Direct reduced iron and EAF steel: where to measure moisture, O₂ and CO₂

Follow the gas from natural gas desulfurisation through the reformer and shaft furnace to the seal gas and the electric arc furnace. Each numbered point shows what is measured, the typical value, why it matters and the analyzer that fits.

NATURALGASTOP GAS RECYCLEO₂REDUCING GASN₂OFF-GASDESULF.PROCESS GASCOMPRESSORREFORMERHEAT RECOVERYSEAL GASCOOL · COMPRESS · DRYSHAFT FURNACETOP GASSCRUBBERHBI / DRIEAF1H₂O2H₂S3CO₂4O₂5H₂/CO6CO₂7GC8O₂9H₂O10O₂11CO·O₂12O₂ %
YORK instrumentIntegrated system (supplied through YORK)

Tap a numbered point. Swipe the diagram sideways on a phone.

Request a quote for this point →
Auto tour
Project list 0 →

⤓ Download the 2-page PDF application note

How the process works

A natural-gas direct reduction plant turns iron ore pellets into DRI or HBI with a hot H₂/CO gas, and the electric arc furnace melts it into steel. Gas quality decides metallisation and energy use at every step. In the GCC, EMSTEEL runs HYL/Energiron-type modules, Hadeed and Jindal Shadeed (Sohar) run MIDREX-type modules, and the Duqm project uses a hydrogen-ready HYL/Energiron-type plant.

  1. Desulfurisation. Natural gas is cleaned to a narrow sulfur window: enough to stop carbon deposits in the reformer, not so much that the catalyst is poisoned.
  2. Reforming. Recycled top gas and natural gas are compressed, preheated and reformed over nickel catalyst. CO₂ and H₂O in the feed are the oxidants. HYL/Energiron-type plants reform inside the shaft instead.
  3. Reduction. Hot reducing gas, often boosted with oxygen injection, enters the shaft furnace at the bustle and reduces the iron ore.
  4. Top gas recycle. Spent top gas is scrubbed, cooled and split into recycle process gas and reformer fuel. HYL/Energiron-type plants remove CO₂ with amine.
  5. Seal gas and inerting. Dried flue gas or nitrogen seals the furnace and protects hot DRI and HBI from re-oxidation.
  6. Electric arc furnace. DRI or HBI is melted. Off-gas analysis controls post-combustion and detects water leaks.

Measurement points at a glance

#PointMeasuresTypical value / limitRecommended solution
1Natural gas at the plant battery limitWater dew point at line pressurePer the gas supply contract (no published limit for GCC plant supplies)DPT990-EX
2Desulfurised gas to the reformerH₂S / total sulfur (ppmv)Window of 2–5 ppmv in reformer feed (MIDREX-type). Raw associated gas has run 350–600 ppmv at one plantIntegrated system: ppm-level H₂S / total sulfur analyzer (GC with sulfur detector or UV)
3Reformer feed gas (top gas + natural gas)CO₂ (%)About 15 % CO₂ (with ~13 % H₂O) in typical MIDREX-type feed gasDPSS-61XX; Integrated system: NDIR CO₂ analyzer in a purged analyzer shelter
4Reformer flue gasExcess O₂ (%)1–2 % O₂; flue gas is roughly N₂ 60–65 %, CO₂ 15–18 %, H₂O 20–22 %POA3500, DPSS-61XX, POA300, PGA530
5Reformed (bustle) gasH₂, CO, CO₂, H₂O, CH₄ and quality ratioQuality (H₂+CO)/(H₂O+CO₂) ≥ 9.5; typical H₂ 55 %, CO 35 % (MIDREX-type). HYL/Energiron-type gas runs H₂/CO 3–5Integrated system: process gas chromatograph or mass spectrometer
6Bustle gas to the shaft furnaceCO₂ (%)About 2 % in typical reformed gas; 2.8 % reported at one plantDPSS-61XX; Integrated system: NDIR CO₂ analyzer with a low-percent range, in a purged analyzer shelter
7Top gas leaving the furnaceH₂, CO, CO₂, CH₄Measured at one plant: H₂ 37 %, CO 19 %, CO₂ 14 %, H₂O 21 %Integrated system: process gas chromatograph or mass spectrometer
8Seal (inert) gas from reformer flue gasO₂ (%)Source flue gas below 2 % O₂; seal-gas specification set by the licensorPOA3500, POA300, PGA530, PGA500-EX
9Dry seal gas after the dryerDew pointSet by the licensor's seal-gas specificationDPT810, DPT830
10Nitrogen header for inerting (HYL/Energiron-type)O₂ and dew pointN₂ use of about 12 (cold DRI) to 19 Nm³/t (HBI); purity per plant specificationPGA500, POA200, DPT830
11EAF off-gas after the elbowCO, CO₂, O₂, H₂ (H₂O for water leaks)One control scheme keeps the CO/O₂ ratio between 0.40 and 0.75Integrated system: water-cooled extractive probe with NDIR / paramagnetic / thermal-conductivity analyzers, or in-situ laser (TDLAS)
12Oxygen for bustle-gas injection and EAF lancingO₂ purity (%)> 99.5 % from cryogenic air separation; < 95 % from VPSAPOA3500

Values are typical figures from published specifications and technical literature. Your contract, licensor or plant specification always governs.

Getting reliable readings

  • Dry basis. Reformer and bustle gases carry several percent water. Condition the sample and report CO₂ and O₂ on a dry basis, or use a fully heated line.
  • Hot, dusty, flammable gas. Top gas, bustle gas and EAF off-gas need cooled or blow-back probes, fast loops and certified analyzer cabinets.
  • Seal gas is a safety loop. Its O₂ and dew point decide whether hot DRI re-oxidises and whether the seal legs stay non-flammable.
  • Many points are integrated systems. Gas chromatographs, sulfur analyzers and EAF off-gas systems are supplied as integrated systems together with YORK dew point, O₂ and CO₂ instruments.

Frequently asked questions

Which gas measurements matter most in a DRI plant?

Sulfur in the reformer feed, CO₂ and H₂O in the feed and reducing gas, reformer flue gas O₂, and the O₂ and dew point of the seal or inert gas that protects hot DRI.

What is the bustle gas quality ratio?

It is (H₂+CO)/(H₂O+CO₂), the reducing gases divided by the oxidising gases. MIDREX-type plants keep it at 9.5 or higher.

Why measure the seal gas?

Seal gas keeps reducing gas in the furnace and air out. Too much oxygen or moisture re-oxidises hot DRI and can create a flammable mixture at the seal legs.

Can YORK supply the gas chromatographs and EAF off-gas systems?

YORK supplies them as integrated systems through its partner integration factory, together with YORK dew point, oxygen and CO₂ analyzers.