H₂O · Chilled mirror

YORK DM9600 benchtop chilled mirror hygrometer

The DM9600 is a benchtop chilled mirror hygrometer for laboratories and quality control rooms, from −60 °C frost point to +20 °C dew point. It runs on mains power and has a built-in pressure sensor and electronic flow meter, so samples of compressed air, nitrogen, SF₆ and other non-flammable gases can be checked directly on the bench.

YORK DM9600 – Benchtop chilled mirror hygrometer
ModelDM9600
TypeBenchtop chilled mirror hygrometer
Range−60 °C frost point to +20 °C dew point
PrincipleChilled mirror, air cooled
Built inPressure sensor, electronic flow meter
Power80–264 VAC
UseNon-flammable gases in safe areas; sample pressure up to 4 barg
Lead time6 to 8 weeks
Warranty12 months from shipment
Regional contactDubai, UAE — covers the GCC

Product catalog (PDF) · certificate copies are sent with quotations.

Where it is used

UserWhat it measures
QC laboratoriesMoisture in nitrogen, argon, oxygen and compressed air samples; see industrial gas purity
Power utilitiesSF₆ cylinder and sample checks in the laboratory; see the SF₆ moisture calculator
Instrument workshopsChecking dew point transmitters against a direct measurement

Good practice

  • Bring the sample to the bench at 4 barg or less through stainless steel tubing.
  • Use the built-in flow meter to keep the flow steady, and wait for a stable dew or frost layer before recording.
  • For site work, use the portable DM9600P.
  • YORK chilled mirror hygrometers are low-pressure instruments for non-flammable gases in safe areas; they are not explosion-proof and are not intended for natural gas, hydrogen or other flammable gases.

DM9600 or another YORK chilled mirror?

If you need…Choose
High dew points up to +90 °C, climatic chambers, insertion probeDM9200
Portable checks to −60 °C frost pointDM9600P
Portable checks to −70 °C frost pointDM9600PL
Rack-mount monitoring to −70 or −80 °C frost pointDM9700 or DM9800
Laboratory reference to −90 °C frost pointDM9900
Flammable gases or hazardous areasA metal-oxide instrument: DPT-600 Plus-EX or DPT990-EX

Ordering in the UAE and GCC

Send your enquiry to our Dubai team with:

  • the gases you check;
  • the dew point range;
  • quantity.

We reply with a quotation for the DM9600. Instruments are shipped from the factory with export documents, 6 to 8 weeks from order confirmation. The DM9600 runs on 80–264 VAC.

See all dew point meters and analyzers available in the UAE.

Questions about the DM9600

What is the range of the DM9600?

−60 °C frost point to +20 °C dew point.

What is the difference between the DM9600 and the DM9600P?

Both reach −60 °C frost point. The DM9600 is a mains-powered benchtop instrument; the DM9600P is battery powered for site work and adds SD card logging.

Can the DM9600 measure SF₆?

Yes, as a non-flammable gas, at sample pressure up to 4 barg.

Can it be used for natural gas or other flammable gases?

No. YORK chilled mirror hygrometers are low-pressure instruments (up to 4 barg) and are not explosion-proof; they are for non-flammable gases in safe areas. For natural gas, see the DPT990-EX.

How do I get a quotation in the UAE?

Email dubai@yorkinstrument.com or WhatsApp +971 55 137 4866 with the gases, dew point range and quantity.