Aviation MRO: where to check oxygen and nitrogen
Follow the oxygen from the cylinder bank to the aircraft, the nitrogen from the generator to the tyres, and the air in the hangar. Each numbered point shows what is checked, the typical limit, why it matters and the instrument that fits.
Tap a numbered point. Swipe the diagram sideways on a phone.
How the base uses oxygen and nitrogen
Airlines and maintenance providers in the Gulf service large fleets at their home bases. Oxygen and nitrogen are checked at many small points across the base, so portable analyzers are as important as fixed ones.
- Oxygen. Aviator's breathing oxygen is stored in a cylinder bank and boosted into servicing carts, which refill the crew and passenger oxygen systems.
- Nitrogen. An on-site generator or nitrogen cylinders supply dry nitrogen for tyres, landing gear struts and accumulators.
- Fuel tank inerting. On many transport aircraft an air separation module makes nitrogen-enriched air that keeps the fuel tank ullage below the flammable oxygen level.
- Shop and breathing air. Compressors and dryers supply the workshops; the paint hangar takes breathing air for supplied-air respirators.
Check points at a glance
| # | Point | Checks | Typical limit | Recommended solution |
|---|---|---|---|---|
| 1 | Oxygen cylinder bank | Oxygen purity (%) | Aviator's breathing oxygen, Type I gas (MIL-PRF-27210): at least 99.5 % O₂ | POA3500, POA300 |
| 2 | Oxygen cylinder bank | Moisture in breathing oxygen | MIL-PRF-27210 Type I: no more than 7 ppm water vapour (dew point −63.3 °C) | DPT-600 Plus, DPT830 |
| 3 | Oxygen servicing cart | Purity and moisture at the point of delivery | The same limits apply at the point where the oxygen enters the aircraft | POA300, DPT-600 Plus |
| 4 | Nitrogen for tyre inflation | Oxygen in tyre nitrogen | FAA AC 20-97B: inflate with dry nitrogen so that the tyre contains no more than 5 % oxygen by volume | PGA530, POA300 |
| 5 | Fuel tank inerting system | Oxygen in nitrogen-enriched air (NEA) | Fuel tank inerting is based on keeping the ullage oxygen at or below about 12 % | POA300, PGA530 |
| 6 | Paint hangar breathing air | Oxygen in breathing air | EN 12021: oxygen 21 ± 1 %; also CO ≤ 5 ppm and CO₂ ≤ 500 ppm | POA300, PGA530 Integrated system: CO and CO₂ monitor |
| 7 | Shop compressed air | Pressure dew point | The ISO 8573-1 class the workshop specifies, for example Class 2 (≤ −40 °C) or Class 4 (≤ +3 °C) | DPT810, DPT-600 Plus |
Values are taken from published specifications and guidance. The aircraft maintenance manual and the operator's approved procedures always govern.
Getting reliable readings
- Check at the point of use. Measure at the cart or the panel that feeds the aircraft, not only at the bulk supply.
- Use portable instruments. Portable oxygen and dew point meters cover many carts, hangars and aircraft.
- Oxygen service. Use oxygen-clean sample lines on aviator's oxygen.
- Follow the manuals. Aircraft maintenance manuals and the operator's procedures set the actual limits and test points.
References
- MIL-PRF-27210: Oxygen, aviator's breathing, liquid and gas (requirements)U.S. Department of Defense specification (summary)
- AC 20-97B: Aircraft tire maintenance and operational practicesU.S. Federal Aviation Administration
- Inerting system (fuel tank inerting, 12 % oxygen basis)Wikipedia
- EN 12021:2014 Respiratory equipment: Compressed gases for breathing apparatusCEN (standard listing)
Frequently asked questions
What moisture limit applies to aviator's breathing oxygen?
MIL-PRF-27210 Type I gaseous oxygen allows no more than 7 ppm of water vapour, a dew point of −63.3 °C, with at least 99.5 % oxygen.
How much oxygen is allowed in aircraft tyre nitrogen?
FAA AC 20-97B says to inflate with dry nitrogen so that the tyre contains no more than 5 % oxygen by volume.
Can one portable analyzer cover several checks at a base?
Yes. A portable oxygen analyzer covers oxygen carts, tyre nitrogen and inerting checks in turn; a portable dew point meter covers oxygen and shop air moisture.
Equipping a maintenance base?