العربية
  1. Home
  2. Products
  3. Chilled mirror hygrometers
  4. DM9700

H₂O · Chilled mirror

YORK DM9700 rack-mount chilled mirror hygrometer

The DM9700 is a rack-mount chilled mirror hygrometer for continuous measurement in laboratories and quality control rooms, from −70 °C frost point to +20 °C dew point. It is used to monitor moisture in nitrogen, argon and oxygen product, and as a working standard on dew point calibration benches, with outputs to data systems.

YORK DM9700 – Rack-mount chilled mirror hygrometer
ModelDM9700
TypeRack-mount chilled mirror hygrometer
Range−70 °C frost point to +20 °C dew point
PrincipleChilled mirror, air cooled
Built inPressure sensor, electronic flow meter
Outputs and dataThree analog outputs, alarm output, SD card logging, USB-C and RS485 (Modbus RTU)
Power80–264 VAC
UseNon-flammable gases in safe areas; sample pressure up to 4 barg
Lead time6 to 8 weeks
Warranty12 months from shipment
Regional contactDubai, UAE — covers the GCC

Product catalog (PDF) · certificate copies are sent with quotations.

Where it is used

UserWhat it measures
Industrial gas QC laboratoriesMoisture in nitrogen, argon and oxygen product; see industrial gas purity
Calibration laboratoriesWorking standard alongside a low humidity generator; see calibration laboratories
Electronics and battery plantsMoisture in nitrogen and dry air supplies, measured in the QC room
Compressed air referenceReference dew point for instrument air in a safe area

Installation notes

  • Install in a rack in a safe area and bring the sample to it, reduced to 4 barg or less.
  • Use electropolished stainless steel lines and keep a continuous sample flow.
  • Connect the analog outputs or Modbus RTU to the data system and set the alarm for the specification limit.
  • YORK chilled mirror hygrometers are low-pressure instruments for non-flammable gases in safe areas; they are not explosion-proof and are not intended for natural gas, hydrogen or other flammable gases.

DM9700 or another YORK instrument?

If you need…Choose
Portable checks to −60 °C frost pointDM9600P
Portable checks to −70 °C frost pointDM9600PL
Rack-mount to −80 °C frost point, VCR fittingsDM9800
Laboratory reference to −90 °C frost pointDM9900
Field checks of flammable gases or in hazardous areasA metal-oxide instrument: DPT-600 Plus-EX or DPT990-EX

Ordering in the UAE and GCC

Send your enquiry to our Dubai team with:

  • the gas and the dew point range;
  • outputs needed (analog, Modbus RTU);
  • quantity.

We reply with a quotation for the DM9700. Instruments are shipped from the factory with export documents, 6 to 8 weeks from order confirmation. The DM9700 runs on 80–264 VAC.

See all dew point meters and analyzers available in the UAE.

Questions about the DM9700

What is the range of the DM9700?

−70 °C frost point to +20 °C dew point.

What outputs does the DM9700 have?

Three analog outputs, an alarm output, SD card logging, USB-C and RS485 (Modbus RTU).

What is the difference between the DM9700 and the DM9800?

The DM9800 reaches −80 °C frost point with a refrigeration system and VCR fittings; the DM9700 is air cooled and reaches −70 °C frost point.

Can it be used for natural gas or other flammable gases?

No. YORK chilled mirror hygrometers are low-pressure instruments (up to 4 barg) and are not explosion-proof; they are for non-flammable gases in safe areas. For natural gas, see the DPT990-EX.

How do I get a quotation in the UAE?

Email dubai@yorkinstrument.com or WhatsApp +971 55 137 4866 with the gas, dew point range, outputs and quantity.