Float glass: where to measure moisture, O₂ and H₂ in the tin bath

Follow the glass from the melting furnace over the tin bath to the lehr, and the protective gas from the N₂ and H₂ supply to the bath. Each point shows what is measured and which analyzer fits.

NG+AIRFLUE GASGLASS RIBBONPROTECTIVE ATMOSPHEREMELTING FURNACETIN BATH · N₂ + H₂ ATMOSPHEREANNEALING LEHRN₂ SUPPLY(PSA / ASU)H₂ SUPPLY(ELECTROLYSER)MIXINGSTATION1O₂2H₂O·O₂3H₂O·O₂4H₂ %5O₂·H₂O6O₂ (Sn)
YORK instrumentIntegrated system (supplied through YORK)

Tap a numbered point. Swipe the diagram sideways on a phone.

Request a quote for this point →
Auto tour
Project list 0 →

⤓ Download the 2-page PDF application note

How the process works

Molten glass floats on a bath of molten tin under a nitrogen–hydrogen atmosphere. Any oxygen or water that reaches the tin forms tin oxide and glass defects, so the protective gas and its supply are watched closely.

  1. Melting. A regenerative furnace melts the batch with natural gas and air.
  2. Forming on tin. The glass ribbon spreads and flattens on molten tin under a slight positive pressure of protective gas.
  3. Protective atmosphere. A mixing station blends dry nitrogen with hydrogen, which scavenges oxygen in the bath.
  4. Annealing. The ribbon cools slowly in the lehr to relieve stress.

Measurement points at a glance

#PointMeasuresTypical value / limitRecommended solution
1Melting furnace flue gasCombustion oxygenSet by the furnace combustion designPOA3500; Integrated system: in-situ zirconia oxygen probe
2Nitrogen supply to the mixing stationDew point and trace oxygenVery dry, low-ppm oxygen nitrogen; limits set by the plant specificationDPT830, POA200, PGA500
3Hydrogen supply to the mixing stationDew point and trace oxygenHigh-purity hydrogen; limits set by the plant specificationDPT990-EX, PGA500-EX
4Mixed protective gas to the bathHydrogen contentNitrogen with a few percent hydrogen, typically up to about 10 %Integrated system: thermal-conductivity hydrogen analyzer
5Tin bath atmosphere (several zones)Oxygen partial pressure, dew point, H₂ %Monitored by zone; a rising inlet dew point flags air ingressIntegrated system: heated extractive zirconia and thermal-conductivity analyzer system
6Molten tinDissolved oxygenPatent trial: reduced from 40 ppm to 2 ppmIntegrated system: in-melt electrochemical oxygen probe

Values are typical figures from published specifications and technical literature. Your contract, licensor or plant specification always governs.

Practical notes

  • Check the supply first. Measuring dew point and oxygen on each supply gas separates a supply problem from an air leak into the bath.
  • Air ingress. A rise in bath dew point or oxygen partial pressure usually means air is leaking in at seals or the exit end.
  • Hydrogen safety. The H₂ line and mixing station are hazardous areas: use explosion-proof analyzers there.

Frequently asked questions

Why does a float glass tin bath need a protective atmosphere?

Oxygen and water oxidise the molten tin. Tin oxide causes defects on the glass and condenses on the bath roof. A nitrogen–hydrogen atmosphere keeps oxygen out and scavenges what gets in.

Which points can YORK instruments cover?

Dew point and trace oxygen in the nitrogen and hydrogen supply. Bath atmosphere, hydrogen content, dissolved oxygen in tin and furnace combustion use integrated systems that YORK supplies.

How is air ingress into the bath detected?

By a rise in dew point or oxygen partial pressure measured at several zones of the bath.