Atmospheric dew point
The dew point of a gas after it is expanded to atmospheric pressure. It is lower than the pressure dew point of the same gas. More →
C
Chilled mirror hygrometer
Cools a mirror until dew or frost forms and holds the film steady; the mirror temperature is the dew point. A fundamental, drift-free method used as a reference. More →
Cricondentherm
The highest temperature at which liquid hydrocarbons can condense from a gas at any pressure. Hydrocarbon dew point specifications often refer to it. More →
D
Dew point
The temperature at which water vapour in a gas starts to condense as liquid at a given pressure. A lower dew point means a drier gas. More →
Dry-down
The time a sample line and sensor take to reach a stable reading after exposure to wetter gas or air. Short, clean, electropolished lines dry down fastest. More →
E
Electrochemical oxygen cell
Oxygen diffuses through a membrane and is reduced at a cathode; the cell current is proportional to the oxygen partial pressure. Suited to trace ppm levels. More →
F
Frost point
Below 0 °C, water vapour deposits as ice rather than dew. The frost point is the temperature at which this happens; it is slightly higher than the dew point over supercooled water. More →
G
Gas chromatograph (GC)
Separates a gas sample into its components in a column and measures each one. Used for natural gas composition, heating value and trace impurities. More →
H
Hazardous area (Zone 0, 1, 2)
An area where flammable gas may be present: Zone 0 continuously, Zone 1 in normal operation, Zone 2 only abnormally. Instruments there need explosion protection. More →
Hydrocarbon dew point (HCDP)
The temperature at which heavy hydrocarbons start to condense from natural gas at a given pressure. It is measured or calculated separately from the water dew point. More →
L
lb/MMscf
Pounds of water per million standard cubic feet of gas, the usual US unit for water in natural gas. 7 lb/MMscf is about 147 ppmv. More →
LOC (limiting oxygen concentration)
The oxygen level below which a fuel–air–inert mixture cannot burn. Inerting keeps oxygen a safe margin below the LOC. More →
M
Metal-oxide (aluminium oxide) sensor
A thin porous oxide film whose capacitance changes as water molecules enter its pores. It reaches very low frost points and responds quickly, suiting continuous monitoring. More →
mg/m³ (water content)
Mass of water per cubic metre of gas, used for example in breathing-air rules. At 1 atm, 50 mg/m³ of water is about 67 ppmv. More →
N
NDIR (non-dispersive infrared)
Measures how much infrared light a gas absorbs at its characteristic wavelength — 4.26 µm for CO₂ — with a reference channel to cancel lamp and window changes. More →
P
Paramagnetic oxygen analyzer
Uses oxygen's strong attraction to a magnetic field to measure percent-level O₂, with no consumable cell. More →
ppmV vs ppmW
Parts per million by volume (mole) or by weight (mass). For water in a gas they differ by the ratio of molar masses, so always state which one a limit uses. More →
Pressure dew point (PDP)
The dew point of a gas at its actual line pressure. Compressed air classes and pipeline specifications are set as pressure dew points. More →
R
Relative humidity (RH)
Water vapour pressure as a percentage of the saturation pressure at the same temperature. It changes with temperature, so dry process gases are specified by dew point instead. More →
S
Sample conditioning / fast loop
The pressure reduction, filtration, heat tracing and bypass flow that deliver a representative sample quickly to the analyzer. More →
Span and zero gas
Certified reference gases used to check an analyzer: zero gas contains none of the measured component, span gas a known amount near the top of the range. More →
T
TDLAS (tunable diode laser absorption spectroscopy)
A laser scans a single absorption line of the target molecule. It is used for moisture in streams with glycol, methanol or HCl that affect contact sensors. More →
Thermal conductivity detector (TCD)
Measures how well a gas conducts heat. Hydrogen conducts far better than other gases, so TCD is used for H₂ purity, e.g. in hydrogen-cooled generators. More →
W
Wobbe index
Calorific value divided by the square root of relative density. Gases with the same Wobbe index deliver the same heat through a burner. More →
Z
Zirconia oxygen probe
A heated zirconia cell whose voltage depends on the oxygen ratio across it. Used in situ for combustion O₂ in flue gas and for furnace atmospheres. More →
No matching term.
Frequently asked questions
What is the difference between dew point and frost point?
Both are the temperature at which water vapour condenses. Below 0 °C it forms ice rather than liquid water, and that temperature is called the frost point.
What is the difference between pressure dew point and atmospheric dew point?
Pressure dew point is measured at the gas's line pressure; atmospheric dew point refers to the same gas expanded to 1 atm. The same gas has a higher dew point at higher pressure.
Is ppmV the same as ppmW?
No. ppmV is by volume (mole fraction) and ppmW by mass. For water in a gas the two differ by the ratio of molar masses, so a specification must say which it uses.
Have a question about a measurement?
Ask our engineers about your gas, range and measuring point.