Float glass: where to measure moisture, O₂ and H₂ in the tin bath
Follow the glass from the melting furnace over the tin bath to the lehr, and the protective gas from the N₂ and H₂ supply to the bath. Each point shows what is measured and which analyzer fits.
Tap a numbered point. Swipe the diagram sideways on a phone.
⤓ Download the 2-page PDF application note
How the process works
Molten glass floats on a bath of molten tin under a nitrogen–hydrogen atmosphere. Any oxygen or water that reaches the tin forms tin oxide and glass defects, so the protective gas and its supply are watched closely.
- Melting. A regenerative furnace melts the batch with natural gas and air.
- Forming on tin. The glass ribbon spreads and flattens on molten tin under a slight positive pressure of protective gas.
- Protective atmosphere. A mixing station blends dry nitrogen with hydrogen, which scavenges oxygen in the bath.
- Annealing. The ribbon cools slowly in the lehr to relieve stress.
Measurement points at a glance
| # | Point | Measures | Typical value / limit | Recommended solution |
|---|---|---|---|---|
| 1 | Melting furnace flue gas | Combustion oxygen | Set by the furnace combustion design | POA3500; Integrated system: in-situ zirconia oxygen probe |
| 2 | Nitrogen supply to the mixing station | Dew point and trace oxygen | Very dry, low-ppm oxygen nitrogen; limits set by the plant specification | DPT830, POA200, PGA500 |
| 3 | Hydrogen supply to the mixing station | Dew point and trace oxygen | High-purity hydrogen; limits set by the plant specification | DPT990-EX, PGA500-EX |
| 4 | Mixed protective gas to the bath | Hydrogen content | Nitrogen with a few percent hydrogen, typically up to about 10 % | Integrated system: thermal-conductivity hydrogen analyzer |
| 5 | Tin bath atmosphere (several zones) | Oxygen partial pressure, dew point, H₂ % | Monitored by zone; a rising inlet dew point flags air ingress | Integrated system: heated extractive zirconia and thermal-conductivity analyzer system |
| 6 | Molten tin | Dissolved oxygen | Patent trial: reduced from 40 ppm to 2 ppm | Integrated system: in-melt electrochemical oxygen probe |
Values are typical figures from published specifications and technical literature. Your contract, licensor or plant specification always governs.
Practical notes
- Check the supply first. Measuring dew point and oxygen on each supply gas separates a supply problem from an air leak into the bath.
- Air ingress. A rise in bath dew point or oxygen partial pressure usually means air is leaking in at seals or the exit end.
- Hydrogen safety. The H₂ line and mixing station are hazardous areas: use explosion-proof analyzers there.
References
Frequently asked questions
Why does a float glass tin bath need a protective atmosphere?
Oxygen and water oxidise the molten tin. Tin oxide causes defects on the glass and condenses on the bath roof. A nitrogen–hydrogen atmosphere keeps oxygen out and scavenges what gets in.
Which points can YORK instruments cover?
Dew point and trace oxygen in the nitrogen and hydrogen supply. Bath atmosphere, hydrogen content, dissolved oxygen in tin and furnace combustion use integrated systems that YORK supplies.
How is air ingress into the bath detected?
By a rise in dew point or oxygen partial pressure measured at several zones of the bath.