity gas.

Semiconductor gas process flow: bulk liquid gas, vaporizer, incoming QC, purifier, valve manifold box and process tool, with hydrogen tube trailer, CDA dryer and house nitrogen generator; measurement points 1 to 6 marked
Process flow and measurement points: 1 incoming gas check and 2 purifier outlet (moisture and oxygen screening), 3 bulk line and 4 point of use (ppb level, integrated system), 5 CDA dryer outlet (dew point), 6 house nitrogen (oxygen). Soldering ovens are not shown. Open the animated map for the details of each point.

What YORK instruments cover, and what they don't

PointTypical levelSuitable instrument
Nitrogen reflow and wave soldering ovensResidual O₂ commonly about 100–1,000 ppm, set by the solder processPGA500 in-line, POA200 for audits
House nitrogen generator outletSet by the plant specificationPGA500, POA200
Clean dry air (CDA) after the dryerPressure dew point, often −40 °C to −70 °CDPT830, DPT810
Incoming bulk gas screening, purifier breakthrough alarmppm level before the purifier; any rise after itDPT830 (to −110 °C frost point), POA200 (from 0.01 ppm O₂)
Ultra-high-purity gas after the purifier and at the toolSub-ppb, with targets below 100 pptAPIMS, CRDS or specialised trace GC, supplied through YORK as an integrated system

For scale: −110 °C frost point is about 1.6 ppb of water by volume at atmospheric pressure, and −76 °C is about 1 ppm. The dew point calculator converts other values.

Electronics assembly: oxygen in soldering nitrogen

Reflow and wave soldering in nitrogen reduce oxidation of the solder and the board, which improves wetting and joint quality. The oxygen level in the oven shows whether the nitrogen is doing its job: too high and the benefit is lost, too low and nitrogen is being wasted. An in-line analyzer with a sample point in the oven lets the line hold its target and alarm on a door left open or a supply problem. A portable analyzer checks several ovens and the nitrogen generator on a round. Fit a filter on the sample line to keep flux residues out of the analyzer.

Sampling at very low levels

  • Use electropolished stainless steel with face-seal (VCR-type) fittings and metal diaphragm valves. The DM9900 reference hygrometer is available with VCR fittings.
  • Avoid polymer parts in the sample path. PTFE and elastomers release moisture for a long time.
  • Expect long dry-down after maintenance. Water adsorbs on tube walls and comes off slowly, so a reading can take hours to reach its true value.
  • Keep a continuous purge flow and vent the analyzer outlet through enough tubing that air cannot diffuse back.

Questions we are asked

Can YORK analyzers certify semiconductor-grade gas?

Not on their own. Sub-ppb and ppt certification needs APIMS, CRDS or specialised trace GC, which YORK can supply as an integrated system. YORK instruments are used for incoming screening, purifier breakthrough alarms, CDA, house nitrogen and soldering ovens.

Which oxygen analyzer suits a reflow oven?

The PGA500 in-line analyzer covers 0.01 ppm to 25% O₂, which spans typical oven setpoints and the air-ingress alarm. The POA200 portable analyzer does the same for audits.

What dew point does clean dry air need?

Fabs and electronics plants set their own specification, often −40 °C to −70 °C pressure dew point. The compressed air page explains pressure versus atmospheric dew point.

Suggested YORK instruments

Discuss your application

Tell us the gas, pressure, sample point and the limit you need to meet, and we will propose instruments and a sample system.