Gas quality standards: quick reference for moisture, O₂ and CO₂

The standards and specifications that set moisture, oxygen and CO₂ limits, with their key numbers and the process maps and tools that apply them. Filter by industry.

Showing of 20 documents

Standard / documentScopeKey moisture, O₂ and CO₂ limitsWhere it appliesSee also
ISO 8573-1:2010
Compressed air
Compressed air purity classes for particles, water and oil.Water by pressure dew point: Class 1 ≤ −70 °C, 2 ≤ −40 °C, 3 ≤ −20 °C, 4 ≤ +3 °C, 5 ≤ +7 °C, 6 ≤ +10 °C. Oil: Class 1 ≤ 0.01, 2 ≤ 0.1, 3 ≤ 1, 4 ≤ 5 mg/m³.Plant air, dryer outlets, quality audits.
ISA-7.0.01 (instrument air)
Compressed air
Quality of air for pneumatic instruments.Pressure dew point at least 10 °C below the lowest ambient temperature and never above +4 °C at line pressure; oil ≤ 1 ppm w/w; particles ≤ 40 µm.Instrument air headers in refineries and process plants.
ISO 14687:2025 Grade D
Hydrogen
Hydrogen fuel for PEM fuel-cell road vehicles.H₂ ≥ 99.97 %; H₂O ≤ 5, O₂ ≤ 5, CO₂ ≤ 2, CO ≤ 0.2, total sulfur ≤ 0.004 µmol/mol.Hydrogen refuelling stations, electrolyser product.
EN 16726
Natural gas
European natural gas quality (group H).Water dew point −8 °C at 70 bar(a); O₂ 10 ppm (24 h moving average) where sensitive users are supplied.Cross-border and network entry points in Europe; reference for project specifications.
US pipeline tariffs (practice)
Natural gas
Gas quality sections of interstate pipeline tariffs.Water ≤ 7 lb/MMscf (≈ 147 ppmv), some pipelines ≤ 4; example tariff: O₂ ≤ 0.2 vol %, CO₂ ≤ 2.0 vol %, total inerts ≤ 4.0 %.Custody transfer in the US; often quoted in project specs.
UK network entry (Cadent)
Natural gas
Network entry gas quality specification, incl. biomethane.Water dew point −10 °C at 85 barg (> 16 barg systems); hydrocarbon dew point ≤ −2 °C up to 85 bar; O₂ ≤ 0.2 % above 38 barg, ≤ 1.0 % at or below 38 barg; CO₂ ≤ 2.0 %; H₂S ≤ 5 mg/m³.Gas and biomethane injection into UK grids.
California CNG fuel specification
Natural gas
Natural gas as a motor vehicle fuel.Water dew point at storage pressure ≥ 10 °F (≈ 5.6 K) below the 99 % winter design temperature (tested by ASTM D1142); O₂ ≤ 1.0 mol %; CO₂ + N₂ ≤ 4.5 %.CNG station dryers and dispensers.
ISO 18453
Natural gas
Correlation between water content and water dew point of natural gas.No limit: the method converts water content to dew point at a stated pressure.Reporting dew point at line pressure from a ppmv or lb/MMscf reading.
ISO 6976
Natural gas
Calculation of calorific values, density and Wobbe index from composition.No limit: calculation method from the mole-fraction composition.Energy billing at custody transfer; gas turbine fuel tuning.
ISO 23874
Natural gas
Gas chromatograph requirements for calculating hydrocarbon dew point.No limit: covers cricondentherms from 0 to −50 °C at 2–5 MPa.Hydrocarbon dew point at custody transfer.
ASTM D1142 · GB/T 17283
Natural gas
Test methods for water dew point of natural gas with a chilled (dew-point) mirror.No limit: measurement method standards.Reference and dispute measurements; CNG and pipeline specs cite them.
IEC 62271-1 (SF₆ switchgear)
Power / SF₆
High-voltage switchgear common specifications, incl. SF₆ moisture criterion.Reference criterion ≈ 574 ppmv at 700 kPa; equipment manufacturers set 70–1000 ppmv depending on compartment type.In-service GIS and breaker compartments.
CIGRE SF₆ re-use criteria (TB 723)
Power / SF₆
On-site measurement and re-use of SF₆.Moisture 120 ppmv at 2 MPa, 320 ppmv at 500 kPa, 1600 ppmv at 100 kPa; air + CF₄ ≤ 2 %; decomposition products ≤ 50 ppmv for re-use.Recovered SF₆ before refilling.
IEC 60480 · IEC 60376
Power / SF₆
Re-use (60480) and new-gas acceptance (60376) of SF₆.See the standard — limits not reproduced here.Gas handling and acceptance testing.
GB/T 8979-2025 (nitrogen)
Industrial & medical gases
Pure, high-purity and ultrapure nitrogen.O₂ < 50 / < 3 / < 0.1 ppm; H₂O < 15 / < 3 / < 0.5 ppm (pure / high-purity / ultrapure).Air separation product, cylinder filling, N₂ generators.
Pharmacopoeia: medical air and oxygen
Industrial & medical gases
Monographs for medicinal gases (Brazilian Pharmacopoeia 7th ed.).Medical air: H₂O ≤ 67 ppm, O₂ 19.5–23.5 %, CO₂ ≤ 500 ppm, CO ≤ 5 ppm, SO₂ ≤ 1 ppm, NO + NO₂ ≤ 2 ppm, oil ≤ 0.1 mg/m³. Medical O₂ ≥ 99.0 %, H₂O ≤ 67 ppm, CO₂ ≤ 300 ppm.Hospital medical air plants and oxygen supply.
Breathing air (Norwegian regulation, Section 5-5)
Compressed air
Quality of compressed breathing air.O₂ 21 ± 0.5 %; CO₂ ≤ 500 ppm; CO ≤ 10 ppm; oil ≤ 1 mg/m³; water ≤ 50 mg/m³ for 200 bar or ≤ 30 mg/m³ for 300 bar fills. EN 12021: see the standard.Breathing-air compressors and cylinder fill panels.
NFPA 69 inerting margins (summary)
Industrial & medical gases
Explosion prevention by oxidant concentration reduction.With continuous O₂ monitoring: keep O₂ at least 2 percentage points below the LOC when LOC ≥ 5 %, or at ≤ 60 % of the LOC when LOC < 5 %. Approximate LOC in N₂: methane ≈ 12 %, H₂ ≈ 5 %.Nitrogen blanketing of tanks and reactors, purging.
ISBT beverage-grade CO₂ guideline
CO₂
Quality guideline for CO₂ used in beverages (4th revision, 2021).CO₂ ≥ 99.9 %; H₂O ≤ 20 ppm v/v; O₂ ≤ 30 ppm v/v; CO ≤ 10 ppm v/v; total sulfur ≤ 0.1 ppm v/v.CO₂ production, storage tanks and beverage fillers.
NETL CO₂ impurity design parameters
CO₂
Design limits for captured CO₂ in pipelines, EOR and storage.CO₂ ≥ 95 %; H₂O 500 ppmv; O₂ 10 ppmv (0.001 vol %); N₂ 1 % (EOR); H₂S 0.01 vol %; CO 35 ppmv.CO₂ dehydration outlet and dense-phase pipelines.

