Low dew point generators and dew point calibration systems in the UAE

YORK Instrument supplies low humidity and low dew point generators, dry gas generators and complete dew point calibration systems to calibration laboratories, plants and service companies in the UAE and across the GCC. Enquiries are handled by our regional contact in Dubai.

Compare all low humidity and low dew point generators: DC1000, DC2000 and the YKDC220 system.

At a glance

Dry gas generatorDC1000: up to 10 NL/min of dry air below 1 ppmV (−75 °C dew point)
Low humidity generatorDC2000: stability better than ±0.2 °C frost point, four electronic mass flow controllers, three outlets
Complete systemYKDC220: 19-inch rack with DC1000, DC2000 and a chilled mirror reference (DM9700, DM9800 or DM9900)
Reference hygrometersDM9700 to −70 °C, DM9800 to −80 °C, DM9900 to −90 °C frost point
Delivery6 to 8 weeks from order confirmation
Regional contactDubai, UAE · dubai@yorkinstrument.com · +971 55 137 4866

Which calibration equipment do you need?

Your situationSuggested YORK equipmentWhy
Calibration laboratory adding low dew point to its scopeYKDC220 with DM9900 referenceComplete bench: dry gas, stable set points and a chilled mirror reference down to −90 °C frost point
Plant or service company recalibrating its own transmittersDC2000 + DC1000 with a DM9700 or DM9800 referenceStable set points for routine checks without shipping instruments abroad
Field verification at siteDM9600P portable chilled mirrorBattery powered, compares a fixed transmitter with a direct dew point measurement
A very dry gas source only: zero checks, purging, drying down linesDC1000Pressure swing adsorption, up to 10 NL/min below 1 ppmV

How a dew point calibration bench works

The DC1000 supplies dry gas. The DC2000 mixes dry and wet gas with four electronic mass flow controllers to hold a stable set point, and feeds the same gas to a chilled mirror reference and to two instruments under test. The generator makes the set point stable; the chilled mirror reference tells you what that set point is. Traceability therefore comes from the reference hygrometer and its calibration.

For the full step-by-step procedure, read how to calibrate a dew point sensor. To convert between frost point and ppmV, use the dew point calculator.

Typical calibration points

Dew point instruments in gas, air and battery applications are usually checked at a few points across their working range, working from dry to wet. The table gives the water content at each frost point at atmospheric pressure (Sonntag 1990, over ice), so you can match the points to your process specification.

Frost pointWater content at 1 atmTypical use
−80 °C0.54 ppmVTrace moisture transmitters, high-purity gases
−70 °C2.6 ppmVISO 8573-1 class 1 air, battery dry rooms
−60 °C10.7 ppmVIndustrial gases, glove boxes
−40 °C127 ppmVDesiccant-dried instrument air
−20 °C1,019 ppmVMembrane-dried air, general checks

Calibration, traceability and accreditation

Only dew point instruments need to return to the factory for calibration; contact us to arrange factory recalibration. Oxygen analyzers are calibrated by the user with certified calibration gas, following the instruction manual. YORK dew point measurements are traceable to the National Institute of Metrology, China (NIM); the reference standard is a chilled mirror dew point hygrometer and calibration follows JJF 1272-2011. A CNAS-accredited calibration certificate can be issued at extra cost; for the DM9900 reference, the price depends on the lowest calibration point.

Where a project requires calibration accredited by EIAC in the UAE or SAAC in Saudi Arabia, use a local ISO/IEC 17025 laboratory. A laboratory that wants to offer accredited low dew point calibration itself needs a quality system to ISO/IEC 17025 and assessment by EIAC or SAAC.

More on laboratory set-ups: dew point calibration laboratories. All models: moisture calibration systems.

How to buy in the UAE

Send the Dubai regional contact the instruments you calibrate, the dew point range and calibration points, the number of instruments per run, your compressed air supply and whether you plan ISO/IEC 17025 accreditation. Quotations are made directly by our regional team; equipment is shipped from the factory with export documents, 6 to 8 weeks from order confirmation.

For dew point meters, see dew point meters in the UAE. For Saudi Arabia, see analyzers in Saudi Arabia.

Frequently asked questions

Who supplies humidity generators or dew point calibration systems in the UAE?

YORK Instrument supplies the DC2000 low humidity generator, the DC1000 dry gas generator and the YKDC220 dew point calibration system in the UAE and the GCC through its regional contact in Dubai: dubai@yorkinstrument.com, WhatsApp +971 55 137 4866.

What is the difference between a low humidity generator and a dry gas generator?

A dry gas generator such as the DC1000 only makes very dry gas, below 1 ppmV. A low humidity generator such as the DC2000 mixes dry and wet gas to hold stable dew point set points for calibration, with stability better than ±0.2 °C frost point.

How low can the YKDC220 calibrate?

It depends on the reference hygrometer: the DM9700 measures to −70 °C, the DM9800 to −80 °C and the DM9900 to −90 °C frost point.

Does YORK offer dew point calibration services in Dubai?

YORK does not run a calibration laboratory in Dubai, but dew point instruments can be returned to the factory for recalibration, with a CNAS-accredited certificate at extra cost; measurements are traceable to NIM, China. If your project requires EIAC or SAAC accreditation, use a local ISO/IEC 17025 laboratory, or build your own bench with the YKDC220.

How many instruments can be calibrated at once?

The DC2000 has three outlets: one for the reference hygrometer and two for instruments under test.

What are the delivery time and warranty?

Equipment is delivered 6 to 8 weeks after order confirmation. The DC1000 and DC2000 have a 12-month warranty from shipment.

Ask for a quotation

Tell us the instruments you calibrate and the lowest dew point you need, and we will propose a generator or a complete bench.