Gas storage, CNG and biomethane: where to measure moisture, O₂ and CO₂
Three places where gas re-enters a network or a vehicle: storage withdrawal, CNG dispensing and biomethane injection. Each numbered point shows what is measured, the typical limit and the analyzer that fits.
Tap a numbered point. Swipe the diagram sideways on a phone.
How the process works
Each of these processes hands gas to someone else: back to the pipeline operator, to a vehicle, or into the gas grid. The handover point is where moisture, oxygen and CO₂ are checked against a written limit.
- Storage injection. Pipeline gas is compressed into a depleted field or aquifer, where it picks up water and sometimes heavier hydrocarbons.
- Storage withdrawal. Withdrawn gas passes a separator and is dried, usually with TEG, before it goes back to the pipeline.
- CNG station. Distribution gas is dried, compressed to vehicle storage pressure, held in a cascade and dispensed.
- Biogas upgrading. Membranes or pressure-swing adsorption remove CO₂ and water from biogas to make biomethane.
- Grid entry. A grid entry unit checks the biomethane against the network entry limits, then odorizes and meters it.
Measurement points at a glance
| # | Point | Measures | Typical value / limit | Recommended solution |
|---|---|---|---|---|
| 1 | Storage withdrawal, after dehydration | Water dew point at line pressure | Example network limit −7 °C at 4 MPa; TEG dehydration reaches about −10 °C | DPT830, DPT990-EX, DPSS-61XX, DPT-600 Plus-EX |
| 2 | Storage withdrawal, after dehydration | Hydrocarbon dew point | Per the network specification (see the natural gas map) | Integrated system: hydrocarbon dew point analyzer or process GC |
| 3 | CNG station dryer outlet | Water dew point at storage pressure | At least 10 °F (5.6 °C) below the 99.0 % winter design temperature, at storage-container pressure (California, tested per ASTM D1142) | DPT830, DPT990-EX, DPT-600 Plus-EX |
| 4 | CNG storage / dispenser | Oxygen (%) | ≤ 1.0 mol % (California CNG specification) | Integrated system: paramagnetic O₂ analyzer certified for the hazardous area |
| 5 | CNG dispenser | CO₂ (inerts) | CO₂ + N₂ ≤ 4.5 % (California CNG specification) | Integrated system: CO₂ analyzer certified for the hazardous area |
| 6 | Biomethane grid entry | Oxygen | EN 16726: 10 ppm for sensitive users (24 h average); UK: ≤ 0.2 % above 38 barg, ≤ 1.0 % at or below; Spain: 0.01 mol %, relaxable to 1 mol % in some networks | PGA500, PGA530, POA200 |
| 7 | Biomethane grid entry | CO₂ (%) | UK: ≤ 2.0 mol %; Spain: 2.5 mol %, relaxable to 4 mol % in some networks | Integrated system: NDIR CO₂ analyzer with a 0–5 mol % range in the grid-entry unit |
| 8 | Biomethane grid entry | Water dew point | UK: −10 °C at 7 barg for systems below 7 barg, up to −10 °C at 85 barg for systems above 16 barg | DPT810 |
| 9 | Biomethane grid entry | H₂S, heating value and Wobbe index | UK entry: H₂S ≤ 5 mg/m³; heating value calculated per ISO 6976 | Integrated system: H₂S analyzer and process GC for heating value and Wobbe index |
Values are typical figures from published specifications and technical literature. Your contract, licensor or plant specification always governs.
Getting reliable readings
- Pressure basis. Storage and CNG dew points are specified at line or storage pressure. Convert with ISO 18453 and always state the pressure.
- Glycol and compressor oil. Filter the sample at TEG outlets and after reciprocating compressors.
- Local rules. Limits differ by country and network operator. In the GCC, take them from the operator's specification.
References
- Dehydration of gas from underground storage (Inż. Ap. Chem. 2010)BazTech
- Natural gas vehicle fuel regulations, Chapter 6California Department of Food and Agriculture
- EASEE-gas CBP Hydrogen Quality Specification, additional material (EN 16726 limits)ENTSOG
- Network Entry Gas Quality SpecificationCadent Gas
- Gas qualityEnagás
- WG_GQ-187 gas quality comparisonMarcogaz
- EMIB Appendix 7: Specification of water dew temperature of biomethaneGas Governance UK
- ISO 18453:2004 Natural gas: correlation between water content and water dew pointISO
- ISO 6976:2016 Natural gas: calculation of calorific values, density and Wobbe indicesSIS
Frequently asked questions
Why is gas dried after underground storage?
The reservoir saturates the gas with water. Withdrawn gas must be dried, usually by TEG, to the pipeline water dew point before it re-enters the network.
What water dew point does CNG need?
California requires the water dew point at storage-container pressure to be at least 10 °F below the 99.0 % winter design temperature. Other markets set their own limits.
What oxygen limit applies to biomethane injection?
It depends on the network: EN 16726 recommends 10 ppm where sensitive users are connected, UK entry allows 0.2 % above 38 barg and 1.0 % below, and some networks allow up to 1 mol %.
Planning a storage, CNG or biomethane project?
Send us the points, pressures and limits, and we will propose the analyzers and sampling systems.