| Standard / document | Scope | Key moisture, O₂ and CO₂ limits | Where it applies | See also |
|---|---|---|---|---|
| ISO 8573-1:2010 Compressed air | Compressed air purity classes for particles, water and oil. | Water by pressure dew point: Class 1 ≤ −70 °C, 2 ≤ −40 °C, 3 ≤ −20 °C, 4 ≤ +3 °C, 5 ≤ +7 °C, 6 ≤ +10 °C. Oil: Class 1 ≤ 0.01, 2 ≤ 0.1, 3 ≤ 1, 4 ≤ 5 mg/m³. | Plant air, dryer outlets, quality audits. | |
| ISA-7.0.01 (instrument air) Compressed air | Quality of air for pneumatic instruments. | Pressure dew point at least 10 °C below the lowest ambient temperature and never above +4 °C at line pressure; oil ≤ 1 ppm w/w; particles ≤ 40 µm. | Instrument air headers in refineries and process plants. | |
| ISO 14687:2025 Grade D Hydrogen | Hydrogen fuel for PEM fuel-cell road vehicles. | H₂ ≥ 99.97 %; H₂O ≤ 5, O₂ ≤ 5, CO₂ ≤ 2, CO ≤ 0.2, total sulfur ≤ 0.004 µmol/mol. | Hydrogen refuelling stations, electrolyser product. | |
| EN 16726 Natural gas | European natural gas quality (group H). | Water dew point −8 °C at 70 bar(a); O₂ 10 ppm (24 h moving average) where sensitive users are supplied. | Cross-border and network entry points in Europe; reference for project specifications. | |
| US pipeline tariffs (practice) Natural gas | Gas quality sections of interstate pipeline tariffs. | Water ≤ 7 lb/MMscf (≈ 147 ppmv), some pipelines ≤ 4; example tariff: O₂ ≤ 0.2 vol %, CO₂ ≤ 2.0 vol %, total inerts ≤ 4.0 %. | Custody transfer in the US; often quoted in project specs. | |
| UK network entry (Cadent) Natural gas | Network entry gas quality specification, incl. biomethane. | Water dew point −10 °C at 85 barg (> 16 barg systems); hydrocarbon dew point ≤ −2 °C up to 85 bar; O₂ ≤ 0.2 % above 38 barg, ≤ 1.0 % at or below 38 barg; CO₂ ≤ 2.0 %; H₂S ≤ 5 mg/m³. | Gas and biomethane injection into UK grids. | |
| California CNG fuel specification Natural gas | Natural gas as a motor vehicle fuel. | Water dew point at storage pressure ≥ 10 °F (≈ 5.6 K) below the 99 % winter design temperature (tested by ASTM D1142); O₂ ≤ 1.0 mol %; CO₂ + N₂ ≤ 4.5 %. | CNG station dryers and dispensers. | |
| ISO 18453 Natural gas | Correlation between water content and water dew point of natural gas. | No limit: the method converts water content to dew point at a stated pressure. | Reporting dew point at line pressure from a ppmv or lb/MMscf reading. | |
| ISO 6976 Natural gas | Calculation of calorific values, density and Wobbe index from composition. | No limit: calculation method from the mole-fraction composition. | Energy billing at custody transfer; gas turbine fuel tuning. | |
| ISO 23874 Natural gas | Gas chromatograph requirements for calculating hydrocarbon dew point. | No limit: covers cricondentherms from 0 to −50 °C at 2–5 MPa. | Hydrocarbon dew point at custody transfer. | |
| ASTM D1142 · GB/T 17283 Natural gas | Test methods for water dew point of natural gas with a chilled (dew-point) mirror. | No limit: measurement method standards. | Reference and dispute measurements; CNG and pipeline specs cite them. | |
| IEC 62271-1 (SF₆ switchgear) Power / SF₆ | High-voltage switchgear common specifications, incl. SF₆ moisture criterion. | Reference criterion ≈ 574 ppmv at 700 kPa; equipment manufacturers set 70–1000 ppmv depending on compartment type. | In-service GIS and breaker compartments. | |
| CIGRE SF₆ re-use criteria (TB 723) Power / SF₆ | On-site measurement and re-use of SF₆. | Moisture 120 ppmv at 2 MPa, 320 ppmv at 500 kPa, 1600 ppmv at 100 kPa; air + CF₄ ≤ 2 %; decomposition products ≤ 50 ppmv for re-use. | Recovered SF₆ before refilling. | |
| IEC 60480 · IEC 60376 Power / SF₆ | Re-use (60480) and new-gas acceptance (60376) of SF₆. | See the standard — limits not reproduced here. | Gas handling and acceptance testing. | |
| GB/T 8979-2025 (nitrogen) Industrial & medical gases | Pure, high-purity and ultrapure nitrogen. | O₂ < 50 / < 3 / < 0.1 ppm; H₂O < 15 / < 3 / < 0.5 ppm (pure / high-purity / ultrapure). | Air separation product, cylinder filling, N₂ generators. | |
| Pharmacopoeia: medical air and oxygen Industrial & medical gases | Monographs for medicinal gases (Brazilian Pharmacopoeia 7th ed.). | Medical air: H₂O ≤ 67 ppm, O₂ 19.5–23.5 %, CO₂ ≤ 500 ppm, CO ≤ 5 ppm, SO₂ ≤ 1 ppm, NO + NO₂ ≤ 2 ppm, oil ≤ 0.1 mg/m³. Medical O₂ ≥ 99.0 %, H₂O ≤ 67 ppm, CO₂ ≤ 300 ppm. | Hospital medical air plants and oxygen supply. | |
