Gas-to-liquids and methanol: where to measure moisture, oxygen and CO₂

Follow the natural gas through desulfurisation and the reformer into methanol or Fischer–Tropsch synthesis, and out to storage. Each numbered point shows what is measured, the typical value, why it matters and the instrument that fits.

FEED GASSYNGASSYNTHESISPRODUCTSUTILITIESNATURAL GASO₂ FROM ASUCO₂ IMPORTKNOCK-OUTDESULFURISATIONREFORMER (ATR)WASTE HEAT BOILERCOMPRESSORMETHANOLFISCHER–TROPSCHDISTILLATIONMeOHGTLN₂INSTRUMENT AIR1H₂O2S3O₂ %4H₂·CO5CO₂ %6O₂7H₂O8H₂O9O₂
YORK instrumentIntegrated system (supplied through YORK)

Tap a numbered point. Swipe the diagram sideways on a phone.

Request a quote for this point →
Auto tour
Project list 0 →

How the process works

Gulf gas producers turn natural gas into methanol and, in gas-to-liquids plants, into synthetic fuels and waxes. Both routes start with clean feed gas and oxygen-blown reforming, and both depend on moisture and oxygen control in the utilities.

  1. Feed treatment. Natural gas is cleaned of liquids and its sulfur is removed.
  2. Reforming. An autothermal reformer, fed with oxygen from an air separation unit and steam, converts the gas to syngas (H₂ and CO).
  3. Heat recovery and compression. A waste heat boiler cools the syngas and a compressor raises it to synthesis pressure.
  4. Synthesis. A methanol converter makes crude methanol; in a GTL plant, Fischer–Tropsch reactors turn syngas into liquid hydrocarbons.
  5. Products. Methanol is distilled to specification and stored under a nitrogen blanket; GTL liquids are upgraded and stored.
  6. Utilities. Nitrogen and instrument air serve the whole site.

Measurement points at a glance

#PointMeasuresTypical value / limitRecommended solution
1Natural gas feedWater dew pointSet by the gas supply contract; checked at the plant battery limitDPT990-EX
2Desulfurisation outletTotal sulfur (H₂S and organic sulfur)Removed to very low levels to protect the reforming, methanol and Fischer–Tropsch catalysts; the limit comes from the licensorSulfur analyzer (gas chromatograph or UV fluorescence)
3Oxygen to the reformerOxygen purity (%)High-purity oxygen from the air separation unit; the purity is set by the licensor and the ASU designPOA3500, PGA530
4Reformer outlet syngasH₂, CO, CO₂ and CH₄ slipComposition set by the reformer design; methane slip shows reformer performanceProcess gas chromatograph
5Methanol make-up gasCO₂ content (%)Methanol needs a syngas module M = (H₂ − CO₂)/(CO + CO₂) of about 2, in practice slightly above 2 (typically 2.05); CO₂ import adjusts itPGA520
6Nitrogen headerOxygen in purge and blanketing nitrogenSet by the site's purge and catalyst-handling proceduresPGA530, POA300, POA200
7Instrument airPressure dew pointISO 8573-1 Class 2 (≤ −40 °C) is a common choice for instrument airDPT810, DPT-600 Plus
8Methanol productWater in methanolIMPCA: water ≤ 0.100 % w/w (ASTM E 1064), purity ≥ 99.85 % w/w dry basisKarl Fischer titrator (laboratory)
9Methanol storage tankOxygen in the nitrogen blanketKept below the limiting oxygen concentration in the site's inerting designPGA530, POA300

Values are typical figures from published specifications and technical literature. Your contract, licensor or plant specification always governs.

Getting reliable readings

  • Hazardous areas. Most points are in classified areas: use explosion-proof analyzers or sample systems to an analyzer house.
  • Oxygen service. Use oxygen-clean sample systems on the oxygen line to the reformer.
  • Gas versus liquid. Measure moisture in gases with YORK analyzers; test liquid methanol in the laboratory.
  • Link to the ASU. Most GTL and methanol plants have their own air separation unit; see the ASU map for its measurement points.

References

  1. IMPCA Methanol Reference Specifications (July 2021)International Methanol Producers and Consumers Association / Methanol Institute
  2. US 10,308,576 Method for methanol synthesis (definition of the syngas module)U.S. Patent and Trademark Office
  3. Gasifipedia: Commercial OxygenU.S. DOE National Energy Technology Laboratory

Frequently asked questions

What is measured in a methanol plant?

Water in the natural gas feed, sulfur after desulfurisation, oxygen purity to the reformer, syngas composition and CO₂ for the module, oxygen in purge and blanketing nitrogen, instrument air dew point, and water in the methanol product.

What is the syngas module for methanol?

M = (H₂ − CO₂)/(CO + CO₂). Methanol needs about 2; plants run slightly above 2, typically 2.05, to allow for the purge.

Can YORK measure water in liquid methanol?

No. Water in liquid methanol is tested by Karl Fischer titration in the laboratory. YORK analyzers measure moisture and oxygen in gases.