Process guide · animated
Aluminium smelters: where to measure moisture, O₂ and CO₂
Follow the air, gas and metal from the compressor house and potline to the gas treatment centre, anode baking furnace and cast house. Each numbered point shows what is measured, the typical value, why it matters and the analyzer that fits.
Tap a numbered point. Swipe the diagram sideways on a phone.
⤓ Download the 2-page PDF application note
How the process works
The GCC is home to some of the world's largest primary aluminium smelters. Gas measurement there is less about the electrolysis itself and more about the systems around it: dry compressed air for the potline, the fluoride and carbon balance at the gas treatment centre, combustion in the baking and holding furnaces, and dry, clean degassing gas in the cast house.
- Compressed air. Compressors and dryers supply the point feeders, crust breakers and alumina conveying. Dry air keeps moisture out of the cells and the valves working.
- Potline. Alumina is reduced in the cells. Hydrogen from moisture in the alumina and air reacts with the bath to form HF.
- Gas treatment centre. Pot gas, diluted about a hundredfold with air, is scrubbed with fresh alumina and filtered. The stack is checked for HF, dust, SO₂ and PFCs.
- Carbon plant and anode baking. Green anodes are baked in a ring furnace; the pitch volatiles burn as fuel and the fumes are treated before the stack.
- Cast house. Metal from the holding furnace passes an in-line degasser, where argon or nitrogen strips hydrogen before casting.
- Nitrogen supply. A nitrogen generator or bulk tank feeds degassing, dross cooling and purging.
Measurement points at a glance
| # | Point | Measures | Typical value / limit | Recommended solution |
|---|---|---|---|---|
| 1 | Compressed air dryer outlet | Pressure dew point | Class chosen by the site under ISO 8573-1, e.g. Class 2 ≤ −40 °C or Class 1 ≤ −70 °C | DPT810, DPT830 |
| 2 | Potline air header (point feeders) | Pressure dew point at the point of use | As specified by the site | DPT810, DPT-600 Plus |
| 3 | Gas treatment centre stack / main duct | CO₂ (vol %) | 0.6–1.2 vol % in pot exhaust gas | Integrated system: NDIR CO₂ analyzer with a 0–2 vol % range |
| 4 | Gas treatment centre stack | HF and total fluoride | EU BAT-AEL: HF ≤ 1.0 mg/Nm³ (daily average), total F ≤ 1.5 mg/Nm³; GCC permits set their own limits | Integrated system: in-situ or extractive laser (TDL) HF analyzer |
| 5 | Pot gas duct / gas treatment centre | CF₄ and C₂F₆ (perfluorocarbons) | Low-voltage CF₄ about 0.01–1 ppmv; up to 0.5–10 ppmv during anode effects; detection limit needed ≤ 0.01 ppmv | Integrated system: extractive FTIR or quantum-cascade laser analyzer |
| 6 | Anode baking furnace flue (exhaust ramp) | O₂ (%) | Set by the furnace operator; high O₂ in the preheat zone signals air ingress | POA3500, DPSS-61XX |
| 7 | Fume treatment centre outlet | HF, dust, PAH | EU BAT-AEL (integrated plant): HF 0.3–0.5 mg/Nm³ (daily average) | Integrated system: laser (TDL) HF analyzer, dust monitor and periodic PAH sampling |
| 8 | Argon / nitrogen to the degasser | Dew point | As dry as possible; no neutral published limit at the point of use | DPT830, DPT-600 Plus, DM9600, DM9700 |
| 9 | Argon / nitrogen to the degasser | Trace O₂ (ppm) | Point-of-use limit set by the cast house | POA200, PGA500 |
| 10 | Holding / melting furnace flue | Excess O₂ (%) | General guidance for gas-fired furnaces: 2–3 % O₂ (10 % excess air ≈ 2.1 % O₂) | POA3500, POA300, PGA530 |
| 11 | Molten metal before casting | Dissolved hydrogen (mL/100 g) | Target < 0.15 mL/100 g in one plant study; porosity thresholds 0.1–0.2 mL/100 g | Integrated system: in-melt hydrogen probe or reduced-pressure test |
| 12 | Nitrogen generator outlet | Residual O₂ (ppm or %) | Purity set by the use: degassing, dross cooling or purging | POA200, PGA500, POA300, PGA530 |
Values are typical figures from published specifications and technical literature. Your contract, licensor or plant specification always governs.
Getting reliable readings
- Moisture is a hydrogen source. In the potline it feeds HF; in the cast house it feeds porosity. Dry compressed air and dry degassing gas protect both.
- HF and dust. Raw pot gas carries fluorides and alumina dust. Most raw-gas analyses are integrated laser or FTIR systems; YORK instruments measure the clean utility gases and the conditioned flue gases.
- Permits. GCC smelters work to national permit limits; the EU BAT values on this page are a reference only.
References
- Commission Implementing Decision (EU) 2016/1032: BAT conclusions for non-ferrous metals, aluminiumEU (legislation.gov.uk mirror)
- Same Decision, BAT 10 monitoringEU (legislation.gov.uk mirror)
- Good Practice Guidance: Measuring PerfluorocarbonsInternational Aluminium Institute
- D1.3 Recycling of the flue gas from aluminium electrolysis cells (HighEFF)SINTEF
- Selvaraj et al., Study of gibbsite effect on HF emission in aluminium reduction cells (2023)ICSOBA
- Nayak et al., Optimizing baking furnace performance and anode quality (2025)ICSOBA
- Tandon et al., Reduction of auxiliary energy consumption in an aluminium smelter (2024)ICSOBA
- Check burner air to fuel ratios, Process Heating Tip Sheet #2US DOE
- Tiryakioğlu, The effect of hydrogen on pore formation in aluminum alloy castings, Metals 10(3):368, 2020MDPI
- Akhtar et al., Measurement of dissolved hydrogen in Al alloys and hydrogen removal efficiency of a degassing system (2011)Pakistan Journal of Chemistry
Frequently asked questions
Why does compressed air dew point matter in a smelter?
Compressed air drives the point feeders, crust breakers and alumina conveying. Moisture it carries reaches the cells, where it is a hydrogen source for HF, and wet air also fails valves and cylinders.
Why must degassing argon or nitrogen be dry?
Water reacts with molten aluminium to release hydrogen, which dissolves in the metal. Wet degassing gas therefore adds the hydrogen it is meant to remove.
Which smelter measurements need integrated systems?
HF, PFCs, dust and SO₂ at the gas treatment and fume treatment centres, and dissolved hydrogen in the melt. YORK supplies them as integrated systems alongside its dew point, O₂ and CO₂ instruments.
Planning analyzers for a smelter?
Send us the measurement points, gas conditions and the parameters you need, and we will propose instruments and sampling systems.