| Breathing air (Norwegian regulation, Section 5-5) Compressed air | Quality of compressed breathing air. | O₂ 21 ± 0.5 %; CO₂ ≤ 500 ppm; CO ≤ 10 ppm; oil ≤ 1 mg/m³; water ≤ 50 mg/m³ for 200 bar or ≤ 30 mg/m³ for 300 bar fills. EN 12021: see the standard. | Breathing-air compressors and cylinder fill panels. | |
| NFPA 69 inerting margins (summary) Industrial & medical gases | Explosion prevention by oxidant concentration reduction. | With continuous O₂ monitoring: keep O₂ at least 2 percentage points below the LOC when LOC ≥ 5 %, or at ≤ 60 % of the LOC when LOC < 5 %. Approximate LOC in N₂: methane ≈ 12 %, H₂ ≈ 5 %. | Nitrogen blanketing of tanks and reactors, purging. | |
| ISBT beverage-grade CO₂ guideline CO₂ | Quality guideline for CO₂ used in beverages (4th revision, 2021). | CO₂ ≥ 99.9 %; H₂O ≤ 20 ppm v/v; O₂ ≤ 30 ppm v/v; CO ≤ 10 ppm v/v; total sulfur ≤ 0.1 ppm v/v. | CO₂ production, storage tanks and beverage fillers. | |
| NETL CO₂ impurity design parameters CO₂ | Design limits for captured CO₂ in pipelines, EOR and storage. | CO₂ ≥ 95 %; H₂O 500 ppmv; O₂ 10 ppmv (0.001 vol %); N₂ 1 % (EOR); H₂S 0.01 vol %; CO 35 ppmv. | CO₂ dehydration outlet and dense-phase pipelines. |
Values are taken from the published sources listed below. The official edition of each standard and your contract specification always govern.
How to use this reference
Most gas projects in the GCC set their limits in contracts or licensor specifications, but those build on the standards below. Use the table to find the reference number, then open the process map to see where it is measured.
References
- ISO 8573-1:2010 Compressed air — Contaminants and purity classesISO
- Understanding ISA-7.0.01-1996 Instrument Air StandardCompressed Air Best Practices
- Hydrogen Fuel Regulations (Sec. 4181)California Department of Food & Agriculture
- MetroHyVe / HYDRAITE: ISO TC197 hydrogen quality reportSINTEF
- EASEE-gas CBP Hydrogen Quality Specification, additional material (EN 16726 limits)ENTSOG
- Gas Quality section of the Algonquin FERC TariffMass.gov
- Draft Comparison of Pipeline Natural Gas Quality Specifications (R03035)NAESB
- Network Entry Gas Quality SpecificationCadent Gas
- Natural gas vehicle fuel regulations, Chapter 6California Department of Food & Agriculture
- ISO 18453:2004 Natural gas — Correlation between water content and water dew pointISO
- ISO 6976:2016 Natural gas — Calculation of calorific values, density, relative density and Wobbe indicesSIS
- ISO 23874:2006 Natural gas — GC requirements for hydrocarbon dewpoint calculationCSA Group
- GB/T 37124-2018 related standards (incl. GB/T 17283 chilled-mirror method)chinesestandard.net
- Giegel, SF₆ moisture presentation, IEEE PES Substations Committee WG K6 (2012)IEEE
- Bolin, SF₆ recycling and CIGRE limits (2000)US EPA archive
- TB 723 SF₆ Measurement GuideCIGRE
- GB/T 8979-2025 Pure nitrogen, high-purity nitrogen and ultrapure nitrogen (table preview)chinesestandard.net
- Farmacopeia Brasileira 7th ed., Vol. II — Medical GasesANVISA
- Regulations concerning action and limit values, Section 5-5 (breathing air)Norwegian Labour Inspection Authority
- Inerting, purging, discharge location and containment (NFPA 69 summary)Open Exam Prep
- QGESS: CO₂ Impurity Design Parameters (NETL-PUB-22529)US DOE NETL
Frequently asked questions
Which standard sets the water limit for compressed air?
ISO 8573-1 defines purity classes. For water, the class is set by the pressure dew point, from Class 1 (≤ −70 °C) to Class 6 (≤ +10 °C). Instrument air is often specified with ISA-7.0.01 instead.
What is the water specification for natural gas in the GCC?
GCC operators set the water dew point in their gas sales agreements, which are not published. European EN 16726 (−8 °C at 70 bar) and the US 7 lb/MMscf tariff practice are common references in project specifications.
Do ISO 18453 and ISO 6976 set limits?
No. ISO 18453 converts water content into water dew point at a given pressure, and ISO 6976 calculates calorific value and Wobbe index from the gas composition. The limits come from the contract or network code.
Why are IEC 60480 and IEC 60376 values not listed?
We list only figures we could verify against an openly published source. For these two SF₆ standards please refer to the current official edition.
Need an analyzer that meets one of these limits?
Tell us the standard, the gas and the measuring point, and we will propose the instrument.