Values are taken from the published sources listed below. The official edition of each standard and your contract specification always govern.

How to use this reference

Most gas projects in the GCC set their limits in contracts or licensor specifications, but those build on the standards below. Use the table to find the reference number, then open the process map to see where it is measured.

References

  1. ISO 8573-1:2010 Compressed air — Contaminants and purity classesISO
  2. Understanding ISA-7.0.01-1996 Instrument Air StandardCompressed Air Best Practices
  3. Hydrogen Fuel Regulations (Sec. 4181)California Department of Food & Agriculture
  4. MetroHyVe / HYDRAITE: ISO TC197 hydrogen quality reportSINTEF
  5. EASEE-gas CBP Hydrogen Quality Specification, additional material (EN 16726 limits)ENTSOG
  6. Gas Quality section of the Algonquin FERC TariffMass.gov
  7. Draft Comparison of Pipeline Natural Gas Quality Specifications (R03035)NAESB
  8. Network Entry Gas Quality SpecificationCadent Gas
  9. Natural gas vehicle fuel regulations, Chapter 6California Department of Food & Agriculture
  10. ISO 18453:2004 Natural gas — Correlation between water content and water dew pointISO
  11. ISO 6976:2016 Natural gas — Calculation of calorific values, density, relative density and Wobbe indicesSIS
  12. ISO 23874:2006 Natural gas — GC requirements for hydrocarbon dewpoint calculationCSA Group
  13. GB/T 37124-2018 related standards (incl. GB/T 17283 chilled-mirror method)chinesestandard.net
  14. Giegel, SF₆ moisture presentation, IEEE PES Substations Committee WG K6 (2012)IEEE
  15. Bolin, SF₆ recycling and CIGRE limits (2000)US EPA archive
  16. TB 723 SF₆ Measurement GuideCIGRE
  17. GB/T 8979-2025 Pure nitrogen, high-purity nitrogen and ultrapure nitrogen (table preview)chinesestandard.net
  18. Farmacopeia Brasileira 7th ed., Vol. II — Medical GasesANVISA
  19. Regulations concerning action and limit values, Section 5-5 (breathing air)Norwegian Labour Inspection Authority
  20. Inerting, purging, discharge location and containment (NFPA 69 summary)Open Exam Prep
  21. QGESS: CO₂ Impurity Design Parameters (NETL-PUB-22529)US DOE NETL

Frequently asked questions

Which standard sets the water limit for compressed air?

ISO 8573-1 defines purity classes. For water, the class is set by the pressure dew point, from Class 1 (≤ −70 °C) to Class 6 (≤ +10 °C). Instrument air is often specified with ISA-7.0.01 instead.

What is the water specification for natural gas in the GCC?

GCC operators set the water dew point in their gas sales agreements, which are not published. European EN 16726 (−8 °C at 70 bar) and the US 7 lb/MMscf tariff practice are common references in project specifications.

Do ISO 18453 and ISO 6976 set limits?

No. ISO 18453 converts water content into water dew point at a given pressure, and ISO 6976 calculates calorific value and Wobbe index from the gas composition. The limits come from the contract or network code.