Medical gases: where to measure moisture, O₂ and CO₂
Follow medical air from the compressors to the wards, and medical oxygen and CO₂ from storage to the pipeline and cylinders. Each point shows the pharmacopoeia limit and the analyzer that fits.
Tap a numbered point. Swipe the diagram sideways on a phone.
⤓ Download the 2-page PDF application note
How the process works
Hospitals make medical air on site and receive oxygen and CO₂ as liquid or produce oxygen with PSA units. Pharmacopoeia monographs set the limits that each gas must meet before it reaches patients.
- Compression. Duty and standby compressors draw in air from a clean intake.
- Drying and filtration. Aftercoolers, desiccant dryers and filters remove water, oil and particles.
- Oxygen supply. Liquid oxygen is vaporised, or PSA units concentrate oxygen from air, and a manifold feeds the pipeline.
- Cylinders. Medical oxygen and CO₂ are filled into cylinders and released after testing.
Measurement points at a glance
| # | Point | Measures | Typical value / limit | Recommended solution |
|---|---|---|---|---|
| 1 | Medical air plant outlet | Water | ≤ 67 ppm (≈ −46 °C dew point at atmospheric pressure) in pharmacopoeia monographs | DPT810, DM9600 |
| 2 | Medical air plant outlet | Oxygen | 19.5–23.5 % | POA3500, POA300 |
| 3 | Medical air plant outlet | Carbon dioxide | ≤ 500 ppm | PGA520 |
| 4 | Medical air plant outlet | CO, SO₂, NO + NO₂, oil | CO ≤ 5 ppm; SO₂ ≤ 1 ppm; NO + NO₂ ≤ 2 ppm; oil ≤ 0.1 ppm | Integrated system: electrochemical or NDIR CO, chemiluminescence NOx and oil-vapour monitoring |
| 5 | Medical oxygen manifold | Oxygen assay | ≥ 99.0 % for medical oxygen | POA3500 |
| 6 | Medical oxygen manifold / cylinder filling | Water and CO₂ | H₂O ≤ 67 ppm; CO₂ ≤ 300 ppm | DPT830, DPT-600 Plus, PGA520 |
| 7 | Medical CO₂ cylinder filling | CO₂ purity and water | ≥ 99.0 %; H₂O ≤ 67 ppm | DPT830; Integrated system: CO₂ assay analyzer (NDIR or GC) for the ≥ 99.0 % purity test |
Values are typical figures from published specifications and technical literature. Your contract, licensor or plant specification always governs.
Practical notes
- Pressure basis. The 67 ppm water limit corresponds to about −46 °C dew point at atmospheric pressure. At line pressure the dew point is higher, so convert before comparing.
- Check the intake. CO₂ and CO at the plant outlet usually point to a poorly placed air intake.
- Standards. Limits follow the pharmacopoeia monographs for medical gases; national hospital standards may add requirements.
References
Frequently asked questions
What is the water limit for medical air?
Pharmacopoeia monographs set water at 67 ppm or less, about −46 °C dew point at atmospheric pressure.
What oxygen content must medical air have?
Between 19.5 % and 23.5 %.
Which analyzers does a medical air plant need?
A dew point analyzer, an oxygen analyzer and a CO₂ analyzer, which YORK supplies, plus CO, SO₂, NOx and oil monitoring as an integrated system.