Carbon capture in the Gulf: CO₂ dehydration and water content measurement

Habshan in Abu Dhabi and the Jubail hub in Saudi Arabia take Gulf carbon capture to industrial scale. Captured CO₂ must be dried before the pipeline, and the dew point proves it.

Gulf CCS projects

Carbon capture in the Gulf is moving from one demonstration plant to industrial scale. Every project compresses and dries the captured CO₂ before it goes down a pipeline, so the water content after dehydration is one of the key quality measurements.

ProjectCapacityStatus
Al Reyadah, Abu Dhabi (CO₂ from Emirates Steel Arkan)Up to 0.8 Mt CO₂/yrOperating since 2016
Habshan CCUS, Abu Dhabi (ADNOC gas processing)1.5 Mt CO₂/yr; takes ADNOC to 2.3 Mt/yrCompletion targeted for 2026
Jubail CCS hub, Saudi Arabia (Aramco 60 %, Linde 20 %, SLB 20 %)Phase 1 up to 9 Mt CO₂/yrPhase 1 construction expected to finish by end of 2027

Sources listed under References. The Jubail hub will take CO₂ from three Aramco gas plants and other industrial sources.

Why the water content matters

Wet CO₂ forms carbonic acid with free water, which corrodes carbon-steel pipelines, and it can form hydrates at pipeline conditions. Glycol contactors or molecular-sieve dryers remove the water; an online dew point analyzer at the dryer outlet confirms the specification and warns of breakthrough.

Measurement points

PointMeasuresTypical value / limitSuggested solution
Dehydration outletWater content500 ppmv design value for EOR pipelines (≈ −27 °C frost point at 1 atm); many storage projects set tighter limitsDPT830, DPT990-EX (hazardous area)
Dryer check and auditsReference dew pointVerifies the online analyzerDM9700, DM9900
Pipeline to EOR / storageCO₂ purity≥ 95 % (design value)PGA520 for process trend; specification checks by GC or a narrow-range analyzer
Pipeline to EOR / storageTrace oxygen10 ppmv design valueIntegrated system: trace O₂ analyzer qualified for CO₂ service
Pipeline to EOR / storageCO, H₂S, N₂ and other impuritiesProject specificationIntegrated system: process gas chromatograph

Getting reliable readings

  • Heat the pressure regulator. CO₂ cools strongly when its pressure drops. Use a heated regulator so the sample does not freeze or condense water before the analyzer.
  • Measure near atmospheric pressure. YORK dew point analyzers accept up to 4 barg and convert the reading to line pressure. They measure in the gas phase only.
  • No electrochemical oxygen cells in CO₂. A CO₂ background shortens their life sharply: use an oxygen analyzer qualified for CO₂ service.
  • Project limits govern. Water and impurity limits are set per pipeline and storage site; the NETL figures are design parameters, not a universal standard.

Frequently asked questions

How much water is allowed in a CO₂ pipeline?

It is set per project. A widely used NETL design value for EOR pipelines is 500 ppmv (about −27 °C frost point at 1 atm); many storage projects specify tighter limits.

Why must captured CO₂ be dried?

Free water and CO₂ form carbonic acid, which corrodes carbon-steel pipe, and water can form hydrates. Dehydration keeps the CO₂ below its water limit along the whole route.

How do you measure dew point in dense-phase CO₂?

Take a sample through a heated pressure regulator, reduce it to near-atmospheric pressure, measure in the gas phase and convert the result to line pressure.

Can an electrochemical oxygen analyzer be used in CO₂?

No. A CO₂ background shortens electrochemical sensor life sharply. Use an oxygen analyzer qualified for CO₂ service.

Measuring water in CO₂?

Send us the pressure, the water limit and the area classification, and our Dubai contact will propose an analyzer and sample system.