Heat treatment atmospheres: where to measure dew point, O₂ and CO₂

Follow the atmosphere from the gas generators and the nitrogen–hydrogen supply into each furnace. Each numbered point shows what is measured, why it matters and the instrument that fits.

NATURAL GAS + AIRNATURAL GAS + AIRENDO GENERATORCARBURIZING FURNACEOIL QUENCHEXO GENERATORANNEALING(EXO GAS)N₂ / H₂ SUPPLYBRIGHT ANNEALING (STAINLESS)SINTERINGALUMINIUM CAB BRAZING1H₂O2CO₂3C%4H₂O5CO₂6H₂O7O₂8H₂O9O₂10H₂O
YORK instrumentIntegrated system (supplied through YORK)

Tap a numbered point. Swipe the diagram sideways on a phone.

Request a quote for this point →
Auto tour
Project list 0 →

How the process works

Furnace atmospheres protect the parts from oxidation and, in carburizing, add carbon to the surface. Their quality comes down to a few gases: water vapour, oxygen, CO₂, CO and methane.

  1. Endothermic generator. Natural gas reacts with a little air over a hot catalyst to give a carrier gas of about 20 % CO, 40 % H₂ and 40 % N₂.
  2. Carburizing. The endothermic gas carries carbon into the steel. The furnace controls the carbon potential, then the parts are quenched.
  3. Exothermic generator. Natural gas burns with more air to give a cheaper, more oxidizing gas for annealing and brazing of less sensitive metals.
  4. Nitrogen–hydrogen atmospheres. Bright annealing of stainless steel and sintering need a very dry, oxygen-free atmosphere of nitrogen and hydrogen.
  5. Aluminium brazing. Controlled atmosphere brazing (CAB) runs in nitrogen with flux; oxygen and moisture must stay low for good joints.

Measurement points at a glance

#PointMeasuresTypical value / limitRecommended solution
1Endothermic gas to the furnaceDew pointSet point follows the carbon potential required for the steelDPT990-EX, DPT-600 Plus
2Endothermic gas to the furnaceCO₂, CO and CH₄Nominally 20 % CO, 40 % H₂, 40 % N₂, with 0.25–0.5 % CO₂ and ≤ 0.5 % CH₄Integrated system: three-gas NDIR analyzer (CO / CO₂ / CH₄)
3Carburizing furnace chamberCarbon potential (oxygen probe)Controlled to the carbon level specified for the case depthIntegrated system: in-situ zirconia carbon probe
4Exothermic gas to the annealing furnaceDew pointSet by the generator's gas cooler; check it against the process requirementDPT990-EX, DPT-600 Plus
5Exothermic gas to the annealing furnaceCO₂ (%)Percent level, depending on the air-to-gas ratioPGA520, PGA620
6Bright annealing furnace (stainless steel)Dew point of the N₂–H₂ atmosphereVery dry: typically around −60 °C or lowerDPT990-EX
7Bright annealing furnace (stainless steel)Trace oxygenLow ppmPGA500-EX
8Sintering furnaceDew point of the N₂–H₂ atmosphereDry enough to reduce surface oxides; set per alloyDPT990-EX, DPT830
9Aluminium CAB brazing furnaceTrace oxygen in N₂≤ 40 ppm O₂POA200, PGA500
10Aluminium CAB brazing furnaceDew pointKept dry; agree the limit with the brazing furnace supplierDPT830

Values are typical figures from published specifications and technical literature. Your contract, licensor or plant specification always governs.

Getting reliable readings

  • Soot and tar. Generator gas carries soot: use filters and heated sample lines so nothing condenses before the sensor.
  • Hydrogen. Atmospheres with hydrogen create hazardous areas; use explosion-proof analyzers or certified housings.
  • Measure in the furnace. Air leaks and wet parts add moisture inside the furnace, so the supply gas reading alone can look better than the furnace really is.
  • Cross-check the probe. In carburizing, compare the in-situ carbon probe with an extractive dew point or CO₂ reading.

Frequently asked questions

Why is dew point measured in endothermic gas?

The water vapour content, together with CO₂, follows the carbon potential of the atmosphere. Tracking the dew point shows whether the generator and furnace will carburize correctly.

What is in endothermic gas?

Nominally about 20 % CO, 40 % H₂ and 40 % N₂, with 0.25–0.5 % CO₂ and up to 0.5 % CH₄.

What oxygen level is used for aluminium CAB brazing?

Published work on controlled atmosphere brazing uses a nitrogen atmosphere with no more than 40 ppm oxygen.

Which instruments suit hydrogen furnace atmospheres?

Explosion-proof dew point transmitters and oxygen analyzers, with a chilled-mirror hygrometer as the reference instrument.

Improving furnace atmosphere control?